• 제목/요약/키워드: current lead

검색결과 1,685건 처리시간 0.026초

유도가열에 의한 BGA 솔더 범프의 접합특성에 관한 연구 (Joining characteristics of BGA solder bump by induction heating)

  • 방한서;박현후
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2003년도 추계학술발표대회 개요집
    • /
    • pp.86-88
    • /
    • 2003
  • The characteristic of induction heating solder bump(solder ball: Sn-37Pb, Sn-3.5Ag, Sn-3.0Ag-0.5Cu) has analyzed in this paper. The initial condition of induction heating depends on the time and current. The shape of lead-free solder bump is better than lead solder. The shear strength of lead solder bump has decreased with aging time. The average of shear strength of solder bump is about 10N, 11N, and 11N respectively. The lead-free solder bump's shear strength is better than lead solder and varies irregularly with aging time.

  • PDF

전도냉각형 초전도시스템의 전류도입선 냉각을 위한 열커패시터의 열적해석 (Thermal analysis of a thermal capacitor for the current lead cooling in conduction-cooled superconducting systems)

  • 권기범;양형석;정은수;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.31-34
    • /
    • 2002
  • In this study, thermal analysis of a thermal capacitor, which is used to cool the current lead in conduction-cooled superconducting systems, was done. The temperature difference across a thermal capacitor was calculated by using heat conduction equation. Effect of heat load, total thickness, height and length of a thermal capacitor on the temperature difference were show. Using the results in this work, total thickness and heat height of a thermal capacitor can be determined for given heat load and given temperature difference. This work can be used practically in design for every superconduction system using a current lead.

  • PDF

자동차 변속기 부품 이동의 효율적 관리를 위한 출하관리 시스템 모형 -자동차 부품 제조업을 중심으로- (Shipment Management System Model for Efficient Management of Transferring Automobile Transmission Parts -In Automobile Parts Manufacturing Industry-)

  • 공명달
    • 대한안전경영과학회지
    • /
    • 제18권3호
    • /
    • pp.147-154
    • /
    • 2016
  • This paper suggests a specific model that could efficiently improve the interaction and the interface between MES(Manufacturing Execution System) server and PDA terminal through RFID(Radio Frequency Identification) system and bar-code system in automative transmission shipment place of the finished assembly parts. The proposed model shows that the new method by RF-Tag system can more efficiently perform to reduce processing time and loading time for shipment, compared with the current approach by bar-code system. It is noted in case of the method by RF-Tag that the effects of proposed model are as follows; (a) While the shipping lead time per truck for carrying by the current method was 35 minutes, the shipping lead time by the new method was 15 minutes. (b) While the accuracy for carrying by the current method was 50%, the accuracy by the new method was 99%.

전도냉각되는 1-2kV급 고온초전도 직류리액터 전류도입부의 전기적 절연에 대한 연구 (Study on the Electrical Insulation of Current Lead in the conduction-cooled 1-2kV Class High-Tc Superconducting DC Reactor)

  • 배덕권;안민철;이찬주;정종만;고태국;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.30-34
    • /
    • 2002
  • In this Paper, Insulation of current lead in the conduction-cooled DC reactor for the 1.2kV class 3 high-Tc superconducting fault current limiter(SFCL) is studied. Thermal link which conducts heat energy but insulates electrical energy is selected as a insulating device for the current lead in the conduction-cooled Superconducting DC reactor. It consists of oxide free copper(OFC) sheets, Polyimide films, glass fiberglass reinforced Plastics (GFRP) plates and interfacing material such an indium or thermal compound. Through the test of dielectric strength in L$N_2$, polyimide film thickness of 125 ${\mu}{\textrm}{m}$ is selected as a insulating material. Electrical insulation and heat conduction are contrary to each other. Because of low heat conductivity of insulator and contact area between electrical insulator and heat conductor, thermal resistance of conduction-cooled system is increased. For the reducing of thermal resistance and the reliable contact between Polyimide and OFC, thermal compound or indium can be used As thermal compound layer is weak layer in electrical field, indium is finally selected for the reducing of thermal resistance. Thermal link is successfully passed the test. The testing voltage was AC 2.5kVrms and the testing time was 1 hour.

납축전지의 성능 향상을 위한 양극판의 숙성과 그리드에 관한 연구 (A Study on the Curing of Positive Plate and Grid to Improve the Capacity of the Lead-Acid Batteries)

  • 구본근;정순욱
    • 한국응용과학기술학회지
    • /
    • 제25권1호
    • /
    • pp.41-47
    • /
    • 2008
  • This study was conducted to made a grid alloy (Pb-Ca-Sn-Al) which has a temporary composition ratio in order to improve the efficiency of lead acid batteries. The positive activity material made a 3BS(tri-basic lead sulfate; $3PbO{\cdot}PbSO_4{\cdot}H_2O$) by a low temperature curing and it evaluates the plate efficiency through the life cycle testing. The initial current capacity of low temperature curing plate was excellent but the life cycle was not good (S1). As for the S2 plate, however, the initial current capacity and the life cycle were superior.

