• Title/Summary/Keyword: crossed-condition

Search Result 53, Processing Time 0.03 seconds

Implant-assisted Removable Prosthetic Rehabilitation of a Patient with Crossed Occlusion

  • Oh, Hyun-Su;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • Journal of Korean Dental Science
    • /
    • v.14 no.1
    • /
    • pp.32-39
    • /
    • 2021
  • 'Crossed occlusion' is the condition in which occlusal intercuspation is lost when several teeth on upper and lower jaw remain. This report describes a clinical case in which a patient had two upper-left posterior teeth and two lower-right posterior teeth; typically known as left-right crossed occlusion. Considering the patient's general condition and financial situation, the treatment plan included placement of two implants on each jaw against the remaining teeth using surgical guide. To find out the ideal position of implants, digital diagnostic wax-up was preceded by superimposing the cast and cone beam computed tomography image, which was aided with radiographic stents. The consequent surveyed implant bridge provided stable vertical stop for fabrication of the implant assisted removable partial dentures. The patient was satisfied with the functionality and esthetics of definitive prosthesis.

GALOIS CORRESPONDENCES FOR SUBFACTORS RELATED TO NORMAL SUBGROUPS

  • Lee, Jung-Rye
    • Communications of the Korean Mathematical Society
    • /
    • v.17 no.2
    • /
    • pp.253-260
    • /
    • 2002
  • For an outer action $\alpha$ of a finite group G on a factor M, it was proved that H is a, normal subgroup of G if and only if there exists a finite group F and an outer action $\beta$ of F on the crossed product algebra M $\times$$_{\alpha}$ G = (M $\times$$_{\alpha}$ F. We generalize this to infinite group actions. For an outer action $\alpha$ of a discrete group, we obtain a Galois correspondence for crossed product algebras related to normal subgroups. When $\alpha$ satisfies a certain condition, we also obtain a Galois correspondence for fixed point algebras. Furthermore, for a minimal action $\alpha$ of a compact group G and a closed normal subgroup H, we prove $M^{G}$ = ( $M^{H}$)$^{{beta}(G/H)}$for a minimal action $\beta$ of G/H on $M^{H}$.f G/H on $M^{H}$.TEX> H/.

Topologically free actions and purely infinite $C^{*}$-crossed products

  • Jeong, Ja-A
    • Bulletin of the Korean Mathematical Society
    • /
    • v.31 no.2
    • /
    • pp.167-172
    • /
    • 1994
  • For a given $C^{*}$-dynamical system (A, G, .alpha.) with a G-simple $C^{*}$-algebra A (that is A has no proper .alpha.-invariant ideal) many authors have studied the simplicity of a $C^{*}$-crossed product A $x_{\alpha{r}}$ G. In [1] topological freeness of an action is shown to guarantee the simplicity of the reduced $C^{*}$-crossed product A $x_{\alpha{r}}$ G when A is G-simple. In this paper we investigate the pure infiniteness of a simple $C^{*}$-crossed product A $x_{\alpha}$ G of a purely infinite simple $C^{*}$-algebra A and a topologically free action .alpha. of a finite group G, and find a sufficient condition in terms of the action on the spectrum of the multiplier algebra M(A) of A. Showing this we also prove that some extension of a topologically free action is still topologically free.

  • PDF

Design of Self Magnetization MsS Sensor Using Crossed Coils (Crossed-Coils를 이용한 자기자화 MsS센서의 설계)

  • Kim, Yi-Gon;Park, Kyung-Jo;Moon, Hong-Sik;Kim, Jae-Hyun;Ahn, Hyun-Jin;Kang, Woo-Seok;Oh, Un-Kyung
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2008.04a
    • /
    • pp.205-208
    • /
    • 2008
  • This paper propose a advanced technique for exciting and receiving the guided torsional wave to detect flaws in pipe systems. There are some difficulties in selecting and exciting of modes by using the nickel strip attached on pipe systems, such as qualification of residual magnetic field and multi-exciting of the unwanted modes etc. In order to there difficulties we propose the new sensor, so called Crossed-coils sensor. We will prove that it is possible to select the modes to be excited and to find a optimal excitation condition for torsional mode by using the proposed sensor.

  • PDF

Design of Self Magnetization MsS Sensor Using Crossed Coils (Crossed-Coils를 이용한 자기자화 MsS센서의 설계)

  • Kim, Yi-Gon;Park, Kyung-Jo;Moon, Hong-Sik;Kim, Jae-Hyun;Ahn, Hyun-Jin;Kang, Woo-Seok;Oh, Un-Kyung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.6
    • /
    • pp.856-862
    • /
    • 2008
  • This paper propose a advanced technique for exciting and receiving the guided torsional wave to detect flaws in pipe systems. There are some difficulties in selecting and exciting of modes by using the nickel strip attached on pipe systems, such as qualification of residual magnetic field and multi-exciting of the unwanted modes etc. In order to there difficulties we propose the new sensor, so called Crossed-coils sensor. We will prove that it is possible to select the modes to be excited and to find a optimal excitation condition for torsional mode by using the proposed sensor.

