• 제목/요약/키워드: current unbalance

검색결과 263건 처리시간 0.027초

Investigation and Implementation of a Passive Snubber with a Coupled-Inductor in a Single-Stage Full-Bridge Boost PFC Converter

  • Meng, Tao;Ben, Hongqi;Li, Chunyan;Wei, Guo
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.206-213
    • /
    • 2013
  • In this paper, an improved passive snubber is investigated in a single-phase single-stage full-bridge boost power factor correction (PFC) converter, by which the voltage spike across primary side of the power transformer can be suppressed and the absorbed energy can be transferred to the output side. When compared with the basic passive snubber, the two single-inductors are replaced by a coupled-inductor in the improved snubber. As a result, synchronous resonances in the snubber can be achieved, which can avoid the unbalance of the voltage and current in the snubber. The operational principle of the improved passive snubber is analyzed in detail based on a single-phase PFC converter, and the design considerations of both the snubber and the coupled-inductor are given. Finally, a laboratory-made prototype is built, and the experimental results verify the feasibility of the proposed method and the validity of the theoretical analysis and design method.

대용량 및 높은 입력전압에 적합한 새로운 Three Level DC/DC 컨버터 (A Novel Three Level DC/DC Converter for High power applications operating from High Input Voltage)

  • 한상규;오원식;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.317-322
    • /
    • 2003
  • A novel three-level DC/DC converter (TLC)for high power applications operating from high input voltage Is proposed. Its switch voltage stress can be ensured to be only one-half of the Input voltage. Nevertheless, since all input voltage is applied to the transformer primary side, it has good turns ratio. The driving method of each module is same as those of the conventional phase-shifted ZVS full bridge PWM converter (PSFB) and the zero-voltage-switching (ZVS) of the leading leg are achieved exactly in the same manner as that of the PSFB. Moreover, its three-level operation can considerably reduce the current ripple through the output inductor and it has no problems of the DC-link voltage unbalance. Therefore, it features a low voltage stress, high efficiency, low EMI, high power density, and small sized filter. To confirm the operation, validity, and features of the proposed circuit, experimental results from a 200W, 600V/DC-48V/DC prototype are presented.

  • PDF

154kV 주변압기 2차측 전력용 케이블 불평형 전류 저감 대책 (Measures to reduce the unbalance current of secondary power cable of 154kV main transformer)

  • 전상동;오장만;김기일;정규원;유희영;이봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.338_339
    • /
    • 2009
  • 송전전압을 배전전압으로 변성하여 고객에게 배분하는 154kV 주변압기의 경우 과거 옥외철구형 변전소에서는 주로 동을 이용한 모선을 이용하였다. 최근 부지확보의 어려움 및 빈번한 민원 발생으로 지하 또는 옥내변전소로 바뀌어 가는 추세이고 과거 동모선 방식에서 케이블을 이용한 방식이 선호되고 있다. 모선방식의 경우는 구리나 알루미늄 바의 부식문제, 습기문제, 그리고 좁은 공간에서 사용시 절연 문제 등과 관련하여 지속적인 관리가 요구되고 있으나 케이블을 사용할 경우 이러한 문제들로부터 벗어날 수 있는 이점을 가지고 있다. 그러나 케이블을 사용하여 대전류를 송전할 경우 단일 케이블의 허용전류 용량에 따른 제한으로 복수의 케이블을 병렬 연결하여 사용하여야 한다. 그러나 케이블 동상 병렬사용시 케이블 포설 방식에 따라 동상간의 불평형전류 차가 심하게 발생한다. 본 논문에서는 이러한 송 배전 선로의 불평형전류 현황을 알아보고, 송전선로에 있어서 상배열 변경 및 배전선의 동상 케이블 배열방법을 변경함으로써 불평형전류를 최소화 하여 최적의 계통상태 유지를 위한 방안을 찾고자 한다.

