• Title/Summary/Keyword: cross sectional study

Search Result 5,100, Processing Time 0.042 seconds

The Correlation between Ultrasonographic Findings of Median Nerve and Clinical Scale and Electrodiagnotic Data in Carpal Tunnel Syndrome (수근관 증후군에서 임상양상척도 및 신경전기진단 결과와 정중신경 초음파 소견의 상관관계)

  • Lee, Gyu-Ho;Kim, Sei-Joo;Yoon, Joon-Shik;Park, Byung-Kyu;Cho, Jung-Mo;Jung, Jin-Seok
    • Annals of Clinical Neurophysiology
    • /
    • v.12 no.2
    • /
    • pp.55-60
    • /
    • 2010
  • Background: The aim of this study is to identify the correlation between ultrasonographic findings of median nerve and clinical scale and electrophysiologic data in carpal tunnel syndrome. Methods: Forty three patients (79 hands) with electrophysiologically confirmed carpal tunnel syndrome were evaluated. Clinical symptoms were examined by Historical-Objective (Hi-Ob) scale. Electrophysiologic data and Padua scale were used for severity of electrophysiology. In ultrasonographic study, cross sectional area and flattening ratio of median nerve were measured at distal wrist crease level (DWC), 1cm proximal to distal wrist crease level, and 1cm distal to distal wrist crease level. The correlation between Hi-Ob scale, electrophysiologic data and ultrasonography was measured with Spearman rank test. Results: The mean Hi-Ob scale was 2.4. Mean Padua scale was 4.0. In ultrasnonographic study, cross sectional area and flattening ratio were $0.112\;cm^2{\pm}0.025$ and $3.0{\pm}0.6$ at 1cm proximal to DWC level, $0.118{\pm}0.026\;cm^2$ and $2.9{\pm}0.4$ at DWC level, and $0.107{\pm}0.032\;cm^2$ and $3.0{\pm}0.4$ at 1 cm distal to DWC level. Hi-Ob scale was not correlated with cross sectional area and flattening ratio of median nerve. Hi-Ob scale was correlated with Padua scale positively (r=0.44) and correlated with amplitudes of CMAP and SNAP, negatively (r=-0.33; r=-0.30). Cross sectional area of median nerve was significantly correlated with Padua scale, amplitudes and latencies of CMAP and amplitudes of SNAP. Conclusions: Ultrasonographic findings of median nerve and electrodiagnostic data had statistically significant correlation. Consequently, ultrasonography could be an adjunctive method in diagnosis of carpal tunnel syndrome.

A Numerical Study of 3-D Flows in Spiral Tubes with Square Cross-Section (Spiral Tube 내에서의 3차원 유동 해석)

  • Hur Nahmkeon;Kim Seongwon
    • Journal of computational fluids engineering
    • /
    • v.4 no.1
    • /
    • pp.27-33
    • /
    • 1999
  • Spiral tube heat exchangers can find numerous applications in many engineering fields. Flow in spiral tubes is interest to engineers due to occurrence of secondary flow which enhances the cross-sectional mixing and the heat transfer rate. In the present study, an incompressible viscous 3-D flow in spiral tubes with rectangular cross-section of various torsion rate and Reynolds number is studied by using a finite volume method. It is shown that the axial velocity profile is affected by the secondary flow motion. Because there is some difference from correlation proposed by Hur et al., a lot of analysis and arrangement of experimental results are needed. This study showed the results of variation of hydrodynamic entry length for torsion and Re numbers.

  • PDF

Analysis of Internal Overpressure by Pipe Cross-Sectional Area Ratio and Filling Rate in the Hydraulic Test of Shipboard Tank (수압시험 시 관 단면적 비 및 충수 속도별 탱크 내부 과압 발생에 관한 해석)

  • Geun-Gon Kim;Tak-Kee Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.6
    • /
    • pp.460-472
    • /
    • 2023
  • This study was conducted based on the case of an accident (excessive deformation) that occurred during the hydraulic test of a shipboard tank manufactured in accordance with the design regulations. Over-pressure phenomenon was noted as the main cause of accidents in the process of testing tanks without physical damage, which can be found in external factors such as cross-sectional difference between inlet pipe and air pipe and higher water filling rate than the recommended one. The main goal of this paper is to establish a safe water filling rate according to the range of sectional area ratio(SAR) reduced below the regulations for each test situation. The simulation was conducted in accordance with the hydraulic test procedure specified in the Ship Safety Act, and the main situation was divided into two types: filling the tank with water and increasing the water head to the test pressure. The structural safety evaluation of the pressure generated inside the tank and the effect on the structure during the test was reviewed according to the SAR range. Based on the results, guidelines for the optimal filling rate applicable according to SAR during the hydraulic test were presented for the shipboard tanks used in this study.

