• Title/Summary/Keyword: current phase

Search Result 5,370, Processing Time 0.052 seconds

Comparison of the harmonic reduction by using harmonic passive fitters and technique of intervene firing method at the pulse of the 6-pulse phase controlled converter.

  • Wongtongdee, Surached W.;Laohasongkram, Pipat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.782-785
    • /
    • 2005
  • This article introduces technique to reduce harmonic by using the $5^{th}$ and $7^{th}$ harmonic tune filter and line reactor in the comparison to the technique of intervening firing method at the pulse of the 6-pulse phase-controlled converter in every 1/6 period. The design of the technique introduced in this article is to reduce the harmonic distortion of the current and the voltage resulted from three-phase thyristor phase-controlled converter. The waveform obtained from the experiment was analyzed on the spectrum of the current, voltage and the total harmonic distortion. The double firing method causes zero vectors of output voltage and input current. Designing the mechanism of the converter based on the idea of Park Vector Theory, the number of harmonic distortion in the intervening firing method were compared to those in normal firing method.

  • PDF

A PFC Controller Design for 3-Phase Modular UPS (3상 모듈형 UPS용 PFC 제어기 설계)

  • Kim, Sang-Hoon;Park, Nae-Chun
    • Journal of Industrial Technology
    • /
    • v.31 no.B
    • /
    • pp.75-79
    • /
    • 2011
  • In this paper a new PFC Controller for 3-Phase Modular UPS(Uninterruptible Power Supplies) is proposed. The PFC circuit for 3-Phase Modular UPS is implemented using three 1-phase 3-level boost PFC circuits. To control DC output voltage, single voltage controller considering imbalance of two capacitor voltages and to regulate AC input current three independent current controllers are used in proposed PFC controller. By the proposed method, without additional hardware, THD(Total Harmonic Distortion) of input currents can be readily limited below 5% which is the harmonic current requirements by IEEE std. 519. Its validity is verified by simulations and experiments.

  • PDF

Analysis of Relationship between Standard Depth of Penetration Skin Effect and Phase Angle of Defect Signal of Eddy Current Testing (와전류(渦電流) 표준침투(標準浸透) 깊이 표피효과(表皮效果)와 결함신호(缺陷信號) 위상각(位相角)의 관계해석(關係解析))

  • Chung, Tae-Eon;Chang, Kee-Oak;Park, Dae-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.4 no.2
    • /
    • pp.7-14
    • /
    • 1985
  • An experiment to investigate the rate of change of phase angle of eddy current output signal caused by outer surface defect of nonferromagnetic tube by variation of standard depth of penetration and variation of percent of tube wall penetration was carried out. The results of the experiment show that the phase angle of defect signal is increased with decreasing the standard depth of penetration or the depth of defect. The results also show that the phase angle is decreased with increasing the skin effect of eddy current, and that the resolution is decreased with decreasing the depth of defect.

  • PDF

3-Phase Hybrid Series Active Power Filter with Dynamic Voltage Restorer (DVR 기능을 갖는 3상 하이브리드형 직렬 능동전력필터)

  • Han Seok-Woo;Choe Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.598-602
    • /
    • 2002
  • This paper presents the 3-phase hybrid series active power filter with dynamic voltage restorer(DVR) which serve as an energy buffer and current harmonics blocking resistor connected to sensitive loads, such as, to compensate voltage dips and current harmonics in power distribution system. The DVR is to inject a dynamically controlled voltage generated by a forced commutated converter in series to the bus voltage by means of a booster transformer. The momentary amplitudes of the three injected phase voltages are controlled such as to eliminate any detrimental effects of a bus fault to the load voltage. The proposed system is able to simultaneously compensate current harmonics, voltage fluctuating and voltage unbalance in power distribution systems. The reference phase angle detected by synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The effectiveness of proposed system is verified by the computer simulation.

  • PDF

The Comparison Study for Voltage, Current and Load Unbalance Factor (전압, 전류 및 부하 불평형율에 대한 비교 연구)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.2
    • /
    • pp.88-93
    • /
    • 2005
  • Most of the LV customer have been applied the distribution system of 3-phase four wire system because of its advantage of supplying both of 1-phase & 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But uneven load distribution or unclean voltage quality has occurred various problems such as de-rating, losses increase and vibration, etc. In this paper, voltage, current and power waveform in the actual fields have measured and analyzed in relation with internationally allowable voltage unbalance limits and compared the current unbalance factor with the load unbalance factor.

