• 제목/요약/키워드: crosshead speed

검색결과 183건 처리시간 0.02초

식각된 비귀금속합금과 법랑질을 복합레진계 시멘트로 접착시킨 경우의 접착인장강도에 관한 연구 (A STUDY ON THE TENSILE BOND STRENGTH OF ETCHED-METAL RESIN-BONDED RETAINERS)

  • 박헌석;이선형;양재호;장완식
    • 대한치과보철학회지
    • /
    • 제24권1호
    • /
    • pp.85-90
    • /
    • 1986
  • The purpose of this study was to compare the tensile bond strength of Comspan and Panavia as a luting materials between electrochemically etched Ni-Cr-Be alloy castings and acid etchea human tooth enamel. Tensile bond strength was evaluated using an Instron testing machine at a crosshead speed of 2mm/min. The following conclusions can be drawn frfm this study ; 1. The tensile bond strength of etched-metal resin-bonded specimen was $179.0{\pm}42.5kg/cm^2$ in case of Comspan and $169.6{\pm}41.4kg/cm^2$ in case of Panavia. 2. The tensile bond strength was not significantly different between Comspan, using with bonding agent, and Panavia, using without bonding agent.

  • PDF

치과 캐드캠 시스템에서 사용되는 고분자 수복재료들의 표면특성과 접착양상 (Surface characteristics and bonding performance of polymer restorative materials for dental CAD/CAM systems)

  • 김재홍;김기백
    • 대한치과기공학회지
    • /
    • 제41권3호
    • /
    • pp.203-209
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the mechanical properties of polymer prosthetic and restorative materials for dental CAD/CAM using two test method; surface characteristics and shear bond strength. Methods: Commercialized CAD/CAM polymer blanks were investigated; One kinds of PMMA, and one PEKK blanks. A total of 20 PMMA and PEKK specimens were prepared, and each group was divided into 10 specimens. Average surface roughness was observed under surface profilometer. The contact angle was measured with a surface electrooptics. The bond strength was evaluated by a universal testing machine at a crosshead speed of 5mm/min. The data were statistically analyzed using independent t-test and Fisher's exact test(P<0.05). Results: The PMMA and PEKK group showed a significant difference in the shear bond strength with the composite resin(P<0.05). The surface roughness of the PEKK group was higher than that of the PMMA group. The fracture mode were observed in PEKK groups with 50% showing adhesive remnant index score. Conclusion: PEEK is used as substructure material and composite veneering material is applied. PEKK resins will contribute to the development of successful products that will provide structural and aesthetic satisfaction.

광경화성 3D 프린팅 레진의 출력각도에 따른 굽힘 특성과 신뢰성 평가 (Evaluation of flexural properties and reliability with photo-curing 3D printing resin according to the printing orientations)

  • 임용운;송두빈;황성식;김사학;한만소
    • 대한치과기공학회지
    • /
    • 제43권1호
    • /
    • pp.13-18
    • /
    • 2021
  • Purpose: This study aimed to compare the flexural properties and perform the Weibull analysis of photo-curing three-dimensional (3D) printing resin. Methods: Photo-curing temporary resin (3D polymer) was used as a printing resin. Specimens (65 × 10 × 3.3 ㎣) were prepared following the ISO 20975-1 guidelines and according to the different printing orientations using a digital light processing 3D printer (D2 120; Dentium). The flexural strength (FS), flexural modulus, and work of fracture (WOF) were measured using a universal testing machine (Instron 3344; Instron) at a crosshead speed of 5 mm/min. Results: In this study, the 0° orientation exhibited higher FS and WOF than the 45° orientation. Significant differences were found among the printing orientations (p<0.05). Specimens printed at the 0° orientation were the most accurate. In the Weibull analysis, 0° showed the greatest Weibull modulus (m), which represents a higher reliability. Conclusion: 3D printing should be selected and used by considering flexural properties, size accuracy, and reliability.

