• 제목/요약/키워드: current phase

Search Result 5,398, Processing Time 0.039 seconds

Control of Three-Phase PWM Rectifiers Using Only DC-Side Sensors (직류측 센서만을 이용한 3상 PWM 정류기의 제어)

  • 이동춘
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.278-281
    • /
    • 2000
  • In this abstract a novel control scheme of voltage-source PWM rectifiers using only dc-side sensors is proposed. The phase currents are reconstructed from switching states of the rectifier and the dc output current. For effective current control the currents are estimated by a predictive state observer. Also both the phase angle and the magnitude of th source voltage are estimated by phase estimator and magnitude estimator respectively. The validity of the proposed ac sensorless technique is verified by experimental results.

  • PDF

Comparison of SRM rotor position estimation algorithm using flux-current methods (자속 모델 기준 추종방식을 이용한 SRM 회전자 위치평가알고리즘 비교)

  • 안재황
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.697-700
    • /
    • 2000
  • This paper introduces a new rotor position estimation algorithm for the SRM based on the magnetizing curves of aligned and unaligned rotor positions. The flux linkage is calculated by the measured data from phase voltage and phase current and the calculated data are used as the input of magnetizing profiles for rotor position detection. Each of the magnetizing profiles consisted of the methods using the neural network and fuzzy algorithm And also the optima phase is selected by phase selector. To demonstrate the promise of this approach the proposed rotor position estimation algorithms are verified by the experiment results or variable spee range.

  • PDF

PFC Controller Design for 3-Phase Modular UPS (3상 모듈형 UPS용 PFC 제어기 설계)

  • Park, Nae Chun;Kim, Sang Hoon;Ji, Jun Keun
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.44-45
    • /
    • 2010
  • In this paper a new PFC Controller for 3-Phase Modular UPS is proposed. The PFC circuit for 3-Phase Modular UPS is implemented using three 1-phase 3-level boost PFC circuits. To control DC output voltage and AC input current, single voltage controller considering imbalance of two capacitor voltages and three independent current controllers are used in proposed PFC controller.

  • PDF

A Low Phase Noise Phase Locked Loop with Current Compensating Scheme (전류보상 기법을 이용한 낮은 위상 잡음 위상고정루프)

  • Song, Youn-Gui;Choi, Young-Shig;Ryu, Ji-Goo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.12 s.354
    • /
    • pp.74-80
    • /
    • 2006
  • This work presents a novel architecture of phase locked loop (PLL) with the current compensating scheme to improve phase noise performance. The proposed PLL has two Charge Pump (CP), main-CP (MCP) and sub-CP (SCP). The smaller SCP current with same time duration but opposite direction of UP/DN MCP current is injected to the loop filter (LF). It suppress the voltage fluctuation of LF. In result, it improves phase noise characteristic. The Proposed PLL has been fabricated with 0.35fm 3.3V CMOS process. Measured phase noise at 1-MHz offset is -103dBc/Hz resulting in a minimum 3dBc/Hz phase noise improvement compared to the conventional PLL.

Current-Programmed Control of Three Phase PWM AC-AC Buck Converter

  • Choi, Nam-Sup;Li, Yulong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.356-361
    • /
    • 2005
  • In this paper, a new scheme of current programmed control for three phase PWM AC-AC converter is presented. Compared to duty-ratio voltage control, current programmed control has several advantages such as reduction of system order and inherent current protection. By considering only the magnitude components, the same scheme in the DC-DC converter can be extended to the three phase PWM AC-AC converter. Sensing the output voltage and the inductor current, an error signal will be generated by comparing the output voltage magnitude with a reference value. Then the error signal will be processed by a PI compensator to generate the current command. The converter switches will the change the state by a periodic clock pulse or at the instants when the inductor current magnitude reaches the current command. As an example case, the buck converter is treated. The converter analysis is carried out by applying the complex DQ circuit transformation to obtain basic physical insight into the converter operation and to establish some important characteristic equations for control purpose. The simulation with Simplorer shows the validity of the proposed scheme and the experimental results support the verification of the design.

