• Title/Summary/Keyword: current phase

Search Result 5,370, Processing Time 0.042 seconds

Analysis of the Phase Current Measurement Boundary of Three Shunt Sensing PWM Inverters and an Expansion Method

  • Cho, Byung-Geuk;Ha, Jung-Ik;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.232-242
    • /
    • 2013
  • To obtain phase currents information in AC drives, shunt sensing technology is known to show great performance in cost-effectiveness and therefore it is widely used in low cost applications. However, shunt sensing methods are unable to acquire phase currents in certain operation conditions. This paper deals with the derivation of the boundary conditions for phase current reconstruction in three-shunt sensing inverters and proposes a voltage injection method to expand the measurable areas. As the boundary conditions are deeply dependent on the switching patterns, they are typically analyzed on the voltage vector plane for space vector pulse width modulation (SVPWM) and discontinuous pulse width modulation (DPWM). In the proposed method, the voltage injection and its compensation are conducted within one sampling period. This guarantees fast current reconstruction and the injected voltage is decided so as to minimize the current ripple. In addition to the voltage injection method, a sampling point shifting method is also introduced to improve the boundary conditions. Simulation and experimental results are presented to verify the boundary condition derivation and the effectiveness of the proposed voltage injection method.

Three-Phase Three-Switch Buck-Type Rectifier Based on Current Source Converter for 5MW PMSG Wind Turbine Systems

  • Chae, Beomseok;Suh, Yongsug;Kang, Tahyun
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1501-1512
    • /
    • 2018
  • This paper proposes a three-phase three-switch buck-type converter as the MSC of a wind turbine system. Owing to a novel switching modulation scheme that can eliminate the unwanted diode rectifier mode switching state, the proposed system exhibits a satisfying ac voltage and current waveform quality and torque ripple up to the level of a typical current source rectifier even under a wide power factor operating range. The proposed system has been verified through simulations and HILS tests on a PMSG wind turbine model of 5MW/4160V. The proposed converter has been shown to provide a stator current THD of 3.9% and a torque ripple of 1% under the rated power condition. In addition to the inherent advantage of the reduced switch count of three-phase three-switch buck-type converters, the proposed switching modulation technique can make this converter a viable solution for the MSC placed inside of a nacelle, which is under severe volume, weight and mechanical vibration design limits.

Study on the Variation of Reactive Power When Applying the Passive Filter (수동형 필터 적용시 무효전력의 변화에 관한 연구)

  • Kim, Ji-Myeong;Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1626-1631
    • /
    • 2016
  • Generally, the low-voltage customer has been used with a linear load and nonlinear load in the 3-phase 4-wire distribution system. Linear load has usually configured the resistance and inductance, current phase is slower than the voltage phase, so power factor is low. It is required for the power factor correction device prior to the phase of the current than the voltage. The capacitor is connected in parallel to the load in order to ensure a low power factor. Power converter such as an inverter is a typical non-linear load. Non-linear load generates harmonic currents in the energy conversion process. Many electrical equipment may be adversely affected by the harmonic current. There, passive or active filter have been used to reduce these harmonics current. Passive filter consisting of inductor and capacitor generates a reactive power. According to the combination of filter inductor and capacitor, reactive power can be adjusted. In this paper, we analyzed how the combination of inductor and capacitor affects the overall power factor by simulation and measurement.

Study on the Distribution of Electromagnetic Force for 154 kV Power Transmission Cable on Dual Underground Lines by Normal and Earth Fault Current (지중 2회선 154 kV 송전케이블의 정상 및 지락고장에 따른 전자기력 분포에 관한 연구)

  • Kim, Hui Min;Kim, So Young;Im, Sang Hyeon;Park, Gwan Soo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • The goal of this study is the size and distribution of the electromagnetic force generated by the current flowing through the second underground line of 154kV power transmission cables by using electromagnetic finite element analysis. So we interpret how mutually electromagnetic force has an effect on the comparable judgement of Trefoil, Duct and Flat, which shows in a numerical arrangement. 154kV OF 1200SQ Cable 1.281km not only is applicable to modeling for underground transmission cable but also examine the effect of line to line, phase to phase and size and direction of the electromagnetic force preparing for the occurrence of normal state and single-phase earth fault, which are arranged in trefoil, duct and flat formation between sections. As showing how the trajectory, and size distribution of the electromagnetic force translate as the arrangement of the cables when a steady-state current and a fault current flows on the underground cables, I hope that when Underground transmission is designed, this data will be useful information.

A New On-Line Dead-Time Compensator for Single-Phase PV Inverter (단상 PV 인버터용 온라인 데드타임 보상기 연구)

  • Vu, Trung-Kien;Lee, Sang-Hoey;Cha, Han-Ju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.409-415
    • /
    • 2012
  • This paper presents a new software-based on-line dead-time compensation technique for a single-phase grid-connected photovoltaic (PV) inverter system. To prevent a short circuit in the inverter arms, a switching delay time must be inserted in the pulse width modulation (PWM) signals. This causes the dead-time effect, which degrades the system performance around zero-crossing point of the output current. To reduce the dead-time effect around the zero-crossing point of grid current, a harmonic mitigation of grid current is used as an additional part of the synchronous frame current control scheme. This additional task mitigates the harmonic components caused by the dead-time from the grid current. Simulation and experimental results are shown to verify the effectiveness of the proposed dead-time compensation method in the single-phase grid-connected inverter system.