Effects of Low Visual Acuity Simulations on Eye-Hand Coordination and Brainwaves in Healthy Adults

  • Woo, Hee-Soon;Song, Chiang-Soon
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.3
    • /
    • pp.296-303
    • /
    • 2022
  • Objective: In general, macular degeneration, cataracts and glaucoma generally cause visual injury in clinical settings. This study aimed to examine the effects of low visual acuity simulations on hand manual dexterity function and brainwaves in healthy young adults. Design: Cross-sectional study design Methods: This study was an observational, cross-sectional study. Seventy healthy young adults participated in this study. To evaluate the effects of low visual acuity simulations on hand function and brain waves, this study involved four different visual conditions including (1) normal vision, (2) simulated cataracts, (3) simulated glaucoma, and (4) simulated macular degeneration. The hand function was measured to use the Minnesota manual dexterity test (MMDT), and the brainwaves was also measured to use the electroencephalography. Results: In hand function, placing and turning performance on the MMDT in the normal visual condition was significantly different than that in the cataract and macular degeneration conditions (p<0.05), and the placing performance was significantly differred in the normal condition than that in the simulated glaucoma. However, turning was not significantly different in the normal condition than that in the simulated glaucoma. The alpha, beta, and gamma waves did not significantly differ among the four visual conditions (p>0.05). Conclusions: The results suggest that limited visual information negatively affects the ability to perform tasks requiring arm-hand dexterity and eye-hand coordination. However, the effectiveness of low visual acuity on the brainwaves should be further studied for rehabilitative evidence of visual impairment.

Difference of holding power of concrete weight used in shellfish shell fishery by its shape characteristics (패류껍질어업에서 사용 중인 멍의 형태적 특성에 따른 고정력의 차이)

  • LEE, Gun-Ho;CHO, Sam-Kwang;KIM, In-Ok;CHA, Bong-Jin;JUNG, Seong-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.54 no.1
    • /
    • pp.25-31
    • /
    • 2018
  • In this study, the differences of holding power according to the shape and weight distribution of concrete weight used in shellfish shell fishery were investigated through the experiments. To investigate the differences in shape, five bar-shaped concrete weights with the same length and different cross-sectional shapes were produced. The sectional shape of each weight was square, triangle, circle, small cross, and large cross (SQ, TR, CI, CR-S, CR-L). Ten rectangular parallelepiped weights with different bottom area and cross-sectional area were produced. To investigate the differences by the weight distribution, the holding power on the square model (SQ) with six 50 g weights at different positions was investigated. All the holding power was obtained by measuring the tensile force generated when the concrete weight was pulled at a constant speed on the sand. As a result, there were no differences in holding power between the ten rectangular weights. However, the experiment on weights with different cross-sectional shapes showed differences in holding power. The holding power was higher in the order of CR-L > CR-S > CI > TR > SQ. In the weight distribution test, the holding power was higher as the front side of the weight was heavier. Generally, the frictional force is the same even if the shape is different, when two objects have the same value in the weight and the roughness. On the other hand, it seems to have a large impact when the shape of the bottom is deformed in the course of pulling the object. Particularly, the larger the degree of protrusion like cruciform weights, the more the holding power increased while deeply digging the bottom. It is also likely that the holding power increases as the front weight increases.

Elimination of the effect of strain gradient from concrete compressive strength test results

  • Tabsh, Sami W.
    • Computers and Concrete
    • /
    • v.3 no.6
    • /
    • pp.375-388
    • /
    • 2006
  • Poor strength test results are sometimes not an indication of low concrete quality, but rather inferior testing quality. In a compression test, the strain distribution over the ends of the specimen is a critical factor for the test results. Non-uniform straining of a concrete specimen leads to locally different compressive stresses on the cross-section, and eventual premature breaking of the specimen. Its effect on a specimen can be quantified by comparing the compressive strength results of two specimens, one subjected to uniform strain and another to a specified strain gradient. This can be done with the help of a function that relates two parameters, the strain ratio and the test efficiency. Such a function depends on the concrete strength and cross-sectional shape of the specimen. In this study, theoretical relationships between the strain ratio and test efficiency are developed using a concrete stress-strain model. The results show that for the same strain ratio, the test efficiency is larger for normal strength concrete than for high strength concrete. Further, the effect of the strain gradient on the test result depends on the cross-sectional shape of the specimen. Implementation of the results is demonstrated with the aid of two examples.

