• Title/Summary/Keyword: current pulse

Search Result 1,869, Processing Time 0.024 seconds

285 mJ Electro-optically 𝚀-switched Er:YAG Master Oscillator Power Amplifier (MOPA) System with Adjustable Pumping Delay between Flashlamps at 2.94 ㎛

  • Heesuk Jang;Hajun Song;Hae Seog Koh;Han Young Ryu
    • Current Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.297-303
    • /
    • 2023
  • In this paper, we demonstrated a high-energy (285 mJ) mid-infrared flashlamp-pumped electro-optically 𝚀-switched Er:YAG master oscillator power amplifier (MOPA) system and comprehensively investigated its temporal, spectral, and spatial characteristics. To increase the output energy, we optimized the delay between the timings at which the flashlamps of the master oscillator and power amplifier were triggered. In addition, the output energy was improved while minimizing thermal effects by cooling the MOPA system to a temperature slightly above the dew point. Consequently, the MOPA structure boosted the output energy without damaging the lithium niobate Pockels cell, which is a crucial element in 𝚀-switching. This design realized pulses with energies up to 0.285 J and pulse durations of approximately 140 ns at a wavelength of 2,936.7 nm. This high-energy mid-IR Er:YAG MOPA system can be used for various scientific, engineering, and military underwater applications.

Quench Analysis and Operational Characteristics of the Quench Detection System for the KSTAR PF Superconducting Coils (펄스전류 운전에 따른 KSTAR PF 초전도자석의 퀜치 분석 및 퀜치 검출 시스템 운전 특성)

  • Chu, Y.;Yonekawa, H.;Kim, Y.O.;Park, K.R.;Lee, H.J.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.20-25
    • /
    • 2009
  • The quench detection system of the KSTAR (Korea Superconducting Tokamak Advanced Research) primarily uses the resistive voltage measurement due to a quench. This method is to detect the resistive voltage generated by a quench, which is continuously maintained above the preset voltage threshold for a given holding time. As the KSTAR PF (Poloidal Field) coils are operated in the pulse current mode, the large inductive voltages are generated. Therefore the voltage threshold and the quench holding time should be determined by considering both the inductive voltages measured during the operation, and the maximum conductor temperature rise through the quench analysis. In this paper, the compensation methods for minimizing the inductive voltages are presented for the KSTAR PF coils. The quench hot spot analysis of the PF coils was carried out by the analytical and numerical methods for determining the proper values of the quench voltage threshold and the allowable quench protection delay time.

Analysis of Coupling Loss with Size and Material in the KSTAR PF Superconducting Coils (KSTAR PF 초전도자석의 크기 및 재료에 따른 결합손실 특성 분석)

  • Lee, H.J.;Chu, Y.;Lee, S.;Park, Y.M.;Park, H.T.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.1-5
    • /
    • 2009
  • It is important to predict AC loss in $Nb_3Sn$ and NbTi cable-in-conduit-conductor (CICC) reliably for the design and operation of large superconducting coils. The hysteresis loss in the superconducting filaments and coupling loss within strands and among strands in a cable or composite are dominant ac losses in superconducting magnets. The coupling loss in a superconductor can be characterized by identifying the coupling constant time $n{\tau}$. To reduce the coupling loss, all the strands (superconductor and Cu) in KSTAR (Korea Superconducting Tokamak Advance Research) are chromium plated with thickness of $l{\pm}0.5{\mu}m$. The ac losses of PF1, PF5 and PF6 coils has been measured by calorimetric method while applying trapezoidal current pulses with various ramp rate from 0.5 kA/s to 2 kA/s. The coupling time constants for $Nb_3Sn$ coils are $25{\sim}55$ ms and the values are not co-related with the coil size, the time constants for NbTi coil is 30 ms.

