• 제목/요약/키워드: cross-linked polyethylene (XLPE)

검색결과 47건 처리시간 0.029초

내부 보이드 결함에서 발생하는 전기트리의 부분방전 특성 (PD Characteristic of Electrical Tree Generated by Inside Void Defect)

  • 박성희;정해은;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.334-335
    • /
    • 2006
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is 7*5*7 $mm^3$. Distance of needle and plane is 2 mm. Voltages applied for acceleration test are 12 kV to 15 kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system (Biddle instrument). The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

전기트리 발생/열화진행과 PD와의 관계분석 (Analysis relationship with PD characteristics and occurrence of electrical treeing)

  • 정해은;박성희;임기조;강성화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1476-1477
    • /
    • 2006
  • Solid insulation exposed to voltage is degraded and by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE(cross-linked polyethylene). And the size of the specimen is 7*5*7 $mm^3$. Distance of needle and plane is 2mm. Voltage applied for acceleration test are 12kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system(Biddle instrument). Their results of PD distribution show good present and are good discriminating skill.

  • PDF

내부결함에서 나타나는 전기트리의 부분방전 특성 (PD Characteristic of Electrical Tree Generated by Internal Defects)

  • 김병철;윤재훈;박성희;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1387-1388
    • /
    • 2007
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experiment, specimens of electrical tree models were made by three types of XLPE (cross-linked polyethylene). And distribution characteristics of degraded stages are studied too. As a method of detecting and data process, discharge data was acquired from PD detecting system (Biddle instrument). And microscope and digital camera were used to observe the morphologies of the electrical tree to divide stages of the tree. The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

Defect Diagnosis of Cable Insulating Materials by Partial Discharge Statistical Analysis

  • Shin, Jong-Yeol;Park, Hee-Doo;Lee, Jong-Yong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권1호
    • /
    • pp.42-47
    • /
    • 2010
  • Polymer insulating materials such as cross linked polyethylene (XLPE) are employed in electric cables used for extra high voltage. These materials can degrade due to chemical, mechanical and electric stress, possibly caused by voids, the presence of extrinsic materials and protrusions. Therefore, this study measured discharge patterns, discharge phase angle, quantity and occurrence frequency as well as changes in XLPE under different temperatures and applied voltages. To quantitatively analyze the irregular partial discharge patterns measured, the discharge patterns were examined using a statistical program. A three layer sample was fabricated, wherein the upper and lower layers were composed of non-void XLPE, while the middle layer was composed of an air void and copper particles. After heating to room temperature and $50^{\circ}C$ and $80^{\circ}C$ in silicone oil, partial discharge characteristics were studied by increasing the voltage from the inception voltage to the breakdown voltage. Partial discharge statistical analysis showed that when the K-means clustering was carried out at 9 kV to determine the void discharge characteristics, the amount discharged at low temperatures was small but when the temperature was increased to $80^{\circ}C$, the discharge amount increased to be 5.7 times more than that at room temperature because electric charge injection became easier. An analysis of the kurtosis and the skewness confirmed that positive and negative polarity had counterclockwise and clockwise clustering distribution, respectively. When 5 kV was applied to copper particles, the K-means was conducted as the temperature changed from $50^{\circ}C$ to $80^{\circ}C$. The amount of charge at a positive polarity increased 20.3% and the amount of charge at a negative polarity increased 54.9%. The clustering distribution of a positive polarity and negative polarity showed a straight line in the kurtosis and skewness analyses.

ANFIS 분류기법을 이용한 부분방전원의 분류 (PD classification by using ANFIS method)

  • 박성희;윤재훈;김병철;임기조;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.467-467
    • /
    • 2007
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is $7^*5^*7mm^3$. Distance between needle and plane is 2 mm. Voltages applied to acceleration test are ranged 12 to 15 kV. And distribution characteristic of degraded stage is studied too. By PD detecting and data processing, discharge data was acquired from PD detecting system (Biddle instrument). The system presents statistical distribution of phase resolved. Moreover, the processing time of electrical tree is recorded to know the speed of degradation according to voltage. Finally, it's used PD classification by ANFIS method.

  • PDF

전기트리시 발생하는 부분방전원 분류기법 비교 분석 (Comparing and Analysis for Classification of PD Source Generated by Electrical Tree)

  • 윤재훈;김병철;강성화;정수현;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.464-465
    • /
    • 2007
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is $7*5*7\;mm^3$. Distance of needle and plane is 2 mm. Voltages applied for acceleration test are 12 kV to 15 kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system (Biddle instrument). The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

고전압 전력케이블 절연체 응용을 위한 임팩트 폴리프로필렌 기반 3성분계 블렌드의 기계적 및 전기적 특성에 대한 연구 (Mechanical and Electrical Properties of Impact Polypropylene Ternary Blends for High-Voltage Power Cable Insulation Applications)

  • 이성환;김도균;홍신기;한진아;한세원;이대호;유승건
    • Composites Research
    • /
    • 제35권3호
    • /
    • pp.127-133
    • /
    • 2022
  • 폴리프로필렌은 가교폴리에틸렌을 대체할 수 있는 차세대 고전압 전력케이블 절연체로써 큰 주목을 받고 있다. 하지만, 폴리프로필렌은 탄성률이 크고 충격에 취약하여 단독으로 절연체로 사용될 수 없고, 중합 단계에서 고무상이 혼재된 공중합체 형태로 주로 활용된다. 본 논문에서는 내충격성 폴리프로필렌, 폴리올레핀 탄성체, 그리고 프로필렌-에틸렌 랜덤공중합체의 용융 혼합을 통해 연성의 폴리프로필렌계 블렌드를 제조하였다. 폴리프로필렌 기재를 유지하면서도 다량의 탄성체 상들을 지니는 적정 비율의 3성분계 블렌드를 개발하였고, 탄성체 상들의 도입에 의해 폴리프로필렌의 탄성률을 감소시킬 수 있을 뿐만 아니라, 25도 및 -40도에서의 충격강도 및 연신율을 크게 증가시킬 수 있었다. 또한, 동적기계분석을 통해 가교폴리에틸렌이 기계적 물성을 손실하는 100도 이상의 온도에서도 3성분계 블렌드는 고체 형태를 유지할 수 있는 범위의 저장탄성률을 나타내었다. 뿐만 아니라, 3성분계 블렌드는 30 kV/mm의 직류 전압 인가 하에서 공간전하를 효과적으로 억제시키는데 유리한 것으로 나타났다.