샌드블라스팅 처리와 라이너가 지르코니아와 전장도재의 전단결합 강도에 미치는 영향 (Effect of sandblasting and liner on shear bond strength of veneering ceramic to zirconia)

  • 김기백;김재홍
    • 대한치과기공학회지
    • /
    • 제43권1호
    • /
    • pp.6-12
    • /
    • 2021
  • Purpose: This study aimed to compare the shear bond strength between zirconia cores and veneer ceramics as per the sand blasting and liner treatments. Methods: The following 4 groups of zirconia-veneering ceramic specimens were prepared: (1) Group I, untreated; (2) Group II, with 110 ㎛ aluminium oxide (Al2O3) sandblasting; (3) Group III, with liner (IPS e.max ZirLiner; Ivoclar Vivadent); and (4) Group IV, with 110 ㎛ Al2O3 sand blasting and liner. Surface roughness was measured for all the prepared specimens, and the surface morphology was observed using a scanning electron microscope. All the samples (n=40) were fixed with measuring jigs, and shear bond strengths were obtained using a universal testing machine with a crosshead speed of 0.5 mm/min. The shear bond strength data were analyzed using one-way analysis of variance and t-test. The post hoc comparison was performed using the Tukey's test (α=0.05). Results: A significant difference in the surface roughness was observed between the specimens of groups I and II (p<0.05). Surface treatment with liner and sandblasting showed higher shear bond strength between zirconia core and veneering ceramic (p<0.05). Conclusion: The sand blasting and liner treatment increased the shear bond strength between zirconia core and veneering ceramic.

Effect of dentin surface roughness on the shear bond strength of resin bonded restorations

  • Koodaryan, Roodabeh;Hafezeqoran, Ali;Poursoltan, Sajjad
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.224-228
    • /
    • 2016
  • PURPOSE. This study aimed to investigate whether dentin surface preparation with diamond rotary instruments of different grit sizes affects the shear bond strength of resin-bonded restorations. MATERIALS AND METHODS. The buccal enamel of 60 maxillary central incisors was removed with a low speed diamond saw and wet ground with silicon carbide papers. The polished surfaces of the teeth were prepared with four groups of rotary diamond burs with super-coarse (SC), coarse (C), medium (M), and fine (F) grit sizes. Following surface preparation, 60 restorations were casted with nickel-chromium alloy and bonded with Panavia cement. To assess the shear bond strength, the samples were mounted on a universal testing machine and an axial load was applied along the cement-restoration interface at the crosshead speed of 0.5 mm/min. The acquired data was analyzed with one way ANOVA and Tukey post hoc test (${\alpha}=.05$). RESULTS. The $mean{\pm}SD$ shear bond strengths (in MPa) of the study groups were $17.75{\pm}1.41$ for SC, $13.82{\pm}1.13$ for C, $10.40{\pm}1.45$ for M, and $7.13{\pm}1.18$ for F. Statistical analysis revealed the significant difference among the study groups such that the value for group SC was significantly higher than that for group F (P<.001). CONCLUSION. Dentin surface roughness created by diamond burs of different grit sizes considerably influences the shear bond strength of resin bonded restorations.

치과용 아말감의 파절에 관한 연구 (A STUDY ON THE FRACTURE OF DENTAL AMALGAM)

  • 허현도;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제9권1호
    • /
    • pp.101-106
    • /
    • 1983
  • It was the purpose of this study to investigate the fracture mode of dental amalgam by observing the crack propagation, and to relate this to the microstructure of the amalgam. Caulk 20th Century Regular, Caulk Spherical, Dispersalloy, and Tytin amalgam alloys were used for this study. After each amalgam alloy and Hg measured exactly by the balance was triturated by the mechanical amalgamator (Capmaster, S.S. White), the triturated mass was inserted into the cylindrical metal mold which was 4 mm in diameter and 12 mm in height and was pressed by the Instron Universal Testing Machine at the speed of 1mm/min with 120Kg. The specimen removed from the mold was stored in the room temperature for a week. This specimen was polished with the emery papers from #100 to #200 and finally on the polishing cloth with 0.06${\mu}Al_2O_3$ powder suspended in water. The specimen was placed on the Instron testing machine in the method similar to the diametral tensile test and loaded at the crosshead speed of 0.05mm/min. The load was stopped short of fracture. The cracks on the polished surface of specimen was examined with scanning electron microscope (JSM-35) and analyzed by EPMA (Electron probe microanalyzer). The following results were obtained. 1. In low copper lathe-cut amalgam, the crack went through the voids and ${\gamma}_2$ phase, through the ${\gamma}_1$ phase around the ${\gamma}$ particles. 2. In low copper spherical amalgam, it was observed that the crack passed through the ${\gamma}_2$ and ${\gamma}_1$ phase, and through the boundary between the ${\gamma}_1$ and ${\gamma}$ phase. 3. In high copper dispersant (Dispersalloy) amalgam, the crack was found to propagate at the interface between the ${\gamma}_1$ matrix and reaction ring around the dispersant (Ag-Cu) particles, and to pass through the Ag-Sn particles. 4. In high copper single composition (Tytin) amalgam, the crack went through the ${\gamma}_1$ matrix between ${\eta}$ crystals, and through the unreacted alloy particle (core).