Development of a Design System for a Cable Tray (케이블 트레이 설계시스템 개발)

  • Choi, Du-Soon;Choi, WooSeok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.4
    • /
    • pp.89-96
    • /
    • 2017
  • A cable tray is a structure made of metal or a non-combustible material that supports cables in the electrical wiring of buildings. Cable trays should be developed to meet the various requirements of the construction site. In this study, a design system was developed to calculate the maximum support load and the maximum deflection according to the cross-sectional shape of the cable tray. The cross-sections of cable trays were modeled by combining linear and arc elements, and cross-sectional characteristics such as the 2nd moment of area were calculated. The distributed load and the concentrated load were applied to the cable tray using the Euler beam theory, and then the deflection profiles and maximum stress were calculated. To verify the developed system, deflection distributions and maximum stresses for two types of cable trays were calculated and compared. The maximum deflection and maximum stress errors calculated from the developed system were found to be less than 4% compared with numerical analysis results.

A Study on Optimum design of Corrugated web girder using Eurocode (유로코드를 이용한 주름웨브보의 최적설계 연구)

  • Shon, Su-Deok;Yoo, Mi-Na;Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.4
    • /
    • pp.47-56
    • /
    • 2012
  • This paper describes the structural design and optimization of sinusoidally corrugated web girder by using EUROCODE (EN 1993-1-5). The optimum design methodology and characteristics of the optimal cross-section are discussed. We investigate a shear buckling and the concerned standards for corrugated web and explain the equations to obtain a critical stress according to buckling type. In order to perform optimization, we consider an objective function as minimum weight of the girder and use the constraint functions as slenderness ratio and stresses of flanges as well as corrugated web and deflection. Genetic Algorithm is adopted to search a global optimum solution for this mathematical model. For numerical example, the clamped girder under the concentrated load is considered, while the optimum cross-sectional area and design variables are analyzed. From the results of the adopted example, the optimum design program of the sinusoidally corrugated web girder is able to find the suitable solution which satisfied a condition subject to constraint functions. The optimum design shows the tendency to decrease the cross-sectional area with the yielding strength increase and increase the areas with load increase. Moreover, the corrugated web thickness shows a stable increase concerning the load.

One-Dimensional Beam Modeling of a Composite Rotor Blade (복합재 블레이드의 1차원 보 모델링)

  • Lee, Min-Woo;Bae, Jae-Sung;Lee, Soo-Yong;Lee, Seok-Joon;Jeon, Boo-Il
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.1
    • /
    • pp.7-12
    • /
    • 2008
  • The three-dimensional finite element modeling of a composite rotor blade is very hard and requires much computation effort. The efficient method to model a composite beam is necessary for the dynamic and aeroelastic analyses of rotor blades. In this study, the beam modeling method of a composite rotor blade is studied using VABS. The computer program, VABS (Variational Asymptotic Beam Section Analysis), uses the variational asymptotic method to split a 3-D nonlinear elasticity problem into 2-D cross-sectional analysis and 1-D nonlinear beam problem. The VABS can produce the sectional stiffness coefficients of composite rotor blades with various cross section and initial twist/curvatures, and recover the original 3-D distribution of displacement/strain/stress fields. The results of various cross section beams show that VABS gives us the accurate results comparared to commercial codes and does not need much computation effort. It can be concluded that VABS provides the efficient method to establish the FE model of a composite rotor blade.

  • PDF

Tightness Evaluation of Smart Sportswear Using 3D Virtual Clothing (3D 가상착의를 이용한 스마트 스포츠웨어의 밀착성 평가)

  • Soyoung Kim;Heeran Lee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.47 no.1
    • /
    • pp.123-136
    • /
    • 2023
  • To develop smart sportswear capable of measuring biometric data, we created a close-fitting pattern using two- and three-dimensional (2D and 3D, respectively) methods. After 3D virtual fitting, the tightness of each pattern was evaluated using image processing of contact points, mesh deviation, and cross-sectional shapes. In contact-point analysis, the 3D pattern showed high rates of contact with the body (84.6% and 93.1% for shirts and pants, respectively). Compared with the 2D pattern, the 3D pattern demonstrated closer contact at the lower chest, upper arm, and thigh regions, where electrocardiography and electromyography were primarily carried out. The overall average gap was also lower in the 3D pattern (5.27 and 4.66 mm in shirts and pants, respectively). In the underbust, waist, thigh circumference, and mid-thigh circumference, the cross-section distance between clothing and body was showed a statistically significant difference and evenly distributed in the 3D pattern, exhibiting more closeness. The tightness and fit of the 3D smart sportswear sensor pattern were successfully evaluated. We believe that this study is critical, as it facilitates the comparison of different patterns through visualization and digitization through 3D virtual fitting.