A Case Study on Building Cost Management Systems in a Valve Manufacturing Company (주조밸브제조업의 원가계산시스템 설계사례)

  • 박무현;도상호;배주한
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.55
    • /
    • pp.51-71
    • /
    • 2000
  • A case of company manufacturing industrial valves is studied. To survive the fierce competition in the low-volume, high-complexity production environment, the company needs accurate information on the cost of its products. Current cost accounting system which allocates production costs based on the weights of intermediates and final products cannot provide accurate cost information that managers really need. Data on the company's cost structure and production processes were reviewed and managers were interviewed before problems with the current costing system were identified. Activity-based costing (ABC) system as well as an improved traditional costing system is considered to replace the current system. A prototype of ABC system is developed to better represent the relationships among the cost drivers, activities, and products.

  • PDF

A Study on SOA Dimming Driver with Current Pattern Design Capability (전류 패턴의 설계가 가능한 SOA Dimming Driver에 관한 연구)

  • Lee, Juchan;Eom, Jinseob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.22-28
    • /
    • 2013
  • In this paper, the low cost SOA Dimming Driver which consisted of LabVIEW programming part capable of current pattern design, DAQ module for analog voltage output, and voltage to current converter has realized. The output current(possible to 3A) from the Driver was clearly constant without ripple and also showed no variance until 1mA unit for a long time operation. The proposed low cost Driver can replace the previous high cost SOA Drivers for wavelength swept lasers fully and provide the convenience and safety of auto-supplying a designed current pattern.

The Analysis of Current Situation of the Building Precision Safety Inspection and Precision Safety Diagnosis Cost from Practitioners Viewpoint (실무자 관점에서의 건축물 정밀안전점검 및 정밀안전진단 실행대가 현황분석)

  • Lee, Jong-Phil;Lim, Nam-Gi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.37-41
    • /
    • 2018
  • Recently, interest in the safety and maintenance of the structures is growing. However, due to the low-cost order placed by the ordering organization, the safety diagnosis specialized institution becomes insolvent and many problems have arisen due to insufficient inspection and diagnosis. Therefore, in this study, the current status of bid cost was examined through the survey of the practitioners and case analysis. As a result, Precision safety inspection is deemed that it is necessary to increase the efficiency of the criteria cost and to strengthen the rigidity of the criteria cost rather than adjusting the criteria cost. Precision safety diagnosis, the criteria cost for structures with a floor area of less than $10,000m^2$ is lowered to 80 % from the current standard. For structures larger than that, the current criteria cost are applied, but it is deemed necessary to strengthen the rigidity of the criteria cost.

PROCESS RESEARCH FOR DEVELOPMENT OF STRUCTURAL COST ESTIMATING MODEL BASED QUANTITY - FOCUSED ON PUBLIC OFFICE BUILDING PROJECT -

  • Soo-Min Kim;Jung-Kyu Seo;Sung-Uk Kim;Chang-Hyun Shin;Yung-Jin Kim;Jae-Youl Chun
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1170-1175
    • /
    • 2009
  • When managers estimate exact construction cost at early stage and design phase, they can reduce construction cost in a more efficient way than to predict at construction stage. But, the current of public construction cost estimation and management is concentrated almost after detailed design phase. Therefore, construction cost management in design development phase to generally use approximate estimating is not correct. Also, the existing construction cost used the method that estimated by gross floor area-based cost estimates at design development phase. So, it is difficult to show the specific amount of materials and basis about the estimated cost of the construction. This study derived problems and limits of construction management at design development phase in case of public office building project through review of literature and current survey, and suggested estimating process model process of structural construction cost go improve these matters.

  • PDF

Voltage Angle Control of Surface Permanent Magnet Synchronous Motor for Low-Cost Applications

  • Lee, Kwang-Woon;Kim, Guechol
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.716-722
    • /
    • 2018
  • This paper presents a voltage angle control strategy for surface permanent magnet synchronous motor (SPMSM) drives used in low-cost applications, wherein a current vector control is not employed. In the proposed method, the current vector control scheme, which requires high precision phase-current sensing units and a fast calculation capability of a motor drive controller, is replaced with the voltage angle controller. The proposed voltage angle controller calculates a d-axis voltage command to make the d-axis current zero by using a simple equation obtained from the voltage equation of SPMSM. The proposed method shows performance similar to the current vector controlled SPMSM drive during steady-states and its structure is very simple and thus it can be easily implemented with a low-cost microcontroller. The effectiveness of the proposed method is verified through simulations and experiments.

Power Factor Correction of Single-phase Boost Converter for Low-cost Type UPS Configuration (저 가격형 UPS를 구성하기 위한 단상 부스트 컨버터의 고 역률 제어)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.3
    • /
    • pp.145-150
    • /
    • 2013
  • A novel AC to DC PWM converters with unity input power factor are proposed to overcome the above shortcoming. The main function of these converters is to shape the input line current to force it exactly in phase with the input AC voltage. Therefore, the input power factor can be improved to near unity and the input current harmonics can be eliminated. In this paper, half-bridge converter with two active switches and two diodes are utilized for low-cost type UPS configuration. By having only two semiconductors in the current path at any time, losses can be reduced over the conventional boost topology. Also, this converter provides controllable dc-link voltage, high power factor, and low cost type converter by simple power circuits. Simulation results show that the proposed half-bridge converter/inverter control technique can be applied to single-phase low-cost type UPS systems successfully.

