• Title/Summary/Keyword: current cost

Search Result 3,921, Processing Time 0.029 seconds

A Development of a Framework Cost Estimation Model for the Digital Document Database Construction Projects (지식정보 구축 대가의 개발 : 국가직무표준(National Competency Standards)과의 통합 방안을 중심으로)

  • Kim, Sojung Lucia;Seo, Yong Won;Son, Young-ho
    • Journal of Information Technology Services
    • /
    • v.16 no.3
    • /
    • pp.47-65
    • /
    • 2017
  • The reference guide for the cost of establishing the digital documents has been used as a basis for establishing the budget for the construction of the knowledge information resource. However, due to the abolition of the nominal unit price notification in terms of IT projects, it is necessary to conduct research to convert the standard of the current labor force grade standard to the national incompetency standard (NCS). In this study, we investigate and revise the system and contents of the current knowledge information cost estimation model. In specific, i) we conducted gap analysis of cost estimation model and existing NCS model. As the contents conforming for the construction of the knowledge information resource were not adoptable, we define the description of the construction of the knowledge information resource and to identify the core elements of NCS prior to the improvement of the cost model. ⅱ) then we proposed improve the cost model considering integration with newly proposed NCS model for knowledge information construction job. In order to ensure the validity of the application of NCS development and cost estimation model, the experts reviewed relevant contents and made plans for improvement by using experts from supply and demand groups of various fields of national knowledge informatization projects.

The Impact of Sales and Management Expenses on Firm Value (기업특성에 따른 판매관리비가 기업 가치에 미치는 영향)

  • Son, Jeong-Guen;Bae, Khee-Su
    • Korean Management Science Review
    • /
    • v.34 no.1
    • /
    • pp.71-84
    • /
    • 2017
  • The purpose of this study is to extract the characteristic cost through the time series analysis of each cost from 2003 to 2014, and to grasp the performance and relevance of the enterprise. Therefore, in this section, we analyzed the time-series analysis of selling, administrative, and non-operating expenses as described above. First, depreciation cost, advertising cost, transportation cost, research cost, current research cost, and ordinary development cost were extracted as the variables of interest to be verified in the empirical analysis. However, in the analysis of non-operating expenses, we could not extract the specific cost, but we could grasp the time-series flow of cost data before and after two epochs such as financial crisis and introduction of IFRS obligation. The results of this study show that sales management costs have a positive (+) effect on firm value. Empirical analysis confirms that management is trying to increase or decrease the cost This can be confirmed by the empirical results of this paper. At present, general enterprise accounting is done through ERP system. However, since the ERP system does not have an analysis system for each sales and management cost, the current system has difficulty in knowing the budget item for each cost each time the expenditure resolution for each cost item is made, It is a reality that the expenditure plan must be managed separately and it is inconvenient to keep it. However, if this practical difficulty is solved by the cost analysis system such as sales management cost, the present accounting information system will be further developed. Furthermore, the management will increase the profit item It is thought that coordination actions can also be prevented in advance.

Classification of Grid Connected Transformerless PV Inverters with a Focus on the Leakage Current Characteristics and Extension of Topology Families

  • Ozkan, Ziya;Hava, Ahmet M.
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.256-267
    • /
    • 2015
  • Grid-connected transformerless photovoltaic (PV) inverters (TPVIs) are increasingly dominating the market due to their higher efficiency, lower cost, lighter weight, and reduced size when compared to their transformer based counterparts. However, due to the lack of galvanic isolation in the low voltage grid interconnections of these inverters, the PV systems become vulnerable to leakage currents flowing through the grounded star point of the distribution transformer, the earth, and the distributed parasitic capacitance of the PV modules. These leakage currents are prohibitive, since they constitute an issue for safety, reliability, protection coordination, electromagnetic compatibility, and module lifetime. This paper investigates a wide range of multi-kW range power rating TPVI topologies and classifies them in terms of their leakage current attributes. This systematic classification places most topologies under a small number of classes with basic leakage current attributes. Thus, understanding and evaluating these topologies becomes an easy task. In addition, based on these observations, new topologies with reduced leakage current characteristics are proposed in this paper. Furthermore, the important efficiency and cost determining characteristics of converters are studied to allow design engineers to include cost and efficiency as deciding factors in selecting a converter topology for PV applications.

A Novel MPPT using Single Sensor for Photovoltaic Module Integrated Converter (단일 센서를 사용한 태양광 Module Integrated Converter의 최대전력점 추종 기법)

  • Ji, Young-Hyok;Kim, Young-Ho;Jung, Doo-Yong;Lee, Su-Won;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.263-266
    • /
    • 2009
  • In the photovoltaic applications, MPPT(maximum power point tracking) method is essential due to the non-lineality of photovoltaic output characteristics. To ensure stable tracking response, two sensors are required in conventional popular MPPTs. In modularized PV system as an AC module system, the cost of a sensor can have an effect on entire system cost because a power conditioning device is connected in a PV module. Because only a current sensor is required for proposed MPPT, it is helpful in the cost reduction point of view. In this paper, a novel MPPT using current sensor is proposed In the proposed MPPT, the voltage is derived from sensed current value. The proposed method is verified by simulation results.

