• Title/Summary/Keyword: current limiting reactor (CLR)

Search Result 5, Processing Time 0.015 seconds

Analysis on magnetizing characteristics of current limiting reactor using HTSC module

  • Han, Tae Hee;Lim, Sung Hun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.1
    • /
    • pp.15-18
    • /
    • 2018
  • In this paper, the magnetizing characteristics of the current limiting reactor (CLR) using $high-T_C$ superconducting (HTSC) module were analyzed. Since the saturation of iron core comprising the CLR using HTSC module deteriorates its current limiting operation, the design of the CLR using HTSC module considering the magnetizing characteristics is needed. For the analysis on the magnetizing characteristics, the flux linkage and the magnetizing current of this CLR using HTSC module were derived from its electrical equivalent circuit. Through the analysis on the linkage flux versus the magnetizing current, obtained from the short-circuit tests, the suppressing effect of the iron core's saturation was discussed.

Analysis on Current Limiting and Recovery Characteristics of a Trigger Type SFCL as the Composition of the Contact (트리거형 초전도한류기의 접점구성에 따른 전류제한 및 회복특성 분석)

  • Choi, Jong-Soo;Kim, Myoung-Hoo;You, Il-Kyoung;Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.159-164
    • /
    • 2010
  • We experiment to analyze on current limiting and recovery characteristics of trigger type SFCL as the composition of the contact. Generally, some superconductor of SFCL is relatively largely loaded due to limit the fault current by oneself and recovery time is affected until the fault cleared. However, in the fault, the proposal trigger type SFCL transfer the fault current to current limiting reactor(CLR) using power switch so it could reduce the recovery time and load of the superconductor. However, because of applying the additional power switches, that could generate some power loss. Therefore, to solve this problem, we proposed the composition method of the double contact for a trigger type SFCL and analyzed on current limiting and recovery characteristics for ones.

Analysis of Power System Dynamic Security Due to Operation of 345kv CLR (345kv한류리액터 운전에 따른 전력계통 동적안전도 해석)

  • Lee Baek Seok;Kang Dae Eon;Lee Kang Wan
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.24-26
    • /
    • 2004
  • The growing demand for electricity has result in a corresponding increase in power generated and transmitted. As the increase in installed capacity of power system, the fault currents of 345kv system will be increased beyond the interrupting duty of the circuit breakers. The current limiting reactors are used to limit the fault current. The paper presents the result of the transient stability and voltage stability due to install 345kV current limiting reactor to suppress the fault currents.

  • PDF

Specifications of 22.9kV HTS cables and FCLs considering protection systems in Korean power distribution system (국내계통 보호시스템을 고려한 22.9kV 초전도케이블/한류기 설계사양 제안)

  • Lee, Seung-Ryul;Park, Jong-Young;Yoon, Jae-Young;Lee, Byong-Jun;Yang, Byeong-Mo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.50-54
    • /
    • 2009
  • In Korea, 22.9kV 50MVA HTS (High Temperature Superconducting) cables and 630A/3kA hybrid SFCLs (Superconducting Fault Current Limiters) have been or are being developed by LS Cable, LS Industrial System, and Korea Electric Power Research Institute. They will be installed at Icheon 154kV Substation for real-power-distribution-system operation in 2010. This paper proposes specification of current limiting resistor/reactor for the SFCL and fault current condition of the HTS cable for applying the superconducting devices to Korean power distribution system, from the viewpoint of power system protection.

Analysis on the Operation Characteristics and Protection Coordination between the Current Ratio Differential Relay for Line Protection and the Trigger-type SFCL in the Power Transmission System (송전급 초전도한류기의 적용에 따른 선로보호용 비율전류차동계전기의 동작특성 및 보호협조 분석)

  • Cho, Yong-Sun;Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.925-930
    • /
    • 2013
  • The fault current of the power transmission system is greater than that of the power distribution system. Therefore, the introduction of superconducting fault current limiter (SFCL) is more needed to reduce the increased fault current. The trigger-type SFCL consists of the high-temperature superconducting element (HTSC), the current limiting reactor (CLR) and the circuit breaker (CB). The trigger-type SFCL can be used to supplement the disadvantages of the resistive-type SFCL. The operation characteristics of the current ratio differential relay which is usually applied to the protection device of the power transmission system are expected to be affected under fault conditions and the applicability of the trigger-type SFCL. In this paper, we analyzed the operating characteristics, by the fault conditions, between the current ratio differential relay for line protection and the trigger-type SFCL in the power transmission system through the PSCAD/EMTDC simulation.