Three Phase Drive Transfer Algorithm for Fault Tolerance Control of Six-Phase PMSM (6상 영구자석 동기전동기의 고장대응운전을 위한 3상 구동시스템 전환 알고리즘)

  • Kim, Seong-Hoon;Jang, Won-Jin;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.256-262
    • /
    • 2021
  • Six-phase motors can be used in industrial applications, such as an electric vehicle, due to their high reliability and low current magnitude per phase. An asymmetrical PMSM with two sets of three-phase windings is a commonly used structure for six-phase motors, with each winding set demonstrating a phase difference of 30°. Although the asymmetrical PMSM presents low torque ripples, its dynamic torque response deteriorates due to coupled components in the two three-phase windings. The decoupled VSD control is applied to eliminate the coupling effect. Load ratio control of two inverters for the six-phase PMSM is proposed in this study. DQ currents are controlled on the basis of two synchronous reference frames, and the six-phase drive system can be changed to a three-phase drive system when one inverter presents fault conditions. The operation and effectiveness of the proposed algorithm is verified through simulation and experiments. The six-phase drive system is transferred to a three-phase drive system by changing the current reference of the second DQ reference frame. Moreover, control of both torque and speed exhibits satisfactory performance before and after the mode change.

The Properties of Na-Ca Exchange Current in Single Atrial Cells of ,The Rabbit (토끼 단일 심방근 세포에서 Na-Ca 교환전류의 특성에 관한 연구)

  • Youm, Wook;Ho, Won-Kyung;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.548-561
    • /
    • 1989
  • In single atrial cells isolated from the rabbit the properties of inward current of Na-Ca exchange were investigated using the whole cell voltage clamp technique. The current was recorded during repolarization following brief 2 ms depolarizing pulse to +40 mV from a holding potential of * 70 mV. Followings are the results obtained: 1. When stimulated every 30 seconds, the inward currents were activated and reached peak values 6-12 ms after the beginning of depolarizing pulse. The mean current amplitude was 342 pA/cell. 2. The current decayed spontaneously from the peak activation and the time course of the relaxation showed two different phases fast and slow phase. The time constants were 10-18 ms and 60-140 ms, respectively. 3. The recovery of inward current was tested by paired pulse of various intervals. The peak current recovered exponentially with time constant of 140 ms and 1 p M isoprenaline accelerated the recovery process. 4. Relaxation time course was also affected by pulse interval and time constant of the fast phase was reduced almost linearly according to the decrease of pulse interval between 30 sec and 1 sec. 5. The peak activation was increased in magnitude by long prepulse stimulation, 5 p M Bay K, 1 p M isoprenaline or internal and external application of c-AMP. 6. The relaxation time constant of the fast phase was prolonged by 5 p M Bay K or c-AMP, and shortened by isoprenaline. However the time course of the slow relaxation phase was not so much changed. From the above results, it could be concluded that increase of the calcium current by Bay K or c-AMP results in the potentiation and prolongation of intracellular calcium transient, and the facilitation of Ca uptake by SR might be a mechanism of shortening the time constant of current relaxation by short interval stimulation or isoprenaline.

  • PDF

A Study on the AC Pow a Study on the AC Power Control Circuit by Combining PWM and Phase Control (PWM과 입상제어의 조합에 의한 교류전력 제어회로에 관한 연구)

  • 정화균;김이곤;장영학
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.2
    • /
    • pp.84-95
    • /
    • 1991
  • Mostly, phase control method is used to control the single phase AC power. The phase control method has some advantages such as ease to control and simple configuration. But the retardation of firing angle causes a lagging current even if load is purely resistive. So phase control causes a lagging power factor and a low efficiency at the input side in comparing with the system without switching device. A new PWM control method which can improve these defects for single phase AC power control circuit is proposed in this paper. The performances of the single phase AC power control circuit using the proposed method was investigated theoretically. Both power factor and waveform of load current can be improved better than those of the conventional methods.

  • PDF

Evaluation technique for phase displacement of current transformer comparator (전류변성기 비교기의 위상오차 평가 기술)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2032-2033
    • /
    • 2008
  • We have developed an evaluation technique for phase displacement of current transformer (CT) comparator by using the precise standard capacitors and resistors. By applying this technique for equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured phase displacement in the CT comparator. Thus we can evaluate phase displacement of CT comparator by comparing the calculated and measured phase displacement. The method was applied to CT comparator under test with the phase displacement ranges of $0{\sim}{\pm}7.5$ crad. Finally we have compared the phase displacement of the CT comparator under test theoretically obtained in this method with the specification.

  • PDF

Characteristics of Non-Isolated OSAKA Converter -Characteristics of Three-Phase Soft-Switching Power Factor Corrected Converter for Large Scale Power Without Three-Phase Transformer-

  • Taniguchi, Katsunori;Shimomori, Wataru;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1383-1386
    • /
    • 2005
  • Non-isolated OSAKA Converter, which removes a three-phase transformer, is described in this paper. The converter switches once in every half cycle of an AC commercial power source. Therefore, it can solve many problems caused by the high frequency operation. The proposed converter achieves the soft-switching operation and the EMI noise can be reduced. In this circuit, the resonant capacitor, which is used for the soft-switching operation, is utilized for the improvement of an input current waveform. To achieve low cost and compact structure, non-isolated OSAKA converter removes a three-phase transformer of the OSAKA converter. By removing the three-phase transformer, three phase currents occur the interferences each other. To avoid the interference, a new switching method for non-isolated OSAKA converter is preposed. The converter can be constructed by the low-speed large power devices. The converter generates the low distorted input current waveforms with high power factor.

  • PDF