염화인-아세트산-숙신산 염 용액에서 납의 전해석출 (Electrodeposition of lead from $PbCl_2$-Acetate-Succinate Solutions)

  • 강탁
    • 한국표면공학회지
    • /
    • 제19권2호
    • /
    • pp.44-50
    • /
    • 1986
  • Effects of cathodic overvoltages on the electrodeposition of lead from electrolyte containing lead chloride, ammonium acetate and sodium succinate was investigated at 20$^{\circ}C$. The use of organic additives, phenol and gelatin was found effective to inhibit the growth of dendritic crystals. At the carthodic overvoltages higher than 0.2V, the lead deposit becames less compact even in the presence of organic additives. The applications of agitation and pulse current promoted compact and shiny deposits.

  • PDF

문어흘림낚시용 친환경 봇돌의 개발과 그 특성 (The development and the characteristics of environmentfriendly sinker for octopus drift-line)

  • 안영일;윤상옥
    • 수산해양기술연구
    • /
    • 제44권3호
    • /
    • pp.184-193
    • /
    • 2008
  • For environment-friendly fishery, the lead sinkers of octopus drift line were developed with the environmentfriendly sinker, and their characteristics and performance were investigated. To make the environmentfriendly sinker, the hydrate ceramic material was developed, and to increase the weight and strength, the iron power was added to it. The fishing hook was machine-made, and standardized, by using 60cm iron wire. For the manufacture of the sinker, the first, the mold was made, and then, hydrate ceramic material and water were quantitatively mixed. The mixture was poured into the mold prepared with a fishing hook already inserted, and had hardened for several hour, before it was taken out of the mold as a complete sinker. The sinkers were made in the 8 types ranging in weight from 150 to 500g, and their specific gravities were diverse from 2.871 to 6.637, which was 0.19 to 0.44 times lower than that of lead. The movement of the environment-friendly sinker by flume tank was possible in the weaker current speed than the similar lead sinker. In the coastal fishing grounds of Gangwon province, the comparison of catching efficiency was made between the improved fishing gears composed of the environment-friendly sinkers and artificial baits, and the current used fishing gears of lead sinkers and pig-fat baits. The result showed the tendency in which the improved fishing gears caught the bigger octopuses than the current used fishing gears. In the quantity and number of the fish catch per unit fishing gear, the improved fishing gear showed a little more catch than the current used fishing gear, regardless of the fishing area. However, the number of the improved fishing gears lost during fishing operation was similar to that of the current used fishing gears.

KSTAR 전류전송제어시스템의 원격운전을 위한 EPICS 기반 제어계 구축 (Implementation of EPICS based control system for KSTAR Current Lead System)

  • 김명규;백설희;김국희;박미경
    • 한국진공학회지
    • /
    • 제17권1호
    • /
    • pp.58-66
    • /
    • 2008
  • KSTAR 전류전송제어시스템은 네트워크기반의 실시간 분산제어시스템으로 EPICS (Experimental Physics and Industrial Control System)를 미들웨어로 채용하여 구축하였다. 전류전송제어시스템은 초전도자석시스템에 전류를 전송하기 위한 시스템으로서 전류전송과 동시에 초전도자석이 초전도상태를 유지하기 위한 냉매의 전송도 담당하고 있다. 주제어실에서의 원격운전을 위하여 EPICS IOC(Input Output Controller) 서버를 현장에 설치하였고 이를 통하여 전류전송제어시스템은 고유의 이름(PV)에 적절한 조작 및 감시 명령을 부여하여 주제어실의 운전화면을 통하여 시스템의 감시 및 조작이 가능하도록 하였다. EPICS와 PLC의 통신을 위하여 ether-ip 드라이버를 이용하여 EPICS IOC를 구축하였으며, 시험 결과 안정성 및 운용성 측면에서 만족할 만한 결과를 획득하였다.

2단냉동기로 전도냉각되는 HTS전류도입선의 열역학 설계 (Thermodynamic Design of HTS Current Leads Conduction-Cooled by 2-Stage Cryocooler)

  • 장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.198-201
    • /
    • 1999
  • An optimal cooling method for HTS(high Tc superconductor) current leads has been analytically sought to minimize the required refrigerator power. The binary current lead is a series combination of a normal metal conductor at the warmer part and an HTS at the colder part. The lead is cooled by direct contacts with a two-stage cryocooler at the joint and at the cold end. It is clearly proven that there exists unique optimal values for the joint temperature and the current density to minimize the refrigerator power per unit current. the actual power input to the cryocooler in the optimal conditions is compared with its thermodynamic limit, and some significant issues in practical design are presented with a useful graphical method.

  • PDF

대규모 그리드 접지전극의 과도접지임피던스의 측정 (The transient grounding impedance measurment of large grid grounding electrodes)

  • 전병욱;이수봉;이봉;이승주;정동철;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2008
  • This paper presents the transient and conventional grounding impedance behaviors of large grid grounding system associated with the injection point of impulse current The measurement methods consider two possible errors in the grounding-system impedances: (1) ground mutual resistance due to current flow through ground from the ground electrode to be measured to the current auxiliary, (2) ac mutual coupling between the current test lead and the potential test lead The test circuit was set to reduce the error factors. The transient grounding impedance depends on the rise time and injection point of impulse current It is effective that grounding conductor is connected to the center of the large grid grounding system.

  • PDF