• Title/Summary/Keyword: crosslinked-polymer

Search Result 266, Processing Time 0.025 seconds

Development of Crosslinked Sulfonated Poly(ether sulfone)s as Novel Polymer Electrolyte Membranes (새로운 연료전지용 술폰화된 PES계 가교 고분자 전해질 막의 개발)

  • Oh, Young-Seok;Lee, Myung-Gun;Kim, Tae-Hyun
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.3
    • /
    • pp.345-354
    • /
    • 2009
  • Sulfonated poly(ether sulfone)s (PESs) with a network structure were prepared by heat-induced crosslinking of the allyl-terminated telechelic sulfone polymers using a bisazide and their structure was analyzed by $^1H$ NMR. Having both uniform distribution of the hydrophilic conductive sites and controlled hydrophobic nature by minimized crosslinking, the crosslinked polymer (PES-60) membrane offered excellent proton conductivity at high temperature with a good thermal stability. In addition, selectivity of the crosslinked membrane (PES-60) was more than three times than that of Nafion$^{(R)}$.

Crosslinking Characteristics of High Density Polyethylene by Reactive Melt Processing (반응 용융 가공에 의한 고밀도 폴리에틸렌의 가교 특성 연구)

  • Lee Jong Rok;Lee Dong Gun;Hong Soon Man;Kang Ho-Jong
    • Polymer(Korea)
    • /
    • v.29 no.4
    • /
    • pp.385-391
    • /
    • 2005
  • Reactive melt processing has been carried out to investigate crosslinking characteristics of high density polyethylene OTDPE) with dicummyl peroxide (DCP) and perbutyle peroxide (PBP). The increase of torque in the internal mixer indicated that the crosslinking in HDPE has been occurred by peroxides. As a result, the substantial decrease of density, melting temperature, and melt enthalpy were found while the melt viscosity increased in partially crosslinked HDPE. In the mechanical properties of partially crosslinked HDPE, the increase of maximum strength and the decrease in elongation at break were clearly noticed and these were more pronounced when PBP was applied as a crosslinking agent. It seems that the maximum strength was obtained with reactive processing temperature at $150^{circ}C$, however, the mixing time did not affect to the strength of partially crosslinked HDPE.

Drug Release Characteristics of Crosslinked Poly(alkylene oxide) Hydrogels (가교된 폴리 알킬렌 옥사이드 하이드로겔의 약물방출 특성)

  • Kim, Shin-Jeong;Lee, Seung-Jin
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.2
    • /
    • pp.91-95
    • /
    • 1991
  • Polyethylene glycol, polypropylene glycol and block copolymer of ethylene glycol and propylene glycol were crosslinked by triisocyanate to form water swellable, rubbery polymer. The equilibrium swelling of the hydrogels ranged from 3% to 60% according to the hydrophobic-hydrophilic properties of the prepolymers. Model drugs, sodium salicylate and prednisolone were incorporated in the polymer matrices by swelling loading. Physical properties of the drugs affected the drug release mechanisms due to the change in the swelling behaviors of the polymeric devices. Zero order release was observed in the case of relatively hydrophobic polymer matrices.

  • PDF

Synthesis of Crosslinked Poly(POEM-co-AMPSLi-co-GMA) Electrolytes and Physicochemical Properties (가교결합형 poly(POEM-co-AMPSLi-co-GMA) 전해질의 합성과 물리화학적 특성)

  • Choi, Da-In;Ryu, Sang-Woog
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.1
    • /
    • pp.65-70
    • /
    • 2014
  • In this study, crosslinked poly(POEM-co-AMPSLi-co-GMA)s were prepared by epoxy coupling of GMA after radical copolymerization of AMPS, POEM and GMA followed by acid-base titration reaction between sulfonic acid of AMPS and $Li_2CO_3$. It was observed that the crystalline melting temperature of POEM was effected by mol% of components and shifted to lower value by lithiation of AMPS group. The ionic conductivity of crosslinked polymer electrolyte was decreased by addition of GMA but maintained over $1.0{\times}10^{-6}S\;cm^{-1}$ until 16 mol%. Particularly, the self-doped polymer electrolyte with 2 mol% of GMA showed its ionic conductivity as high as $4.08{\times}10^{-6}S\;cm^{-1}$ at room temperature and electrochemical stability up to 6 V. In addition, 0.11 MPa of modulus and 270% of elongation were obtained from the free standing film of crosslinked polymer electrolyte.

