• 제목/요약/키워드: current pulse

Search Result 1,869, Processing Time 0.029 seconds

The phase transition with electric field in chalcogenide thin films (칼코게나이드 박막의 전기적 펄스에 의한 상변화 연구)

  • Yang, Sung-Jun;Shin, Kyoung;Lee, Jae-Min;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.115-118
    • /
    • 2004
  • The phase transition between amorphous and crystalline states in chalcogenide semiconductor films can controlled by electric pulses or pulsed laser beam; hence some chalcogenide semoconductor films can be applied to electrically write/erase nonvolatile memory devices, where the low conductive amorphous state and the high conductive crystalline stale are assigned to binary states. AST(AsSbTe) used to phase change material by applying electical pulses. Thickness of AST chalcogenide thin film have about 100nm. Electrodes are made of ITO and Al. $T_c$(Crystallization temperature) of AST system is lower than that of the GST(GeSbTe) system, so that the current pulse width of crystallization process can be decreased.

  • PDF

Improvement of Ozone Yield by a Multi-Discharge Type Ozonizer Using Super position of Silent Discharge Plasma (무성방전의 중첩을 이용한 다중방전형 오존발생기의 오존생성수율 개선)

  • Song, Hyun-Jig;Lee, Dong-Heon;Oh, Jin-Hoon;Park, Seong-Wook;Seo, Young-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.88-91
    • /
    • 2004
  • In order to improve ozone generation, we experimentally investigated the silent discharge plasma and ozone generation characteristics of a multi-discharge type ozonizer. Ozone in a multi-discharge type ozonizer is generated by superposition of a silent discharge plasma, which is simultaneously generated in separated discharge spaces. A multi-discharge type ozonizer is composed of three different kinds of superposed silent discharge type ozonizers, depending on the method of applying power to each electrode. We observed that the discharge period of the current pulse for a multi-discharge type ozonizer can be longer than that of silent discharge type ozonizer with two electrodes and one gap.Hence, ozone generation is improved up to 17185 ppm and 783 g/kwh for the superposed silent discharge type ozonizer for which an AC high voltages with a 180 phase difference were applied to the internal electrode and the external electrode, respectively, with the central electrode being ground

  • PDF

An Evaluation of Voltage Source PAWM Inverter by Torque Ripple Content (토오크 맥동량에 의한 전압원 PAWM 인버터의 평가)

  • Lee, Chi-Hwan;Koo, Bon-Ho;Kwon, Wo-Hyen
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.5
    • /
    • pp.60-70
    • /
    • 1989
  • In this paper, a new HTF(Harmonic torque function) which takes into account the phasor of harmonic current, and which represents torque ripple content of induction motor is proposed. Through experiments and computer simulations using direct-quadrature two axis model, the proposed HTF is proved to be valid. Applying this function, six-step, SPWM and TPWM pulse-amplitude-width-controlled inverters are evaluated and compared with each other. A good control strategy for PAWM inverters was chosen from the results. It turns out that TPWM is superior to SPWM in torqur ripple content and output voltage amplitude of fundamental wave and six-step is better than PWM when CR is 9.

  • PDF

Highly Robust AHHVSCR-Based ESD Protection Circuit

  • Song, Bo Bae;Koo, Yong Seo
    • ETRI Journal
    • /
    • v.38 no.2
    • /
    • pp.272-279
    • /
    • 2016
  • In this paper, a new structure for an advanced high holding voltage silicon controlled rectifier (AHHVSCR) is proposed. The proposed new structure specifically for an AHHVSCR-based electrostatic discharge (ESD) protection circuit can protect integrated circuits from ESD stress. The new structure involves the insertion of a PMOS into an AHHVSCR so as to prevent a state of latch-up from occurring due to a low holding voltage. We use a TACD simulation to conduct a comparative analysis of three types of circuit - (i) an AHHVSCR-based ESD protection circuit having the proposed new structure (that is, a PMOS inserted into the AHHVSCR), (ii) a standard AHHVSCR-based ESD protection circuit, and (iii) a standard HHVSCR-based ESD protection circuit. A circuit having the proposed new structure is fabricated using $0.18{\mu}m$ Bipolar-CMOS-DMOS technology. The fabricated circuit is also evaluated using Transmission-Line Pulse measurements to confirm its electrical characteristics, and human-body model and machine model tests are used to confirm its robustness. The fabricated circuit has a holding voltage of 18.78 V and a second breakdown current of more than 8 A.

원격측정명령처리기 릴레이구동 회로 설계 및 구현

  • Kim, Joong-Pyo;Koo, Ja-Chun
    • Aerospace Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.170-176
    • /
    • 2004
  • In this study, the relay driver circuit which controls the spacecraft configuration change are implemented and validated. First of all, the specification of the relay driver circuit is defined, and then its circuit meeting the specification defined is designed. In order to verify the design of the relay driver circuit, its circuit was simulated, and then it's confirmed that the relay pulse current and voltage level defined in the specification are obtained, and the results obtained through the functional test of the relay driver circuit are compared and well matched with the simulation results. Also the worst case analysis for confirming the stable operation of the relay driver circuit under the tolerance of each component is performed.

