• Title/Summary/Keyword: cross sectional method

Search Result 1,324, Processing Time 0.035 seconds

Deformation Measurement of Polymer Scaffold Using Particle Image Analysis (입자 영상 해석을 이용한 고분자 지지체 변형 측정)

  • Kang, Min Je;Oh, Sang Hoon;Rhee, Kyehan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.1
    • /
    • pp.69-75
    • /
    • 2016
  • Polydimethylsiloxane (PDMS) is used as a scaffold for cell culture. Because both the stress and strain acting on the substrate and the hemodynamic environment are important for studying mechano-transduction of cellular function, the traction force of the surface of a substrate has been measured using fluorescence images of particle distribution. In this study, deformation of the cross-sectional plane of a PDMS block was measured by correlating particle image distributions to validate the particle image strain measurement technique. Deformation was induced by a cone indentor and a shearing parallel plate. Measured deformations from particle image distributions were in agreement with the results of a computational structure analysis using the finite-element method. This study demonstrates that the particle image correlation method facilitates measurement of deformation of a polymer scaffold in the cross-sectional plane.

Measurement of Cross-sectional Temperature Distribution in Micro-scale Gap Fluid Using LIF Technique in Combination with CLSM (LIF 및 CLSM을 결합한 미소 간극 내 유체의 단면 온도 분포 측정 기법)

  • Jeong, Dong-Woon;Lee, Sang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.834-841
    • /
    • 2006
  • In the present wort the Laser-induced Fluorescence (LIF) technique and Confocal Laser Scanning Microscopy (CLSM) have been combined to measure the temperature distribution across a micro-scale liquid layer as a direct and non-invasive method. Only the fluorescent light emitted from a very thin volume around a focal plane can be selectively detected, and it enables us to measure the liquid temperatures even at the close vicinity of the walls. As an experimental verification, a test section consists of two flat plates (for heating and cooling, respectively) separated by about 240 microns was made, and the methanol mixed with a temperature-sensitive dye, Rhodamine B, was filled in the gap between them. The measured temperature distribution across the gap showed good linearity, which is a typical characteristic of conduction heat transfer through a thin liquid layer. In result, the CLSM-LIF technique proposed in the present study was found to be a promising method to measure the local temperatures in the liquid flow field in microfluidic devices.

Welding Characteristics of Rapid Palatal Expander for Teeth Calibration using a Continuous Wave Nd:YAG Laser (연속파 Nd:YAG 레이저를 이용한 치아교정 급속 구개확장장치 용접특성)

  • Yoo, Young-Tae;Yang, Yun-Seok;Shin, Ho-Jun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.40-49
    • /
    • 2010
  • The Purpose of this paper is to weld a rapid palatal expander using a continuous wave Nd:YAG laser. The rapid palatal expander has become a useful treatment method for severe maxillary transverse deficiencies and posterior crossbites. Rapid maxillary expansion is a well-established method to correct transverse maxillary deficiency and arch length discrepancy. The major process parameters studied in the present laser welding experiment were the positions of focus, laser power and travel speed of laser beam. We measured the fusion zone size and its shape using an optical microscope for the observation of cross-sectional area and tension stress of a rapid palatal expander welded. Through the experimental investigation, the optimum speeds and power of laser without deficiencies of weld cross-sectional area were obtained.

Prediction of Air Pocket Pressure in Draw Die during Stamping Process (드로우 금형의 에어포켓 수축에 따르는 내부공기 압력예측에 대한 연구)

  • Koo, Tae-Kyong;Hwang, Se-Joon;Park, Warn-Gyu;Oh, Se-Wook
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.6
    • /
    • pp.10-18
    • /
    • 2008
  • Metal stamping is widely used in the mass-production process of the automobile industry. During the stamping process, air may be trapped between the draw die and the panel. The high pressure of trapped air induces imperfections on the panel surface and creates a situation where an extremely high tonnage of punch is required. To prevent these problems, many air ventilation holes are drilled through the draw die and the punch. The present work has developed a simplified mathematical formulation for computing the pressure of the air pocket based on the ideal gas law and isentropic relation. The pressure of the air pocket was compared to the results by the commercial CFD code, Fluent, and experiments. The present work also used the Bisection method to calculate the optimum cross-sectional area of the air ventilation holes, which did not make the pressure of the air pocket exceed the prescribed maximum value.