Numerical Analysis on the Electromagnetic Phenomena in High Power Isolated Phase (대전력용 상분리 모선의 전자계 현상 수치해석)

  • Kim, Jin-Soo;Ha, Duk-Yong;Choi, Seung-Kil;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1990-1992
    • /
    • 2000
  • Isolated phase bus is, as a special bus which allows large current from a generator to main transformer, composed of main conductor, enclosure and auxiliary equipments such as insulating bellows, bus elbows, support insulator, etc. To develop this kind of high power devices, it is required to secure the technique of selection of conducting and insulating materials, basic arrangement skills, and analysis on eddy current which causes temperature increase in enclosures. By the way, these techniques are based on the analysis of electromagnetic phenomena for high voltage and large current. In this study, an electromagnetic field analysis program is developed and applied to the isolated phase bus. which could be the basic numerical method for the analysis design and modifying isolated phase bus.

  • PDF

Current Control of Three Phase PWM Converter for the Variable Load (부하가변시 3상 PWM 컨버터의 전류제어에 관한 연구)

  • Lee, J.H.;Kim, E.G.;Jeon, K.Y.;Chun, J.Y.;Lee, S.H.;Oh, B.H.;Lee, H.G.;Han, K.H.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.441-443
    • /
    • 2007
  • In this paper, The authors design the current controller which independently control the d, q axis current transformed by the synchronously rotating d, q axis and a Space Vector Pulse Width Modulation(SVPWM) to steadily control the output DC-Link voltage against the variable load of the three phase PWM converter. Also, This study improves the high power factor, stability, and rapid response by the phase angle control using the digital Phase Locked Loop(PLL).

  • PDF

Low-Cost Single-Phase to Three-Phase PWM Converters for Induction Motor Drives (유도전동기 구동을 위한 저가형 단상-3상 AC/DC/AC PWM 컨버터)

  • Kim Tae-Yun;Lee Dong-Choon;Seok Jul-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.201-204
    • /
    • 2001
  • In this paper, a single-phase to three-phase PWM converter topology using six switches only for low cost induction motor drive is proposed. The converter topology is of lower cost than the conventional one, which gives sinusoidal input current, unity power factor, dc output voltage control and bidirectional power flow In addition, the source voltage sensor is eliminated by controlling the deviation between the model current and the system current to be zero. The performance of the proposed converter has been demonstrated through the computer simulation.

  • PDF

Novel SRM Drive Systems Using Variable DC-Link Voltage

  • Jang, Do-Hyun
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.285-293
    • /
    • 2011
  • This paper proposes two SRM driving systems using a variable dc-link voltage controlled by a single-phase inverter. Two SRM converter topologies of a half bridge type and a full bridge type are proposed according to the power circuits of an inverter. The phase current can be controlled by means of a PWM controller at the inverter, and the turn-on/off angle at the phase switches can be controlled by a position sensor at the converter in the drive system. The inverter acts as a peak-current limiter if the transient current exceeds its maximum value. SRMs using the proposed topologies maintain high efficiency due to energy regeneration after the turn-off of power switches. The operational modes of the proposed topologies are verified by simulation and experimental results.

Rotational and fractional effect on Rayleigh waves in an orthotropic magneto-thermoelastic media with hall current

  • Lata, Parveen;Himanshi, Himanshi
    • Steel and Composite Structures
    • /
    • v.42 no.6
    • /
    • pp.723-732
    • /
    • 2022
  • The present research is concerned to study the effect of fractional parameter and rotation on the propagation of Rayleigh waves in an orthotropic magneto-thermoelastic media with three-phase-lags in the context of fractional order theory of generalized thermoelasticity with combined effect of rotation and hall current. The secular equations of Rayleigh waves are derived by using the appropriate boundary conditions. The wave properties such as phase velocity, attenuation coefficient are computed numerically and the numerical simulated results are presented through graphs to show the effect on all the components. Some special cases are also discussed in the present investigation.