  • PDF

두 대의 LLT 변압기 적용 LLC 직렬 공진 컨버터 (LLC Series Resonant Converter with two Transformers)

  • 강성인;김주훈;김은수;박준호;허동영;정용채
    • 전력전자학회논문지
    • /
    • 제14권6호
    • /
    • pp.431-439
    • /
    • 2009
  • 본 논문에서는 두 대의 LLT 변압기 적용 LLC 직렬공진 컨버터의 입출력 이득 특성 및 설계과정에 대하여 서술 하였다. 적용된 두 대의 변압기 1차측은 직렬로 연결하고, 변압기 2차측은 병렬로 연결 하여 변압기 1차측 전류 불균형이 없도록 하였다. 부하 변동과 전압이득 특성을 고려하여 이론적 분석 및 시뮬레이션 결과를 토대로 50인치 PDP TV전원을 위한 400W 시제품을 제작 실험하여 설계 절차의 타당성을 검증하였다.

고속 버스트 모드 광 송신기에 적합한 자동 전력 제어 회로 (An Automatic Power Control Circuit suitable for High Speed Burst-mode optical transmitters)

  • 기현철
    • 대한전자공학회논문지SD
    • /
    • 제43권11호
    • /
    • pp.98-104
    • /
    • 2006
  • 기존의 버스트 모드 자동전력제어 회로는 저 전력과 단일 칩화에 적합한 효율적인 구조인 반면에 데이터 율(data rate)이 높아짐에 따라 영의 밀도(zero density) 영향을 심하게 받아 에러를 야기하였다. 본 논문에서는 더블 게이트 MOS와 MOS다이오드를 이용하여 주입전류의 불균형을 보상하는 할 수 있는 새로운 구조의 첨두 비교기를 고안하고 이를 자동전력제어 회로에 적용하여 높은 데이터 율에서도 영의 밀도 변화에 강한 버스트 모드 자동전력제어 회로를 제안하였다. 제안한 자동전력제어 회로 내의 첨두 비교기는 높은 데이터 율에서 영의 밀도 변화에도 불구하고 정확한 전류비교 기준점을 견지하며 에러 없이 정상동작 하였다. 또한 제안한 첨두 비교기는 저전력 구조이고 대용량의 커패시터가 사용되지 않아 단일 칩화에도 적합하였다.

Fault Diagnosis Method of Voltage Sensor in 3-phase AC/DC PWM Converters

  • Kim, Hyung-Seop;Im, Won-Sang;Kim, Jang-Mok;Lee, Dong-Choon;Lee, Kyo-Beum
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.384-390
    • /
    • 2012
  • This paper proposes a fault diagnosis method of the line-to-line voltage sensors in 3-phase AC/DC pulse width modulation (PWM) converters. The line-to-line voltage sensors are an essential device to obtain the information of the grid voltages for controlling the 3-phase AC/DC PWM converters. If the line-to-line voltage sensors are mismeasured by various faults, the voltage sensors can obtain wrong information of the grid voltage. It has an adverse effect on the control of the converter. Therefore, the converter causes the unbalance input AC current and the DC-link voltage ripple in the 3-phase AC/DC PWM converter. Hence, fast fault detection and fault tolerant control are needed. In this paper, the fault diagnosis method is proposed and verified through simulations and experiments.

FACTS 적용을 위한 직렬형 멀티레벨 전압형 인버터를 사용한 1MVar STATCON의 새로운 스위칭기법 (Novel Switching Strategy of 1MVar STATCON using Cascade Multilevel Voltage Source Inverter for FACTS Application)

  • 민완기;민준기;최재호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권12호
    • /
    • pp.691-700
    • /
    • 1999
  • This paper proposes a novel switching strategy of 1Mvar STATCON using cascade multilevel H-bridge inverter(HBI) for FACTS application. To control the reactive power instantaneously, the d-q dynamic system model is described and analyzed. A single pulse pattern based on the SHEM(Selective Harmonic Elimination Method) technique is determined from the look-up table to reduce the line current harmonics and a rotating fundamental frequency switching scheme is presented to adjust the DC voltage of each inverter capacitor at the same value. So the voltage unbalance problem between separately DC bus voltage is improved by using the proposed switching scheme. As a result, the presented inverter configuration not only reduces the system complexity by eliminating the isolation at the AC input side transformer but also improves the dynamic response to the step change of reactive power.

