• 제목/요약/키워드: current mode

검색결과 3,004건 처리시간 0.035초

펄스 모드로 작동하는 증기냉각 전류 도입선에 관한 연구 (Investigation on vapor-cooled current leads operating in pulse mode)

  • 인세환;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.66-72
    • /
    • 2002
  • This paper describes numerical modeling for thermal characteristic of vapor-cooled current leads under pulse operation. The transient thermal analysis considers the temperature difference between a helium gas (low and a copper lead and temperature dependent properties of helium gas, copper and stainless steel. This numerical modeling was compensated and validated by an experiment with commercially available 100 A vapor-cooled current leads. A proper overloading factor was suggested for the current leads under pulse operation through this modeling, which can significantly reduce heat input to a cryostat.

Decoupling Method Between Digital Signals on FPCB and Mobile Handset Antenna

  • Kim, Joon-Chul;Kim, Hyeong-Dong
    • ETRI Journal
    • /
    • 제33권1호
    • /
    • pp.121-124
    • /
    • 2011
  • Digital harmonics, which may reduce the radio frequency sensitivity of a system, can be coupled with an antenna in a mobile handset. This letter presents a decoupling method for increasing the isolation between digital harmonics on a flexible printed circuit board (FPCB) and an antenna in terms of the ground mode current and the concept of reaction. We model the signal and ground lines in an FPCB as a loop circuit exciting a ground mode current and demonstrate a simple but efficient decoupling method for reducing the excited ground mode current.

슬라이딩 모드제어기와 권선형 유도전동기를 이용한 고조파 및 역률보상 (Harmonic and Power Factor Compensation Using WRIM Based on Sliding Mode Controller)

  • 김승모;김윤호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.7-11
    • /
    • 2002
  • This paper proposes an APF(Active Power Filter) with WRIM(Wounded Rotor Induction Motor) controlled by sliding mode which can compensate harmonic currents generated in a power system. As non-linear loads increase gradually in industry fields, harmonic current generated In the electric power network system also increases. Harmonic current makes a power network current distorted and generates heat, vibration and noise In the power machinery, Many approaches have been applied to compensate harmonic currents generated in the power system. Among various control strategy, in this paper, a sliding mode controlled systems is designed and evaluated. This is a flywheel compensator based on secondary excitation of WRIM(wounded rotor induction motor) with SMC(sliding mode controller). The proposed system uses a flywheel as an energy storage device. The designed control scheme is verified through simulation.

  • PDF

전류모드제어를 위한 연속시간모델의 새로운 유도 방법 (Alternative Derivation of Continuous-Time Model for Current-Mode Control)

  • 정동열;홍성수;최병조;안현식;사공석진
    • 전력전자학회논문지
    • /
    • 제8권2호
    • /
    • pp.137-142
    • /
    • 2003
  • 전류모드제어의 널리 알려진 두가지 연속시간모델이 소신호 예측에서 현저한 차이점을 보인다 따라서, 소신호에서의 불일치의 원인을 명백하게 하려고 한다. 본 논문에서는 전류모드제어를 위한 연속시간모델을 유도하는 다른 방안을 제시한다. 본 논문에서 제안한 전류모드제어모델과 기존의 전류모드제어모델과 모델링 방법의 차이점을 제시하고, 제안된 연속시간모델에 대한 타당성을 검증하기 위해 하드웨어실험과 PWM 블록의 모델에 샘플링효과를 포함하는 알고리즘을 제안하고, 전류루프이득을 시뮬레이션과 하드웨어 실험 결과와 비교, 검토하였다.

Electrically tunable current mode high Q- bandpass filter

  • Tongkulboriboon, Seangrawee;Petchakit, Wijittra;Kiranon, Wiwat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.237-240
    • /
    • 2005
  • A novel current mode high Q bandpass filter with electronically tuable values of Q based on second generation current controlled conveyor CCCIIs is presented. The circuit offers the advantages of using a few passive elements. The center frequency and pole-Q can be independently adjusted by via dc bias current of CCCIIs, It is shown from SPICE simulation that the results agree well with theoretical analysis

  • PDF

PWM 인버어터로 구동되는 유도 전동기의 고주파 누설전류 모델링 및 억제에 관한 연구 (A Study on Modeling and Damping of High-Frequency Leakage Currents in PWM Inverter Feeding an Induction Motor)