Cost-Efficient and Automatic Large Volume Data Acquisition Method for On-Chip Random Process Variation Measurement

  • Lee, Sooeun;Han, Seungho;Lee, Ikho;Sim, Jae-Yoon;Park, Hong-June;Kim, Byungsub
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.2
    • /
    • pp.184-193
    • /
    • 2015
  • This paper proposes a cost-efficient and automatic method for large data acquisition from a test chip without expensive equipment to characterize random process variation in an integrated circuit. Our method requires only a test chip, a personal computer, a cheap digital-to-analog converter, a controller and multimeters, and thus large volume measurement can be performed on an office desk at low cost. To demonstrate the proposed method, we designed a test chip with a current model logic driver and an array of 128 current mirrors that mimic the random process variation of the driver's tail current mirror. Using our method, we characterized the random process variation of the driver's voltage due to the random process variation on the driver's tail current mirror from large volume measurement data. The statistical characteristics of the driver's output voltage calculated from the measured data are compared with Monte Carlo simulation. The difference between the measured and the simulated averages and standard deviations are less than 20% showing that we can easily characterize the random process variation at low cost by using our cost-efficient automatic large data acquisition method.

A 6.6kW Low Cost Interleaved Bridgeless PFC Converter for Electric Vehicle Charger Application (전기자동차 응용을 위한 6.6KW 저가형 브리지 없는 인터리빙 방식의 역률보상 컨버터)

  • Do, An-Ban-Tu-An;Choe, U-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.24-25
    • /
    • 2017
  • In this paper, a low cost bridgeless interleaved power factor correction topology for electric vehicle charger application is proposed. With the proposed topology the number of switches, inductors, current sensors and associated circuits can be reduced, thereby reducing the cost of the system as compared to the conventional bridgeless PFC circuit. The reduced input current ripple by the proposed interleaved topology makes it suitable for high power applications such as electric vehicle chargers since it can reduce the size of the inductor core and the Electro Magnetic Interference (EMI) problem. In the proposed topology only one current sensor is required. All the boost inductor currents can be reconstructed by sampling the output current and used to control the input current. Therefore the typical problem caused by the unequal current gain of each current sensor inherently does not exist in the proposed topology. In addition the current sharing between converters can be achieved more accurately and the high frequency distortion is decreased. The performance of the proposed converter is verified by the experimental results with a prototype of 6.6kW bridgeless interleaved PFC circuit.

  • PDF

Cost Analysis of Home Care with Activity-Based Costing(ABC) (활동기준원가계산[ABC]을 적용한 가정 간호 원가 분석)

  • Lee Su-Jeong
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.6
    • /
    • pp.1117-1128
    • /
    • 2004
  • Purpose: This study was carried out to substantiate the application process of activity-based costing on the current cost of hospital home care (HHC) service. The study materials were documents, 120 client charts, health insurance demand bills, salary of 215 HHC nurses, operating expense, 6 HHC agencies, and 31 HHC nurses. Method: The research was carried out by analyzing the HHC activities and then collecting labor and operating expenses. For resource drivers, HHC activity performance time and workload were studied. For activity drivers, the number of HHC activity performances and the activity number of visits were studied. Result: The HHC activities were classified into 70 activities. In resource, the labor cost was 245₩per minute, operating cost was 9,570₩ per visit and traffic expense was an average of 12,750₩. In resource drivers, education and training had the longest time of 67 minutes. Average length of performance for activities was 13.7 minutes. The workload was applied as a relative value. The average cost of HHC was 62,741₩ and the cost ranged from 55,560₩ to 74,016₩. Conclusion: The fixed base rate for a visit in the current HHC medical fee should be increased. Exclusion from the current fee structure or flexible operation of traveling expenses should be reviewed.

High Performance and Low Cost Single Switch Current-fed Energy Recovery Circuits for AC Plasma Display Panels

  • Han Sang-Kyoo;Youn Myung-Joong
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.253-263
    • /
    • 2006
  • A high performance and low cost single switch current fed energy recovery circuit (ERC) for an alternating current (AC) plasma display panel (PDP) is proposed. Since it is composed of only one power switch compared with the conventional circuit consisting of four power switches and two large energy recovery capacitors, the ERC features a simpler structure and lower cost. Furthermore, since all power switches can be switched under soft switching operating conditions, the proposed circuit has desirable merits such as increased reliability and low switching loss. Specifically, there are no serious voltage notches across the PDP with the aid of gas discharge current compensation, which can greatly reduce the current stress of all inverter switches, and provide those switches with the turn on timing margin. To confirm the validity of proposed circuit, its operation and performance were verified on a prototype for 7-inch test PDP.