Crossed Renal Ectopia and Aorto-Occlusive Disease: A Management Strategy

  • Ng, Eugene;Campbell, Ian;Choong, Andrew MTL;Dunglison, Nigel;Aziz, Maged
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.371-374
    • /
    • 2015
  • We present a rare case of a patient with aortoiliac occlusive disease on the background of type A crossed renal ectopia, for whom open surgical intervention was required. Aortic exposure in patients with concomitant crossed renal ectopia can present technical challenges to the vascular surgeon. The knowledge of variations in the ectopic renal blood supply is of paramount importance when performing surgery to treat this condition and affects the choice of surgical exposure. We present and discuss the operative details of our patient and outline an approach to this subset of patients.

Rehabilitation of a patient with crossed occlusion using mandibular implant-supported fixed and maxillary Kennedy class IV removable dental prostheses: A case report (엇갈린 교합 환자의 임플란트 지지 고정성 보철물과 Kennedy class IV 가철성 국소의치를 이용한 수복 증례)

  • Kang, Seok-Hyung;Han, Jung-Suk;Kim, Sung-Hun;Yoon, Hyung-In;Yeo, In-Sung
    • The Journal of the Korean dental association
    • /
    • v.55 no.12
    • /
    • pp.842-849
    • /
    • 2017
  • The term, 'crossed occlusion' implies clinical situation in which the residual teeth in one arch have no contact with those in the antagonistic arch, resulting in the collapse of occlusal vertical dimension. The treatment goal of this pathologic condition is restoration of the collapsed vertical dimension and stabilization of abnormal mandibular position. Previously, konus removable prostheses or tooth supported overdentures were suggested to solve crossed occlusion. Nowadays, dental implants have been used for definitive support to solve this problem. In this case report, a 65 years old female patient had a crossed occlusion, in which the maxillary posterior residual teeth and mandibular anterior residual teeth cross. Interim removable and fixed dental prostheses were used to confirm the proper vertical and horizontal jaw relation. After that, the mandibular posterior edentulous region was restored with implant-supported fixed dental prostheses. Computer tomography guided implant surgery was performed according to the concept of the restoration-driven implant placement. The maxillary anterior edentulous region was restored with Kennedy class IV removable prosthesis, considering the patient's economic status. The patient's jaw position and prostheses have been well maintained at the follow-up after 6 months of definitive restoration. The antero-posterior crossed occlusion problems appeared to be effectively solved with the combination of removable in one arch and implant-supported fixed prostheses in the other.

  • PDF

Behavior of the Ground in Obliquely Crossed area Due to Tunnel Excavation Under the Existing Tunnel (기존터널에 근접하여 경사로 교차되는 하부터널굴착에 따른 교차부지반의 거동)

  • Kim, Dong-Gab;Lee, Sang-Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.4
    • /
    • pp.285-294
    • /
    • 2005
  • The behaviors of the ground in crossed zone and the existing upper tunnel in shallow cover due to the excavation of new lower tunnel crossed to that was studied. Model test was performed in the large scale test pit, the size was '$4.0m(width){\times}3.8m(height){\times}4.1m(length)$'. Test ground was constructed uniformly by sand in middle density and test with the crossed angle of $56^{\circ}$ (obliquely) were performed. The numerical analysis was performed on equal condition with model test. Results of the study by model test and numerical analysis show that earth pressure and settlement of the ground in crossed zone were redistributed due to the longitudinal arching effect by the excavation of lower tunnel. Model test shows that upper tunnel blocks stress flow due to the longitudinal arching effect by excavation of lower tunnel.

  • PDF

Large-area Uniform Deposition of Amorphous Hydrogenated Carbon Films using a Plasma CVD Method (플라즈마 CVD 법을 이용한 대면적 균일한 비정질 탄소 막 증착)

  • Yun, Sang-Min;Yang, Sung-Chae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.5
    • /
    • pp.411-414
    • /
    • 2009
  • It has been investigated for the film uniformity and deposition rate of a-C:H films on glass substrate and polymeric materials in the presence of the modulated crossed magnetic field. We used Plasma CVD, i.e, using a crossed electromagnetic field, for uniform depositing thin film. The optimum discharge condition has been discussed for the gas pressure, the magnetic flux density and the distance between substrate and electrodes, As a result, it is found that the optimum discharge conditions are $CH_4$ concentration $CH_4$=10 %, modulated magnetic flux density B=48 Gauss, pressure P=100 mTorr, discharge power supply voltage V=l kV under these experimental conditions. By using these experimental condition, it is possible to prepare the most uniform film extends over about 160 mm of the film width. In this study, we deposited a-C:H thin film on glass substrate, and have a plan that using this condition, study depositing a-C:H thin film on polymeric substrate in next studies.

Full mouth rehabilitation of the patient with crossed occlusion using removable partial denture restoration: A case report (엇갈린 교합 환자에서의 가철성 보철을 이용한 전악구강회복 증례)

  • Choi, Yu-Ra;Kang, Jeong-Kyung;Kim, Na-Hong;Chang, Hee-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.38-45
    • /
    • 2017
  • In removable partial denture with crossed occlusion, it is difficult to meet the satisfaction of patient due to variable movement of denture and unfavorable stability under loading. In a case with few unilaterally teeth remaining, additional treatments such as implantation or residual root are required to assure bilaterally stable support. However, due to the medical condition of the patient with hypertension, angina and old age etc., removable partial denture was planned as treatment in this case. Proper diagnosis, accurate analysis and full understanding of the adaptation for neuromuscular system are necessary to recover the vertical dimension of patient from a decreased vertical dimension due to crossed occlusion.