Regulatory Action of $\beta-adrenergic$ Agonist and 8-bromocyclic AMP on Calcium Currents in the Unfertilized Mouse Eggs

  • Haan, Jae-Hee;Cheong, Seung-Jin;Kim, Yang-Mi;Park, Choon-Ok;Hong, Seong-Geun
    • The Korean Journal of Physiology
    • /
    • v.27 no.2
    • /
    • pp.175-183
    • /
    • 1993
  • There are many report suggesting that influx and intracellular calcium concentration $([Ca^{2+}]_i)$ are related to cell signalling in various cells. However, it has not been reported that calcium channel activation is affected by the substances involved in signal transduction pathways in the mouse eggs. In this study, the effects of isoprenaline (ISP) and cyclic AMP on calcium influx through calcium channels were investigated to show their relationship with the signal transduction process in unfertilized mouse eggs. Using whole cell voltage clamp techniques, calcium currents, elicited by the depolarizing pulses of 300 ms duration (from -50 mV to 50 mV in 10 mV increments) from a holding potential of -80 mV, were recorded. The current-voltage (I-V) relation of calcium currents was shown to be bell-shaped; the current began to activate at -50 mV and reached its maximum $(-1.33{\pm}0.16\;nA:\;mean{\pm}S.E.,\;n=7)$ at -10 mV, then decayed at around 50 mV. Calcium currents were fully activated within $7\;ms{\sim}20\;ms$ and completely inactivated 200 ms after onset of the step pulse. ISP within the concentration ranges of $10^{-8}\;M{\sim}10^{-4}\;M$ dose-dependently increased the amplitude calcium current. The permeable cyclic AMP analogue,8-bromocyclic AMP, also increased its maximal amplitude by 46ft at $10^{-5}\;M$, while protein kinase inhibitor (PKI), which is known to inhibit 0.02 phosphorylating units of cyclic AMP-dependent protein kinase (PKA) per microgram decreased calcium currents. Currents recorded in the presence of PKI were resistant to increase by the application of $10^{-5}\;M$. Also, PKI inhibited the calcium current increase elicited by ISP treatment. These results suggest that $\beta-adrenergic$ regulation of the calcium channel is mediated by the cAMP-dependent protein kinase. This signal transduction pathway might play a role in regulating $[Ca^{2+}]_i$, level due to the increase of calcium influx in mouse eggs.

  • PDF

Study of the Efficiency Droop Phenomena in GaN based LEDs with Different Substrate

  • Yoo, Yang-Seok;Li, Song-Mei;Kim, Je-Hyung;Gong, Su-Hyun;Na, Jong-Ho;Cho, Yong-Hoon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.172-173
    • /
    • 2012
  • Currently GaN based LED is known to show high internal or external efficiency at low current range. However, this LED operation occurs at high current range and in this range, a significant performance degradation known as 'efficiency droop' occurs. Auger process, carrier leakage process, field effect due to lattice mismatch and thermal effects have been discussed as the causes of loss of efficiency, and these phenomena are major hindrance in LED performance. In order to investigate the main effects of efficiency loss and overcome such effects, it is essential to obtain relative proportion of measurements of internal quantum efficiency (IQE) and various radiative and nonradiative recombination processes. Also, it is very important to obtain radiative and non-radiative recombination times in LEDs. In this research, we measured the IQE of InGaN/GaN multiple quantum wells (MQWs) LEDs with PSS and Planar substrate using modified ABC equation, and investigated the physical mechanism behind by analyzing the emission energy, full-width half maximum (FWHM) of the emission spectra, and carrier recombination dynamic by time-resolved electroluminescence (TREL) measurement using pulse current generator. The LED layer structures were grown on a c-plane sapphire substrate and the active region consists of five 30 ${\AA}$ thick In0.15Ga0.85N QWs. The dimension of the fabricated LED chip was $800um{\times}300um$. Fig. 1. is shown external quantum efficiency (EQE) of both samples. Peak efficiency of LED with PSS is 92% and peak efficiency of LED with planar substrate is 82%. We also confirm that droop of PSS sample is slightly larger than planar substrate sample. Fig. 2 is shown that analysis of relation between IQE and decay time with increasing current using TREL method.

