• Title/Summary/Keyword: crushing load

Search Result 120, Processing Time 0.027 seconds

Analytical Study on Flexural Behavior of Concrete Member using Heavyweight Waste Glass as Fine Aggregate (고밀도 폐유리를 잔골재로 사용한 RC 부재의 휨거동에 관한 해석적 연구)

  • Cha, Kyoung-Moon;Choi, So-Yoeng;Kim, Il-Sun;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.88-96
    • /
    • 2020
  • It were found that the heavyweight waste glass can be used as a construction materials including concrete from previous experimental studies. In this study, in order to evaluate the structural behavior of RC members using heavyweight waste glass as fine aggregate, a flexural behavior test was performed. And then, its results were compared with those obtained from non-linear finite element model analysis. From the results, when the heavyweight waste glass as fine aggregate in RC member, the area of compressive crushing and the number of cracks increased, however, the mean of cracking spacing decreased. Also it had reduced the ductility at high loading stage. For this reason, the same analysis method about the RC member using natural sand as fine aggregate did not predict the initial stiffness, yield load and maximum load on the flexural behavior of the RC members using heavyweight waste glass as fine aggregate. On the other hand, when it is analytically implemented the reduction of neutral axis depth due to developed compression crushing, the results of non-linear finite element analysis could be predicted the experimental results, relatively well.

Strength and behaviour of reinforced SCC wall panels in one-way action

  • Ganesan, N.;Indiraa, P.V.;Prasad, S. Rajendra
    • Structural Engineering and Mechanics
    • /
    • v.36 no.1
    • /
    • pp.1-18
    • /
    • 2010
  • A total of 28 wall panels were cast and tested under uniformly distributed axial load in one-way in-plane action to study the effect of slenderness ratio (SR) and aspect ratio (AR) on the ultimate load. Two concrete formulations, normal concrete (NC) and self compacting concrete (SCC), were used for the casting of wall panels. Out of 28 wall panels, 12 were made of NC and the remaining 16 panels were of SCC. All the 12 NC panels and 12 out of 16 SCC panels were used to study the influence of SR and the remaining 4 SCC panels were tested to study the effect of AR on the ultimate load. A brief review of studies available in literature on the strength and behaviour of reinforced concrete (RC) wall panels is presented. Load-deformation response was recorded and analyzed. The ultimate load of SCC wall panels decreases non-linearly with the increase in SR and decreases linearly with increasing values of AR. Based on this study a method is proposed to predict the ultimate load of reinforced SCC wall panels. The modified method includes the effect of SR, AR and concrete strength.

The Energy Absorption Control Characteristics of Al Thin-walled Tubes for Crashworthiness Enhancement (충돌성능 향상을 위한 Al 박육부재의 에너지흡수 제어특성)

  • Yang, Yong-Jun;Kim, Sun-Kyu;Yang, In-Young;Sim, Jae-Ki
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.4
    • /
    • pp.81-87
    • /
    • 2008
  • In this study, concerns the crashworthiness of the widely used vehicle structure, square thin-walled tubes, which are excellent on the point of the energy absorbing capacity. An experimental investigation was carried out to study the energy absorption characteristics of thin-walled square tubes subjected to dynamic crushing by axial loading to develop the optimum structural members. The impact velocity was tested in the rage $4.698{\sim}8.2m/s$. To efficiently review the collapse characteristics of these sections, the simulation have been carried out using explicit FEM package, LS-DYNA. The solutions compared with results the impact collapse experiment. Here, the controller are introduced to improve and control the absorbed energy of thin-walled square tubes in this paper. To predict and control the energy absorption, we designed it in consideration to the it's influence, height, thickness, wide ratio in this study. When the controller used, the experimental results of crushing of square tubes controlled by the controller's elements showed a good candidate for a controllable energy absorption capability in impact axial crushing.

Physical, Mechanical and Durability Properties of the Quartzite Units of Central Nepal Lesser Himalaya