  • PDF

Estimation of a circulating current of a three-phase Y-Y-$\Delta$ transformer (3권선 변압기 순환전류 추정 알고리즘)

  • Kang, Yong-Cheol;Lee, Mi-Sun;Lee, Byung-Eun;Jang, Sung-Il;Kim, Yong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.559-560
    • /
    • 2007
  • In the case of the transformers including the delta winding such as a three-phase Y-Y-$\Delta$ transformer, a delta winding current flows in the delta windings. The delta winding current of a three-phase Y-Y-$\Delta$ transformer is decomposed into a non-circulating current and a circulating current. The former can be estimated directly from the line currents, but the latter can not. This paper proposes an estimation method for a circulating current of a Y-Y-$\Delta$ Transformer. A first order differential equation for the circulating current is derived by applying the Kirchhoff's voltage law on the loop of the delta side. The circulating current can be estimated by solving the differential equation. Various test results indicate the algorithm can estimate the circulating current accurately even under over-excitation and magnetic inrush.

  • PDF

Analysis of Current Ripple for Two-Phase Interleaved Boost PFC (2상 인터리브드 부스트 PFC의 전류 리플 해석)

  • Kim, Jung-Hoon;Jeon, Tae-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.3
    • /
    • pp.122-128
    • /
    • 2012
  • An interleaved boost converter has many advantages such as current ripple reduction, switching effective double, etc. Due to these advantages, the interleaved boost converter applies to the power factor correction circuit. However, there are almost no analysis results because the input voltage and current are time-varying system in the power factor correction application. Therefore, in this paper, the current ripples of the power factor correction circuit using single-phase boost dc-dc converter and 2-phase interleaved boost dc-dc converter are compared and analyzed in detail. In order to verify the validity, computer simulation and experimental are performed.

Input Current Characteristics of a Three-Phase Diode Rectifier with Capacitive Filter Under Line Voltage Unbalance Condition

  • Jeong Seung-Gi;Lee Dong-Ki;Park Ki-Won
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.808-815
    • /
    • 2001
  • The three-phase diode rectifier with a capacitive filter is highly sensitive to line voltage unbalance, and may cause significantly unbalanced line currents even under slightly unbalanced voltage condition. This paper presents an analysis of this 'unbalance amplification' effect for an ideal rectifier circuit without ac-and dc-side inductors. The voltage unbalance is modeled by introducing a deviation voltage superimposed on balanced three-phase line voltages. With proper approximations, closed-form expressions for symmetrical components of the line current and current unbalance factor are derived in terms of the voltage unbalance factor, filter reactance, and load current. The validity of analytical predictions is confirmed by simulation.

  • PDF

A New Control Method for Single-Phase Active Power Line Contioners (단상 능동 전력 조절 장치를 위한 새로운 제어기법)

  • 서영조
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.155-158
    • /
    • 2000
  • A new control method for single-phase shunt active power line conditioners(APLC's) operated under zero average power consumption is proposed in this paper. The amplitude of the sinusoidal source current which is in-phase with the source voltage can be determined from the average value of the instantaneous load power. Then the command current for the shunt APLC is obtained by subtraction the source current from the load current. Neither bulky filter nor time-consuming computation is required. The shunt power compensator supplies all the harmonics of he load current and the source only supplies the fundamental component,. Experimental results on a prototype verify the feasibility of the presented scheme,

  • PDF

Control Method for Reducing the THD of Grid Current of Three-Phase Grid-Connected Inverters Under Distorted Grid Voltages

  • Tran, Thanh-Vu;Chun, Tae-Won;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.712-718
    • /
    • 2013
  • This paper proposes a control method for reducing the total harmonic distortion (THD) of the grid current of three-phase grid-connected inverter systems when the grid voltage is distorted. The THD of the grid current caused by grid voltage harmonics is derived by considering the phase delay and magnitude attenuation due to the hardware low-pass filter (LPF). The Cauchy-Schwarz inequality theory is used in order to search more easily for the minimum point of the THD. Both the gain and angle of the compensation voltage at the minimum point of the THD of the grid current are derived with the variation of cut-off frequencies of the hardware LPF. Simulation and experimental results show the validity of the proposed control methods.