  • PDF

2단계 자가 산부식 접착제와 결합된 광중합과 화학중합 복합레진의 법랑질 접착 (ENAMEL ADHESION OF LIGHT-AND CHEMICAL-CURED COMPOSITES COUPLED BY TWO STEP SELF-ETCH ADHESIVES)

  • 한세희;김은성;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제32권3호
    • /
    • pp.169-179
    • /
    • 2007
  • 이 연구의 목적은 2단계 자가산부식 접착제를 이용하여 법랑질에 대한 광중합과 화학중합 복합레진의 결합강도 차이를 비교하고, 또한 현미경적 인 관찰을 통하여 2단계 자가 산부식 접착제가 법랑질에서 화학중합 복합레진과 비적합성을 나타내는가를 알아보기 위해 시행하였다. 미세전단 결합강도를 측정하기 위하여 Isomet Low Speed Saw를 이용하여 발거한 대구치를 근, 원심 방향으로 1 mm두께가 되도록 절단하여 여러 개의 절편을 만들었다. 치아의 절편들을4개의 군으로 분류한 후, 사용된 접착제에 따라 SE Bond 군, AdheSE 군, Tyrian 군 Contax 군으로 분류하였다. 각 군의 접착제를 각 절편의 법랑질 표면에 적용한 후, Tygon tube를 이용하여 광중합형 복합레진 (Filtek Z250) 또는 화학중합 복합레진 (Luxacore Smartmix Dual)을 접착하였다. 실온의 증류수에 24시간 동안 보관한 후, universal testing machine을 이용하여 각 시편의 복합레진과 법랑질의 접착계면이 파절될 때까지 분당 1 mm의 crosshead speed를 가하여 미세전단 결합강도를 측정하였다. 각 군의 미세전단 결합강도치에 대한 유의성 검증은 two-way ANOVA와 Tukey HSD검정 및 독립표본 t 검정을 이용하여 p = 0.05 유의수준에서 분석하였다. 주사전자 현미경 관찰을 위해 발거한 대구치의 협면이나 설면의 법랑질 일부를 Isomet Low Speed Saw로 절단한 후 각 군의 접착제와 광중합 복합레진 또는 화학중합 복합레진을 축조하여 각 군당 2개의 시편을 제작하였다. 주사전자 현미경 하에서 법랑질과 접착제 및 복합레진 계면을 관찰하여 다음과 같은 결과를 얻었다. 1. 광중합과 화학중합 복합레진 모두에서 SE Bond 군의 법랑질에 대한 미세전단 결합 강도는 다른 3개의 군보다 통계학적으로 높게 나타났다 (p < 0.05). 2. 광중합과 화학중합 복합레진 모두에서 AdheSE 군, Tyrian 군 Contax군의 법랑질에 대한 미세 전단 결합 강도는 통계학적으로 유의한 차이를 나타내지 않았다. 3. 동일한 접착제를 사용한 경우, 모든 군에서 법랑질에 대한 광중합 복합레진의 미세전단 결합강도는 화학중합 복합레진보다 통계학적으로 높게 나타났다 (p < 0.05). 4. 모든 접착제와 법랑질 계면은 긴밀한 접합을 나타내어 화학중합 복합레진과 접착제 간에 비적합성이 나타나지 않았다.

Pull-out bond strength of a self-adhesive resin cement to NaOCl-treated root dentin: effect of antioxidizing agents