  • PDF

A new low-cost asymmetric current-fed energy-recovery circuit for a plasma display panel (PDP을 위한 새로운 저가형 비대칭 전류 주입 에너지 회수 회로)

  • Kim Tae-Sung;Han Sang-Kyoo;Moon Gun-Woo;Youn Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.78-80
    • /
    • 2006
  • A new low-cost asymmetric current-fed energy-recovery circuit (ERC) for a plasma display panel (PDP) is proposed. LC resonant circuit biased by $V_s/2$ and composed of single switch is used as ERC on both sides of the PDP, slow discharging and fast charging times can be employed, and inductor currents are built up before the PDP is charged and discharged. Therefore, it features a low cost, fully charged/discharged PDP, zero voltage switching (ZVS), low electromagnetic interference (EMI), low current stress, no severe voltage notch, and high energy-recovery capability.

  • PDF

Mixture response surface methodology for improving the current operating condition (현재의 공정조건을 향상시키기 위한 혼합물 반응표면 방법론)

  • Lim, Yong-B.
    • Journal of Korean Society for Quality Management
    • /
    • v.38 no.3
    • /
    • pp.413-424
    • /
    • 2010
  • Mixture experiments involve combining ingredients or components of a mixture and the response is a function of the proportions of ingredients which is independent of the total amount of a mixture. The purpose of the mixture experiments is to find the optimum blending at which responses such as the flavor and acceptability are maximized. We assume the quadratic or special cubic canonical polynomial model over the experimental region for a mixture since the current mixture is assumed to be located in the neighborhood of the optimal mixture. The cost of the mixture is proportional to the cost of the ingredients of the mixture and is the linear function of the proportions of the ingredients. In this paper, we propose mixture response surface methods to develop a mixture such that the cost is down more than ten percent as well as mean responses are as good as those from the current mixture. The proposed methods are illustrated with the well known the flare experimental data described by McLean and Anderson(1966).

Low-cost crowbar system and protection scheme in capacitor bank module (커패시터 뱅크 모듈 구성에 있어서 경제적인 크로바 시스템과 보호회로)

  • Rim, Geun-Hie;Cho, Chu-Hyun;Lee, Hong-Sik;Pavlov, E.P.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2089-2091
    • /
    • 2000
  • Pulsed power systems consist of a capacitor bank, an isolated high-voltage charging power-supply, high-current bus-work for charging and discharging and a control system. In such pulsed power systems, the operating-lifetime of the capacitors is closely dependent on the voltage reversal. Hence, most capacitor-discharging systems includes crowbar circuits. The crowbar circuit prevents the capacitor recharging with reverse voltage. Usually it consists of crowbar resistors and high pulse-current diode-stacks connected in series. The requirements for the diode-stacks are fast-recovery time and high-voltage and large-current ratings, which results in the high cost of the pulsed-power system. This paper presents a protection scheme of a charging and discharging system of a 500kJ capacitor bank using a low-cost crowbar circuit and safety-fuses.

  • PDF

Dual Path Magnetic-Coupled AC-PDP Sustain Driver with Low Switching Loss

  • Lee Jun-Young
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.205-213
    • /
    • 2006
  • A cost-effective magnetic-coupled AC-PDP sustain driver with low switching loss is proposed. The transformer reduces current stress in the energy recovery switches which affects circuit cost and reliability. The turns-ratio can be used to adjust the sustain pulse slopes which affect gas discharge uniformity. Dividing the recovery paths prevents abrupt changes in the output capacitance and thereby switching losses of the recovery switches is reduced. In addition, the proposed circuit has a more simple structure because it does not use the recovery path diodes which also afford a large recovery current. By reducing the current stress and device count in the energy recovery circuit, the proposed driver may have decreased circuit cost and improved circuit reliability.

Low-Cost Single-Phase to Three-Phase PWM Converters for Induction Motor Drives (유도전동기 구동을 위한 저가형 단상-3상 AC/DC/AC PWM 컨버터)

  • Kim Tae-Yun;Lee Dong-Choon;Seok Jul-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.201-204
    • /
    • 2001
  • In this paper, a single-phase to three-phase PWM converter topology using six switches only for low cost induction motor drive is proposed. The converter topology is of lower cost than the conventional one, which gives sinusoidal input current, unity power factor, dc output voltage control and bidirectional power flow In addition, the source voltage sensor is eliminated by controlling the deviation between the model current and the system current to be zero. The performance of the proposed converter has been demonstrated through the computer simulation.

  • PDF

A Brushless DC Motor Drive System and Phase Current Estimation Method For Active Knee Prothesis (동력의지를 위한 BLDCM 구동 시스템 및 상전류 추정 기법)

  • Nam, K.J.;Choi, Y.B.;Jung, D.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.7-12
    • /
    • 2013
  • In this paper, we propose a brushless DC motor drive system for active knee prosthesis and low-cost estimation method for phase current from DC-link current. To control motor torque directly, current sensing is very important and current sensing point should be synchronized with voltage switching command to minimize the effect of switching noise in current measurement, For maintaining small form factor, simplifying control schemes and achieving low-cost system, control schemes using DC-link current are used. Moreover, we incorporated phase current estimation method using analog MUX for minimizing current estimation error between DC-link current and phase current. The validity of the proposed system is verified through experimental works.

  • PDF