  • PDF

Multi-channel Transimpedance Amplifier Arrays in Short-Range LADAR Systems for Unmanned Vehicles (무인차량용 단거리 라이다 시스템을 위한 멀티채널 트랜스임피던스 증폭기 어레이)

  • Jang, Young Min;Kim, Seung Hoon;Cho, Sang Bock;Park, Sung Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.40-48
    • /
    • 2013
  • This paper presents multi-channel transimpedance amplifier(TIA) arrays in short-range LADAR systems for unmanned vehicles, by using a 0.18um CMOS technology. Two $4{\times}4$ channel TIA arrays including a voltage-mode INV-TIA and a current-mode CG-TIA are introduced. First, the INV-TIA consists of a inverter stage with a feedback resistor and a CML output buffer with virtual ground so as to achieve low noise, low power, easy current control for gain and impedance. Second, the CG-TIA utilizes a bias from on-chip bandgap reference and exploits a source-follower for high-frequency peaking, yielding 1.26 times smaller chip area per channel than INV-TIA. Post-layout simulations demonstrate that the INV-TIA achieves 57.5-dB${\Omega}$ transimpedance gain, 340-MHz bandwidth, 3.7-pA/sqrt(Hz) average noise current spectral density, and 2.84mW power dissipation, whereas the CG-TIA obtains 54.5-dB${\Omega}$ transimpedance gain, 360-MHz bandwidth, 9.17-pA/sqrt(Hz) average noise current spectral density, and 4.24mW power dissipation. Yet, the pulse simulations reveal that the CG-TIA array shows better output pulses in the range of 200-500-Mb/s operations.

Special quality research about action output waveform change by gap (1.0mm and 1.6mm)difference of skin excessive expense $CO_2$ Laser (피부과용$CO_2$ 레이저의 공극(1.0mm및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성 연구)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.2
    • /
    • pp.107-112
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Measurement of Vestibular Ocular Reflex in Normal Subjects Using Galvanic Stimulator and Videooculograph (전기자극과 VOG(Videooculograph)를 이용한 정상인의 전정 안반사 측정)

  • 김수찬;정운교;남기창;이원상;김영하;김덕원
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.487-496
    • /
    • 2001
  • In this study, a galvanic stimulator providing bipolar mode controlled by a PIC(peripheral interface controller) was constructed to evaluate vestibular function The maximum load and maximum current intensity of the constant current source were 3$k\Omega$ and 5mA. respectively. and it could Produce DC, sine wavers. or Pulse waves. Eve movements of 20 normal subjects by galvanic stimulation were analyzed using a commercial videooculogragh. During stimulating with DC for 30 sec. we recorded the response of eye movement with current intensity of 0.75. 1 2, and 3 mA. Nystagmus occurred to all the subjects when the galvanic stimulus intensity was larger than 2 mA. Average SPV(slow Phase eye movement velocity) and the number of nystagmus increased from 7.1 to 4.8 deg/sec and from 17 to 48, respectively, when the stimulus current increased from 0.75 to 3 mA. All the fast eye movement of the nystagmus were the direction of the negative electrode. The asymmetry which means the difference between right- and left-eye movements decreased when the stimulus intensity increased. It is expected that this study would be useful in evaluating vestibular function and in studying basic Physiology mechanism of vestibular ocular reflex by galvanic stimulus .

  • PDF

Nitric Oxide (NO) Inhibites the Neuronal Activities in the Rat Nucleus Tractus Solitarius