  • Khoroushi, Maryam;Kachuei, Marzieh
    • Restorative Dentistry and Endodontics
    • /
    • 제39권2호
    • /
    • pp.95-103
    • /
    • 2014
  • Objectives: This study evaluated the effect of three antioxidizing agents on pullout bond strengths of dentin treated with sodium hypochlorite. Materials and Methods: Root canals of 75 single-rooted human teeth were prepared. Fifteen teeth were irrigated with normal saline for a negative control group, and the remaining 60 teeth (groups 2 - 5) with 2.5% NaOCl. The teeth in group 2 served as a positive control. Prior to post cementation, the root canals in groups 3 - 5 were irrigated with three antioxidizing agents including 10% rosmarinic acid (RA, Baridge essence), 10% hesperidin (HPN, Sigma), and 10% sodium ascorbate hydrogel (SA, AppliChem). Seventy-five spreaders (#55, taper .02, Produits Dentaires S.A) were coated with silica and silanized with the Rocatec system and ceramic bond. All the prepared spreaders were cemented with a self-adhesive resin cement (Bifix SE, Voco Gmbh) in the prepared canals. After storage in distilled water (24 h/$37^{\circ}C$), the spreaders were pulled out in a universal testing machine at a crosshead speed of 1.0 mm/min. Pull-out strength values were analyzed by one-way ANOVA and Tukey's HSD test (${\alpha}$ = 0.05). Results: There were significant differences between study groups (p = 0.016). The highest pullout strength was related to the SA group. The lowest strength was obtained in the positive control group. Conclusions: Irrigation with NaOCl during canal preparation decreased bond strength of resin cement to root dentin. Amongst the antioxidants tested, SA had superior results in reversing the diminishing effect of NaOCl irrigation on the bond strength to root dentin.

Effect of water storage on flexural strength of silorane and methacrylate-based composite resins

  • Panahandeh, Narges;Torabzadeh, Hassan;Naderi, Hani;Sheikh-Al-Eslamian, Seyedeh Mahsa
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.309-315
    • /
    • 2017
  • Objectives: This study assessed the effect of water storage on the flexural strength (FS) of low shrinkage composites. Materials and Methods: A total of 165 bar-shaped specimens ($2{\times}2{\times}25mm$) were fabricated of 2 low shrinkage composites (Filtek P90 [3M ESPE], GC Kalore [GC International]) and a conventional methacrylate-based composite (Filtek Z250 [3M ESPE]). The specimens were subjected to 3-point bending test at 6 time intervals, namely: immediately after curing, at 24 hours, 1 week, 1 month, 6 months, and 1 year following storage in wet and dry conditions. The FS of the specimens were measured by applying compressive load at a crosshead speed of 1.0 mm/min. Data was analyzed using 3-way analysis of variance (ANOVA) and Tukey's test. Results: Three-way ANOVA revealed significant interactions between time, type of composite, and storage condition (p = 0.001). Tukey's multiple comparison test revealed significant reductions in FS of all composites after 6 months and 1 year of storage in distilled water compared to dry condition. Conclusions: Filtek P90 showed the highest and GC Kalore showed the lowest FS after 1 year storage in distilled water. The immediate high strength of Filtek Z250 significantly decreased at 1 year and its final value was lower than that of Filtek P90.

The effect of resin cement type and cleaning method on the shear bond strength of resin cements for recementing restorations

  • Koodaryan, Roodabeh;Hafezeqoran, Ali;Maleki, Amin Khakpour
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권2호
    • /
    • pp.110-117
    • /
    • 2017
  • PURPOSE. This laboratory study assessed the effect of different dentin cleaning procedures on shear bond strength of resin cements for recementing prosthesis. MATERIALS AND METHODS. A $4{\times}4$ flat surface was prepared on the labial surface of 52 maxillary central incisors. Metal frames ($4{\times}4{\times}1.5mm$) were cast with nickel-chromium alloy. All specimens were randomly divided into 2 groups to be cemented with either Panavia F2.0 (P) or RelyX Ultimate (U) cement. The initial shear bond strength was recorded by Universal Testing Machine at a crosshead speed of 0.5 mm/min. Debonded specimens were randomly allocated into 2 subgroups (n = 13) according to the dentin cleaning procedures for recementation. The residual cement on bonded dentin surfaces was eliminated with either pumice slurry (p) or tungsten carbide bur (c). The restorations were rebonded with the same cement and were subjected to shear test. Data failed the normality test (P < .05), thus were analyzed with Mann Whitney U-test, Wilcoxon signed rank test, and two-way ANOVA after logarithmic transformation (${\alpha}=.05$). RESULTS. The initial shear bond strength of group P was significantly higher than group U (P = .001). Pc and Uc groups presented higher bond strength after recementation compared to the initial bond strength. However, it was significant only in Pc group (P = .034). CONCLUSION. The specimens recemented with Panavia F2.0 provided higher bond strength than RelyX Ultimate cement. Moreover, a tungsten carbide bur was a more efficient method in removing the residual resin cement and increased the bond strength of Panavia F2.0 cement after recementation.