  • Dinesh Raj Sharma;Naresh Kazi Tamrakar;Upendra Baral
    • The Journal of Engineering Geology
    • /
    • v.34 no.1
    • /
    • pp.67-105
    • /
    • 2024
  • This study compares the quartzites of four quartzite units: The Fagfog Quartzite, Dunga Quartzite (member of the Robang Formation), Pandrang Quartzite (member of the Kalitar Formation) and the Chisapani Quartzite. The analysis shows variations in flakiness and elongation, as the Fagfog Quartzite displays low flakiness whereas the Pandrang and the Chisapani have moderate and the Dunga Quartzite has shown variations. The density values of the four quartzite units remain consistent, indicating uniform physical properties and porosity levels. However, bulk density values differ among the quartzites, suggesting variations in particle arrangement, porosity, and density. Regarding strength measures, the Pandrang and the Chisapani Quartzite have higher strength characteristics as compared to the Fagfog and the Dunga Quartzites. The Pandrang Quartzite has the highest average point load strength index, classifying it as "Extremely Strong". The resistance to impact and crushing forces varies among the quartzites, with lower Aggregate Impact Value (AIV) and Aggregate Crushing Value (ACV) indicating higher strength and durability. Durability tests show that the Fagfog Quartzite has high durability against slaking, with a slight decrease observed after the fifth cycle. The Dunga Quartzite shows varying degrees of weathering, while the Pandrang and the Chisapani Quartzite have minimal weight changes, indicating strong resistance to weathering. Magnesium sulfate soundness tests indicate high durability and resistance to degradation for all four units. The Los Angeles abrasion value (LAAV) tests indicate favorable resistance to abrasion for the majority of the Fagfog, Dunga, and the Pandrang Quartzites samples, while Chisapani Quartzite shows more variability in LAAV values. The Pandrang Quartzite shows a higher proportion of elongated particles but lower flakiness index values as compared to Fagfog and Dunga Quartzites while Chisapani Quartzite stands out with a significantly higher presence of flaky particles and lower elongation index values. Mechanically, the Fagfog and Dunga Quartzite show higher strength and better resistance to abrasion and freeze and thaw. The Pandrang Quartzite shows moderate resistance to crushing and sudden effect, while the Chisapani Quartzite has variable resistance to effect. This comparative study emphasizes the diversity and complexity of quartzite rock types, showing the need for comprehensive characterization and assessment to determine their suitability for specific applications.

Bending Behaviors of Stainless Steel Tube Filled with Al5Si4Cu4Mg Closed Cell Aluminum Alloy Foam (발포 Al5Si4Cu4Mg 알루미늄 합금이 충진된 304 스테인리스강 원통의 굽힘저항 특성)

  • Kim, Am-Kee;Lee, Hyo-Jin;Cho, Seong-Seock
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1686-1694
    • /
    • 2003
  • The foam-filled tube beams can be used for the front rail and firewall structures to absorb impact energy during frontal or side collision of vehicles. In the case of side collision where bending is involved in the crushing mechanism, the foam filler would be effective in maintaining progressive crushing of the thin-walled structures so that much impact energy could be absorbed. In this study, bending behaviors of the closed-cell-aluminum-alloy-foam-filled stainless steel tube were investigated. The various foam-filled specimens including piecewise fillers were prepared and tested. The aluminum-alloy-foam filling offered the significant increase of bending resistance. Their suppression of the inward fold formation at the compression flange as well as the multiple propagating folds led to the increase of load carrying capacity of specimens. Moreover, the piecewise foams would provide the easier way to fill the thin-walled shell structures without the drawback of strength.

Earthquake resistance of structural walls confined by conventional tie hoops and steel fiber reinforced concrete

  • Eom, Taesung;Kang, Sumin;Kim, Okkyue
    • Earthquakes and Structures
    • /
    • v.7 no.5
    • /
    • pp.843-859
    • /
    • 2014
  • In the present study, the seismic performance of structural walls with boundary elements confined by conventional tie hoops and steel fiber concrete (SFC) was investigated. Cyclic lateral loading tests on four wall specimens under constant axial load were performed. The primary test parameters considered were the spacing of boundary element transverse reinforcement and the use of steel fiber concrete. Test results showed that the wall specimen with boundary elements complying with ACI 318-11 21.9.6 failed at a high drift ratio of 4.5% due to concrete crushing and re-bar buckling. For the specimens where SFC was selectively used in the plastic hinge region, the spalling and crushing of concrete were substantially alleviated. However, sliding shear failure occurred at the interface of SFC and plain concrete at a moderate drift ratio of 3.0% as tensile plastic strains of longitudinal bars were accumulated during cyclic loading. The behaviors of wall specimens were examined through nonlinear section analysis adopting the stress-strain relationships of confined concrete and SFC.