  • Kim, Mi-Won;Park, Mun-Sung;Ryu, Sun-Youl;Jung, Ji-Yeon;Kim, Sun-Hun;Kim, Min-Seok;Kim, Won-Jae;Jeong, Yeon Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.8 no.1
    • /
    • pp.7-15
    • /
    • 2004
  • Nitric oxide (NO) system has been implicated in a wide range of physiological functions in the nervous system. However, the role of NO in regulating the neural activity in the gustatory zone of nucleus tractus solitarius (NTS) has not been established. The present study was aimed to investigate the role of NO in the gustatory NTS neurons. Sprague-Dawley rats, weighing about 50 g, were used. Whole cell patch recording and immunohistochemistry were done to determine the electrophysiological characteristics of the rostral gustatory nucleus of the tractus solitaries and distribution of NO synthases (NOS). Neuronal NOS (nNOS) immunoreactivity was strongly detected along the solitary tract extending from rostral to caudal medulla. Resting membrane potentials of NTS neurons were $-49.2{\pm}2\;mV$ and action potential amplitudes were $68.5{\pm}2\;mV$ with a mean duration measured at half amplitude of $1.7{\pm}0.3\;ms$. Input resistance, determined from the response to a 150 ms, -100 pA hyperpolarizing current pulse, was $385{\pm}15\;M{\Omega}$, Superfusion of SNAP or SNP, NO donors, produced either hyperpolarization (68%), depolarization (5%), or no effect (27%). The hyperpolarization was mostly accompanied by a decrease in input resistance. The hyperpolarization caused by SNAP or SNP increased the time to initiate the first action potential, and decreased the number of action potentials elicited by current injection. SNP or SNAP also markedly decreased the number of firing neural discharges of the spontaneous NTS neural activity under zero current. Superfusion of L-NAME, a NOS inhibitor, slightly depolarized the membrane potential and increased the firing rate of NTS neurons induced by current injection. ODQ, a soluble guanylate cyclase inhibitor, ameliorated the SNAP-induced changes in membrane potential, input resistance and firing rates. 8-Br-cGMP, a non-degradable cell-permeable cGMP, hyperpolarized the membrane potential and decreased the number of action potentials. It is suggested that NO in the gustatory NTS has an inhibitory role on the neural activity of NTS through activating soluble guanylate cyclase.

The Effect of Hand Massage on Pain and Anxiety Related to Chest Tube Removal in Patients with a Lobectomy (손마사지가 폐엽 절제술 환자의 흉관 제거시 통증과 불안에 미치는 영향)

  • Song Yeoung-Suk
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.9 no.1
    • /
    • pp.27-44
    • /
    • 2002
  • The main purpose of this study was to identify the effect of hand massage on pain and anxiety related to chest tube removal in patients with a lobectomy. The research design of this study was a nonequivalent control group non-synchronized design. Of the twenty nine adult subjects, fourteen were assigned to the experimental group and fifteen to the control group. The data were obtained over 3 months from a medical center in Seoul. The instruments used to assess trait state anxiety was the Spielberger Trait-State anxiety Inventory. For pain and psychological anxiety. The Visual Analogue Scale was used. Hiko analogue sphygmo-manometer(2001) was used to check blood pressure and pulse rate as indicators of physiological anxiety Subjects in the experimental group received hand massage for 5 minutes just before chest tube was removed, and subjects assigned to the control group did not receive hand massage. Data were analysed with $x^2$-test and Mann-Whitney U test using the SPSSWIN 10.0 program. The results of the study are as follows : 1. Hypothesis 1: 'there will be a significant difference between two groups in the level of pain after chest tube removal' was supported (u = 23.00, p < 0.001). 2. Hypothesis 2: 'there will be a significant difference between the two groups in the level of psychological anxiety after chest tube removal' was supported (u = 3.00, p < 0.001). 3. Hypothesis 3: 'there will be a significant difference between the two groups in physiological anxiety(systolic, diastolic blood pressure and pulse rate) after chest tube removal' was supported(u =55.50, p = 0.01 ; u = 41.50, p = 0.01 ; u = 20.50, p < 0.001, relatively). The findings of this study indicate that hand massage is effective for pain and anxiety related to chest tube removal in patients with lobectomy. Therefore, hand massage is recommended as an effective nursing intervention for relieving pain and anxiety in patients undergoing chest tube removal. Further research is needed to identify the proper duration and timing to achieve the optimal effect of hand massage. A larger subject population is required to apply the current findings to the general population. Further research is also needed to assess the effects of hand massage in other patient subsets. Finally, it would be interesting to see if the effects of hand massaging would be attenuated when performed by a non-medical specialist.

  • PDF