  • 이재호;전진휘;홍정표;강필순;박성준;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.18-22
    • /
    • 1998
  • A PWM inverter with an induction motor often has a problem with a high frequency leakage current that flows through stray capacitor between stator windings and a motor frame to ground. This paper presents an equivalent circuit for high frequency leakage currents in PWM inverter feeding an induction motor, which forms an LCR series resonant circuit. A conventional common mode ckoke or reactor in series between the ac terminals of a PWM inverter and those of an ac motor is not effective to reduce the rms and average values of the leakage current, but effective to reduce the peak value. Furthermore, this paper proposes a leakage current damper which is different in damping principle from the conventional common mode choke. It is shown theoretically and experimentally that the leakage current damper is able to reduce the rms value of the leakage current to 25%, where the core used in the leakage current damper is smaller than that of the conventional common-mode choke

  • PDF

영구전류모드를 가지는 초전도 마그네트 시스템의 여자방법 (Energization method of Superconducting Magnet System with Persistent Current Mode)

  • 예정희;나완수;주진호;홍계원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.305-307
    • /
    • 1998
  • One of the merits of superconducting magnet system is that it has persistent current mode, in which the current can be constant without any external power supply. The problem is that when we energize the magnet we can not reach the target current with constant current source, in principle. It needs another energization methods, in which it can be energized with reasonable accuracy and time. This paper suggests two energization methods for a superconducting magnet with persistnet current mode and the comparisons of the two are made with respect to the accuracy and the time.

  • PDF

전류불연속 제어의 고효율 부스트 DC-DC 컨버터에 관한 연구 (A Study on High Efficiency Boost DC-DC Converter of Discontinuous Current Mode Control)

  • 곽동걸;김춘삼
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권9호
    • /
    • pp.431-436
    • /
    • 2005
  • This paper studies a novel boost DC-DC converter operated high efficiency for discontinuous current mode (DCM) control. The converter worked in DCM eliminates the complicated circuit control requirement, reduces a number of components, and reduces the used reactive components size. In the general DCM converter, the switching devices are turned-on the zero current switching (ZCS), and the switching devices must be switched-off at a maximum reactor current. To achieve the zero voltage switching (ZVS) at the switching turn-off, the proposed converter is constructed by using a new loss-less snubber circuit. Soft-switched operation of the proposed boost converter is verified by digital simulation and experimental results. A new boost converter achieves the soft-switching for all switching devices without increasing their voltage and current stresses. The result is that the switching loss is very low and the efficiency of boost DC-DC converter is high.

선형방식과 스위칭 방식의 레귤레이터를 함께 구동하기 위한 Mode Selector (A Mode Selector for Operation with Linear and Switching Regulator)

  • 조한희;박경현;정준모;구용서
    • 전기전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.260-264
    • /
    • 2015
  • 본 논문에서는 부하전류를 감지하여 스위칭 방식과 선형 방식의 레귤레이터를 동작하기 위한 mode selector를 제안한다. 제안된 mode selector는 선형 방식과 스위칭 방식으로의 모드 전환이 가능하며, 경부하 조건에서 낮은 효율을 갖는 스위칭 방식의 레귤레이터의 단점을 보완하고자 제안되었다. 경부하 조건에서는 선형 방식의 레귤레이터로 mode를 전환함으로써 경부하 상태에서도 높은 효율을 제공할 수 있다. 설계한 mode selector는 동부 하이텍의 $0.18{\mu}m$ CMOS 공정을 이용하였다.

국제 핵융합실험로용 VS(Vertical Stabilization) 컨버터의 운전모드 및 보호동작 (Operation modes and Protection of VS(Vertical Stabilization) Converter for International Thermonuclear Experimental Reactor)

  • 조현식;조종민;오종석;서재학;차한주
    • 전력전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.130-136
    • /
    • 2015
  • This study describes the structure and operation modes of vertical stabilization (VS) converter for international thermonuclear experimental reactor (ITER) and proposes a protection method. ITER VS converter supplies voltage (${\pm}1000V$)/current (${\pm}22.5kA$) to superconducting magnets for plasma current vertical stabilization. A four-quadrant operation must be achieved without zero-current discontinuous section. The operation mode of the VS converter is separated in 12-pulse mode, 6-pulse mode and circulation current mode according to the magnitude of the load current. Protection measures, such as bypass and discharge, are proposed for abnormal conditions, such as over current, over voltage, short circuit, and voltage sag. VS converter output voltage is controlled to satisfy voltage response time within 20 msec. Bypass operation is completed within 60 msec and discharge operation is performed successfully. The feasibility of the proposed control algorithm and protection measure is verified by assembling a real controller and implementing a power system including the VS converter in RTDS for a hardware-in-loop (HIL) facility.