  • PDF

슬라이딩 모드 기반의 직접전력제어를 이용한 계통연계형 풍력발전 시스템의 LVRT 제어 (LVRT control of Grid-Connected Wind Turbine Using Sliding-Mode Based Direct Power Control)

  • 정해광;이교범
    • 전력전자학회논문지
    • /
    • 제16권4호
    • /
    • pp.396-404
    • /
    • 2011
  • 본 논문은 불평형 전원사고 발생 시 계통연계형 풍력발전 시스템의 성능 개선을 위한 슬라이딩모드 기반의 직접전력제어기법을 제안한다. 제안하는 제어기법은 전류의 좌표변환 없이 시스템의 유, 무효 전력을 직접 제어함으로써 계통사고 시 빠른 응답특성을 가지고 별도의 동기위상각 정보를 필요로 하지 않으며, 불평형 사고 시 계통주파수의 2배에 해당하는 전력 리플이 발생하지 않으므로 계통연계형 풍력발전 시스템 제어에 적합하다. 시뮬레이션 및 실험 결과를 통해 제안하는 제어기법의 타당성과 강인성을 확인한다.

전기자동차용 전지관리장치의 전지잔존량 연산알고리즘에 관한 연구 (A Study for BMS Operation Algorithm of Electric Vehicles)

  • 이재문;최욱돈;이종필;이종찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.114-117
    • /
    • 2001
  • In the Electric Vehicle(EV) driving system, the Battery Management System(BMS) is very important and an essential equipment. Particularly, BMS monitors the State of Charge(SOC), voltage, current, and temperature of the battery modules when Electric Vehicle is in the state of motoring or charging. Major roles of BMS are like these the first, estimation of State of Charge(SOC), the second, detection of the unbalance of the voltage between battery modules, the third, control of the available limit of the voltage and temperature of batteries by monitoring the batteries status during motoring or charging. In this research, We have focused on estimating SOC of battery according to the status of Electric Vehicle and the BMS operation algorithm. The result for algorithm of SOC estimation is presented. It have been modified, compensated, and verified by means of the experiment.

  • PDF

ESS 연계용 변압기의 결선방식 및 철심구조에 따른 순환전류와 포화특성에 관한 연구 (Characteristics of Saturation and Circulating Current Based on Winding and Iron Core Structure of Grid-connected Transformer in Energy Storage System)

  • 태동현;이후동;김지명;노대석
    • 한국산학기술학회논문지
    • /
    • 제21권4호
    • /
    • pp.39-48
    • /
    • 2020
  • 2017년 8월에 발생한 고창 전력시험센터를 시작으로, 현재까지 총 29건의 전기저장장치 화재가 발생하여 많은 재산피해가 보고되고 있다. 이에 대한 원인은 아직 정확하게 규명되지 않았으나, ESS(energy storage system)와 전력변환장치뿐만 아니라, 계통측 불평형 문제도 하나의 원인으로 고려되어야 할 것으로 보인다. 특히, 연계용변압기측의 순환전류가 자화전류에 영향을 미쳐, 의도치 않게 변압기의 철심이 포화되고 서지전압이 발생하여 ESS에 영향을 줄 수 있다. 따라서, 본 논문에서는 부하불평형에 의한 불평형전류 발생시, ESS 연계용변압기로 순환전류의 유입과 변압기 포화로 인한 서지전압 발생 현상을 해석하기 위하여, PSCAD/EMTDC를 이용한 배전용변전소, 연계용변압기 및 수용가부하로 구성된 배전계통의 모델링을 수행한다. 또한, 이러한 문제를 해결하기 위하여, 중성점 접지 저항기(neutral grounding resistor, NGR)를 통해 순환전류의 크기를 일정 값 이내로 저감시키는 방안을 제시하였다. 이를 바탕으로 시뮬레이션을 수행한 결과, 연계용변압기의 결선방식 및 철심구조에 따라 일정 값(10[A]) 이상의 순환전류가 발생하여, ESS에 전기적인 위해 요인이 될 수 있음을 알 수 있었고, 변압기 포화로 인해 2차측에 최대 3[pu]의 서지전압이 발생될 수 있음을 확인하였다.