Molecular Design and Characterization of Biodegradable Crosslinked Copolyesters (생분해성 가교 공중합에스테르의 분자설계 및 특성 연구)

  • Sung, Yong-Kiel;Han, Seung-Jun
    • Polymer(Korea)
    • /
    • v.25 no.1
    • /
    • pp.108-114
    • /
    • 2001
  • Crosslinked poly(glycerol-co-malate)s were synthesized from L-malic acid in Krebs cycle and glycerol. The synthesized polymer was identified by FT-IR spectroscopy. Swelling degrees of the copolymer hydrogels were increased with an increase in pH of the aqueous solution. Hydrolytic behaviors of the crosslinked copolymers were investigated in various pH buffer solutions at 37${\circ}C$. The Hydrolysis of the copolymers proceeded faster with increasing pH of the aqueous solution. Releasing behaviors of the model drug such as diclofenac monosodium salt were also measured in various pH aqueous solutions at 37${\circ}C$. The release concentration of diclofenac monosodium salt from the hydrogel systems was increased with increasing pH. These facts indicate that the unreacted carboxyl and hydroxyl groups in the copolymers are greatly affected by pH in the conditions.

  • PDF

Synthesis and Properties of Liquid Crystal Compounds and Epoxy Resin Based Side Chain Liquid Crystal Polymers II. Linear and Crosslinked Epoxy LC Polymers (방향족 액정동족체 및 Epoxy형 측쇄 액정고분자의 합성 및 성질 II. 선형 및 가교형 측쇄 액정고분자)

  • Ahn, Wonsool;Chang, Jin Gyu;Keum, Chang Dae;Park, Lee Soon
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.71-75
    • /
    • 1998
  • Liquid crystalline compounds with amine terminal group and related linear and cross-linked liquid crystal polymers with epoxy resin structure were synthesized and characterized to develope matrix materials for polymer dispersed liquid display applications. Both linear and crosslinked side chain type liquid crystal polymers made with aromatic amine mesogens and ethylene glycol diglycidyl ether exhibited nematic texture as shown by polarized optical microscope(POM) and their transition temperatures were determined both by DSC and POM. Liquid crystal polymer samples also showed even-odd effect as the spacer length of aromatic amine mesogens were varied, however, the effect was samller than that of low molecular weight mesogens. Changes of nematic-to-isotropic transition($T_{NI}$) of crosslinked type polymer liquid crystals were also disscussed in relation to the concentration change of crosslinking agent 1,10-diaminodecane.

  • PDF

Blood Compatibility of Polyurethane-poly(vinyl alcohol) Polymer Blends (폴리우레탄-폴리비닐알콜 블렌드의 혈액적합성)

  • 김승수;유영미;신재섭;정규식
    • Polymer(Korea)
    • /
    • v.24 no.1
    • /
    • pp.82-89
    • /
    • 2000
  • The blood compatibilities of PU/PVA polymer blends with different mixing ratios were evaluated using various methods, such as fibrinogen adsorption, plasma recalcification time, platelet adhesion, whole blood clotting time, and complement activation. In addition, PVA on the surface of the polymer blends was crosslinked by glutaraldehyde to restrain the mobility of PVA molecules for characterizing the effect of PVA in the polymer blends on blood compatibility. The fibrinogen adsorption on the polymer blends decreased with the increase of PVA amount in the polymer blends. The plasma recalcification times of the polymer blends with 10-50 wt% PVA were longer than those of PU, PVA, and polymer blends with higher amount of PVA. The morphological changes and adhesion of platelets on the polymer blends with 30-50 wt% PVA were less than those on the other materials. The blood clotting times and complement activation on the polymer blends with 30-50 wt% PVA were reduced, compared to the other materials. On the other hand, the blood compatibility of the crosslinked polymer blends was relatively decreased, compared to the non-crosslinked ones. According to these experimental results, the blood compatibility of the polymer blends with 30-50 wt% PVA was better than that of the other materials and such a blood compatibility of the polymer blends might be related to the mobility of PVA molecules on the surface.