Experimental Study on the Flexural Capacity of the U-Flanged Truss Hybrid Beam (U-플랜지 트러스 복합보의 휨 내력에 대한 실험 연구)

  • Oh, Myoung Ho;Kim, Young Ho;Kim, Myeong Han
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.4
    • /
    • pp.123-130
    • /
    • 2018
  • U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars welded on the upper and lower sides. The hybrid beam with U-flanged steel truss is made in the construction site through pouring the concrete, and designated as U-flanged truss hybrid beam. In this study the structural experiments on the 4 hybrid beams with the proposed basic shapes were performed, and the flexural capacities from the tests were compared with those from the theoretical approach. The failure modes of each specimen were quite similar. The peak load was reached with the ductile behavior after yielding, and the failure occurred through the concrete crushing. The considerable increasement of deformation was observed up to the concrete crushing. The composite action of concrete and steel member was considered to be reliable from the behavior of specimens. The flexural strength of hybrid beam has been evaluated exactly using the calculation method applied in the boubly reinforced concrete beam. The placement of additional rebars in the bottom instead of upper side is proposed for the efficient design of U-flanged truss hybrid beam.

Effectiveness of fibers and binders in high-strength concrete under chemical corrosion

  • Nematzadeh, Mahdi;Fallah-Valukolaee, Saber
    • Structural Engineering and Mechanics
    • /
    • v.64 no.2
    • /
    • pp.243-257
    • /
    • 2017
  • Investigating the properties and durability of high-strength concrete exposed to sulfuric acid attack for the purpose of its application in structures exposed to this acid is of outmost importance. In this research, the resistance and durability of high-strength concrete containing macro-polymeric or steel fibers together with the pozzolans of silica fume or nano-silica against sulfuric acid attack are explored. To accomplish this goal, in total, 108 high-strength concrete specimens were made with 9 different mix designs containing macro-polymeric and steel fibers at the volume fractions of 0.5, 0.75, and 1.0%, as well as the pozzolans of silica fume and nano-silica with the replacement levels of 10 and 2%, respectively. After placing the specimens inside a 5% sulfuric acid solution in the periods of 7, 21, and 63 days of immersion, the effect of adding the fibers and pozzolans on the compressive properties, ultrasonic pulse velocity (UPV), and weight loss of high-strength concrete was investigated and the respective results were compared with those of the reference specimens. The obtained results suggest the dependency of the resistance and durability loss of high-strength concrete against sulfuric acid attack to the properties of fibers as well as their fraction in concrete volume. Moreover, compared with using nano-silica, using silica fume in the fibrous concrete mix leads to more durable specimens against sulfuric acid attack. Finally, an optimum solution for the design parameters where the crushing load of high-strength fibrous concrete is maximized was found using response surface method (RSM).

Experimental and analytical studies on one-way concrete slabs reinforced with GFRP molded gratings

  • Mehrdad, Shokrieh Mahmood;Mohammad, Heidari-Rarani
    • Steel and Composite Structures
    • /
    • v.9 no.6
    • /
    • pp.569-584
    • /
    • 2009
  • Corrosion of steel rebars in bridge decks which are faced to harsh conditions, is a common problem in construction industries due to the porosity of concrete. In this research, the behavior of one-way concrete slabs reinforced with Glass fiber reinforced polymer (GFRP) molded grating is investigated both theoretically and experimentally. In the analytical method, a closed-form solution for load-deflection behavior of a slab under four-point bending condition is developed by considering a concrete slab as an orthotropic plate and defining stiffness coefficients in principal directions. The available formulation for concrete reinforced with steel is expanded for concrete reinforced with GFRP molded grating to predict ultimate failure load. In finite element modeling, an exact nonlinear behavior of concrete along with a 3-D failure criterion for cracking and crushing are considered in order to estimate the ultimate failure load and the initial cracking load. Eight concrete slabs reinforced with steel and GFRP grating in various thicknesses are also tested to verify the results. The obtained results from the models and experiments are relatively satisfactory.

Influence of Extraneous Deformation on the Toughness of Fiber Reinforced Concrete (외부변형이 섬유보강콘크리트의 인성에 미치는 영향)

  • Kim, Kyoung-Soo;Ko, Young-Zoo;Lim, Jeong-Whan;Bae, Ju-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.1
    • /
    • pp.111-120
    • /
    • 2000
  • This study discusses the issues related to the accuracy of deflection measurement in the testing of FRC. Some deflection methods may include large extraneous deformations. such as local crushing at the loading points, elastic and inelastic deformations of the loading fixture, etc. A faulty load-deflection curve will be obtained if an unstable deflection measuring system is used, and incorrect toughness evaluation can be reached on the basis of this faulty curve. In this paper, the discussion will focus on the effects of the deflection measuring system on both the measurement of the load-deflection response of FRC and the evaluation of FRC toughness. It is observed that ASTM toughness indices which is based on measuring deflection at first cracking is influenced significantly by extraneous deformation in deflection measurement. But extraneous deformation in deflection measurement result in negligible errors in toughness evaluation using JSCE and JCI definition. However, in order to evaluate toughness accuracy, it is desirable to use net load-deflection curve eliminated extraneous deformation.

  • PDF