  • PDF

Idle Slots Skipped Mechanism based Tag Identification Algorithm with Enhanced Collision Detection

  • Su, Jian;Xu, Ruoyu;Yu, ShiMing;Wang, BaoWei;Wang, Jiuru
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.5
    • /
    • pp.2294-2309
    • /
    • 2020
  • In this article, a new Aloha-based tag identification protocol is presented to improve the reading efficiency of the EPC C1 Gen2-based UHF RFID system. Collision detection (CD) plays a vital role in tag identification process which determines the efficiency of anti-collision protocols since most Aloha-based protocols optimize the incoming frame length based on the collisions in current frame. Existing CD methods are ineffective in identifying collision, resulting in a degradation of identification performance. Our proposed algorithm adopts an enhanced CD (ECD) scheme based on the EPC C1 Gen2 standard to optimize identification performance. The ECD method can realize timely and effective CD by detecting the pulse width of the randomly sent by tags. According to the ECD, the reader detects the slot distribution and predicts tag cardinality in every collision slot. The tags involved in each collision slot are identified by independently assigned sub-frames. A large number of numerical results show that the proposed solution is superior to other existing anti-collision protocols in various performance evaluation metrics.

Comparison on Spray Characteristics of Diesel HEV Injectors for 3-different Driving Type (SI, PI, DPI) (3개 구동방식(SI, PI, DPI)별 디젤HEV용 인젝터의 분무 특성 비교)

  • Chung, M.C.;Sung, G.S.;Kim, S.M.;Lee, J.W.
    • Journal of ILASS-Korea
    • /
    • v.19 no.1
    • /
    • pp.9-14
    • /
    • 2014
  • Performance of DI diesel engine with high-pressure fuel injection equipment is directly related to its emission characteristics and fuel consumption. So, the electro-hydraulic injector for the common-rail injection system should be designed to meet the precise high fuel delivery control capability. Currently, most high pressure injector in use has a needle driven by the solenoid coil energy or the piezo actuator controlled by charge-discharge of output pulse current. In this study, macroscopic spray approaching method was applied under constant volume chamber to research the performance of three different injectors : solenoid, indirect-acting piezo and direct-acting piezo type for CR direct-injection. LED back illumination for Mie scattering was applied on the liquid spray visible of direct-acting piezo injector, including hydraulic-servo type solenoid and piezo-driven injectors. As main results, we found that a direct-acting piezo injector had better a spray tip penetration than hydraulic-servo injectors in spray visualization.

Microstructure and Electric Properties of Ferroelectric SrBi$_2$Ta$_2$O$_9$ Thin Films Deposited by Modified Rf Magnetron Sputtering Technique (Modified Rf Magnetron Sputtering에 의해 Pt/Ti/SiO$_2$/Si 기판위에 제조된 강유전체 SrBi$_2$Ta$_2$O$_9$ 박막의 미세구조 및 전기적 특성 연구)

  • 양철훈;윤순길
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.5
    • /
    • pp.472-478
    • /
    • 1998
  • Ferroelectric SrBi2Ta2O9(SBT) films were deposited on Pt/Ti/SiO2/Si substrates at 50$0^{\circ}C$ using a sintered SBT target Bi and Ta targets by modified rf magnetron sputtering and then were annealed at 80$0^{\circ}C$ for 10min in oxygen ambinet(760 torr) The composition of the SBT films could be easily controlled using the mul-ti-targets. The film composition of {{{{ {Sr }_{0.8 } {Bi }_{2.9 } {Ta}_{2.0 } {O }_{9 } }} was obtained with SBTd sputtering power of 100 W Bi of 25W and Ta of 10 W. A 250nm thick SBT films exhibited a dense and uniform microstructure and showed the remanent polarization(Pr) of 14.4 $\mu$C/cm2 and the coercive field({{{{ {E }_{c } }})of 60 kV/cm at applied voltage of 5 V. The SBT films show practically no polarization fatigue up to {{{{ {10 }_{10 } }} cycles under 5V bipolar pulse. The retention characteristics of the SBT films looked very promising and the leakage current density of the SBT films was about 1.23$\times${{{{ {10 }^{-7 } }}A/c{{{{ {m }^{2 } }} at 120kV/cm.

  • PDF

Study on quench detection of the KSTAR CS coil with CDA+MIK compensation of inductive voltages

  • An, Seok Chan;Kim, Jinsub;Ko, Tae Kuk;Chu, Yong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.55-58
    • /
    • 2016
  • Quench Detection System (QDS) is essential to guarantee the stable operation of the Korea Superconducting Tokamak Advanced Research (KSTAR) Poloidal Field (PF) magnet system because the stored energy in the magnet system is very large. For the fast response, voltage-based QDS has been used. Co-wound voltage sensors and balanced bridge circuits were applied to eliminate the inductive voltages generated during the plasma operation. However, as the inductive voltages are hundreds times higher than the quench detection voltage during the pulse-current operation, Central Difference Averaging (CDA) and MIK, where I and K stand for mutual coupling indexes of different circuits, which is an active cancellation of mutually generated voltages have been suggested and studied. In this paper, the CDA and MIK technique were applied to the KSTAR magnet for PF magnet quench detection. The calculated inductive voltages from the MIK and measured voltages from the CDA circuits were compared to eliminate the inductive voltages at result signals.

Wavelet Analysis of Partial Discharges in Needle-Plane Air Gap (침-평판 전극 구조에서 기중 부분방전의 Wavelet 해석)

  • Kang, S.H.;Park, Y.G.;Lee, D.J.;Shin, D.W.;Lim, K.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1523-1525
    • /
    • 1996
  • Partial discharges(PD) in air insulated electric power systems cause power loss, produce interfering electromagnetic radiation, and can indicate incipient failure. An understanding of PD in air gap is clearly important. The Wavelet transformation is an extended method of fourier transformation. The fourier method is a powerful tool for signal analysis, but it can't include informations for time. However tile wavelet transformation analysis can include on the informations of time and frequency at the same time. In this paper we apply the wavelet transformation to the PD signals in needle-plane air gap for tile purpose of analysis of developing aspects of PD. We can analyze the developing aspects of PD, namely, PD current, repetition rates, width of pulse distribution region, pulseless region and frequencies distribution of PD pulses.

  • PDF