  • PDF

Temperature Dependence on the Binding of the Homologs of Methyl Orange by Crosslinked Poly(4-vinylpyridine). 6. Effect of Crosslinking Agent (가교폴리 (4-비닐피리딘) 과 메틸오렌지동족체와의 결합에 대한 온도의 존성. 6. 가교제의 영향)

  • Lee, Suck-Kee;Park, Nam-Kyu;Kim, Woo-Sik
    • Applied Chemistry for Engineering
    • /
    • v.1 no.2
    • /
    • pp.182-189
    • /
    • 1990
  • Various crosslinked poly(4-vinylpyridines) having different degrees of crosslinking were prepared by radical copolymerizations of 4-vinylpyridine with N, N'-2, 6-pyridinebisacrylamide as a crosslinker. The abilities of these crosslinked polymers to bind methyl orange and butyl orange were investigated at various temperatures in a buffer solution of pH 7. The first binding constants were evaluated from the equilibrium binding amounts. The first binding constants against the temperatures showed bell-shaped curves. Also, the first binding constants against the degree of crosslinking showed bell-shaped curves. When the temperature and the degree of crosslinking of maximum binding in the curves of these binding systems were compared with those of previous systems containing crosslinked poly(4-vinylpyridines) prepared by using N, N'-methylenebisacrylamide, N, N'-tetramethy-lenebisacryamide and divinylbenzene as crosslinkers, respectively, they were varied with the crosslinked poly(4-vinyl pyridines) containing different crosslinkers. These results were discussed in terms of the properties of the crosslinkers.

  • PDF

Molecular Structure and Tensile Properties Change of Crosslinked Polyethylene Pipes during Oxidative Degradation Process (산화열화과정 중 가교폴리에틸렌 파이프의 분자구조 및 인장 특성 변화)

  • Park, Sung-Gyu;Kim, Dae-Su
    • Polymer(Korea)
    • /
    • v.33 no.6
    • /
    • pp.520-524
    • /
    • 2009
  • The effects of oxidative degradation on the performance of crosslinked polyethylene pipes were analyzed by the investigation of tensile properties and chemical structure change of the pipes during oxidative degradation. Annealing at high temperatures or UV irradiation method was used to induce the oxidative degradation of the crosslinked polyethylene pipes and the effects of the die temperature on the oxidative degradation of the pipes were also investigated. The tensile properties and chemical structure change of the pipes were investigated by universal testing machine and FT-IR, respectively. With the progress of thermo-oxidative degradation the tensile strength of the pipes slowly decreased but the elongation at break rapidly decreased, and the chemical structure of the pipes also changed considerably because of the introduced oxygen molecules. These results would be useful in estimating the performance deterioration of the crosslinked polyethylene pipes due to the oxidative degradation during production and storage.

A Semi-Interpenetrating Network for Temperature-Sensitive Polymer System

  • Yuk, Soon-Hong;Cho, Sun-Hang
    • Macromolecular Research
    • /
    • v.8 no.2
    • /
    • pp.89-94
    • /
    • 2000
  • A semi-interpenetrating network (IPN) was prepared for a temperature-sensitive polymer system composed of sodium alginate and poly (N, N-dimethylaminoethyl methacrylate (DMAEMA)-co-ethyl acrylamide (EAAm)). The role of sodium alginate is to provide crosslinked network and that of poly(DMAEMA-co-EAAm) is to provide temperature responsiveness to the polymer system. Semi-IPN gel shows temperature-induced swelling transition at the same temperature of the lower critical solution temperature of poly(DMAEMA-co-EAAm) and its swelling kinetics is manipulated by the control of crosslinking densitv.

  • PDF