Development of an Electrical Capacitance Tomography Code for Analysis of Two-Phase Flow in the Rectangular Pipe (사각관 이상유동 분석을 위한 전기적 캐패시턴스 토모그라피 코드 개발)

  • Lee, Kyoung-Hwang;Lee, Jae-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.87-94
    • /
    • 2005
  • A computer code for Electrical Capacitance Tomography (ECT) is developed to sense the cross sectional phase distribution of two-phase flow in the rectangular pipe in which the tomography sensor furnished by the insulated wall, electrodes, and electric field screen. The computer code had two steps for the image reconstruction. In the forward projection step, the sensitivity matrix was constructed based on the electric field calculated by the finite difference method. In the backward projection step, the sensitivity matrix and the measured capacitances were used to reconstruct the cross sectional image. Several algorithms including LBP, TR, ITR, and PLI were employed to find the proper one for the two-phase flow analysis. Since the dielectric constant of the water in two-phase flow is sensitive to the thermal parameter such as, temperature and pressure, the developed code was evaluated to find their accuracy, speed of calculation, and sensitivity to the variation of the dielectric constant. It was found that the iterative methods are superior to the direct methods for the image reconstruction, and the PLI method was the best in the variation of the dielectric constants.

Mechanical Analysis of Macro-Hexagon Porous Dental Implant Using Selective Laser Melting Technique (SLM법으로 매크로 육각다공질 구조를 부여한 치과 임플란트의 역학 분석)

  • Kim, Bu-Sob;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.55-61
    • /
    • 2011
  • Purpose: In this study, FEM(Finite Element Method) and bending strength test was conducted using normal implant and porous implant for the mechanical estimation of porous dental implant made by SLM method. Methods: Mechanical characteristics of PI(porous implant) and NI(normal implant) applied distributed loads(200N, 500N) were observed through FEM analysis. And each bending strength was gotten through bending test using MTS(Mechanical Test System, Instron 8871). Results: The result of FEM analysis was observed that stress difference between upper and surface of PI was 12 times, while NI was 2 times. The result of bending test was observed that bending strength of PI was lower than NI. we made a decision about this result that cross-sectional area of NI was larger than the PI. Conclusion: The stress shielding ability of porous implant was better than normal implant through result of FEM analysis. And bending strength of porous implant was lower than NI. We think that cause of this result was difference of cross-sectional area.

A Case Study of Assessment of the Ecological Connectivity of Cross Sectional Structures in the Flowing Stream (하천 내 횡단구조물에 대한 수생태 연속성 평가 방안에 대한 연구)

  • Choi, Heung Sik
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.4
    • /
    • pp.320-326
    • /
    • 2020
  • The present study aimed to assess the longitudinal connectivity owing to migrant characteristics of the target fish. The study area was Wonju-cheon Stream, and the target species were Zacco platypus and Minnows. The HEC-RAS model was used for the computation of the flow, and the ICE (Information sur la Continuite Ecologique) method was used to analyze the longitudinal connectivity. The longitudinal connectivity was assessed using the minimum overflow height, velocity, and depth of the cross sectional structure of a plunge pool and considering the swimming speed of the target fish. Simulation results indicated that the longitudinal connectivity scores for the Zacco platypus and Minnows were approximately 76 and 23, respectively.

A Study on the Measurement and the Analysis of Radar Cross Section of the Scaled Aircraft Model (축소형 항공기 모델의 레이다 단면적 분석 및 측정에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1055-1060
    • /
    • 2020
  • This study is a study on the analysis and measurement of the radar cross-sectional area of a miniature aircraft. Radar cross-sectional area for miniature aircraft in advance were analyzed using an electromagnetic analysis tool, and an actual miniature aircraft was manufactured and measured in an anechoic chamber. When measuring, the old model was used as reference data for RCS(radar cross section) characteristics and applied to the test result data of the actual reduced model. The measurement method improved the accuracy of the measurement by applying time gating to remove the influence on the components scattered inside the anechoic chamber. The RCS test results of the reduced model showed relatively high RCS characteristics in the microwave band, as the previous analysis results. In the future, we plan to utilize the method of RCS analysis and measurement for the target of the radar in the VHF(Very High Frequency)/UHF(Ultra High Frequency) band with a relatively large wavelength.

Correlation of Tracheal Cross-sectional Area with Parameters of Pulmonary Function in COPD (만성 폐쇄성 폐질환에서 기관의 단면적과 폐기능지표와의 상관관계)

  • Lee, Chan-Ju;Lee, Jae-Ho;Song, Jae-Woo;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Chung, Hee-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.628-635
    • /
    • 1999
  • Background : Maximal expiratory flow rate is determined by the size of airway, elastic recoil pressure and the collapsibility of airway in the lung. The obstruction of expiratory flow is one of the major functional impairments of emphysema, which represents COPD. Nevertheless, expiratory narrowing of upper airway may be recruited as a mechanism for minimizing airway collapse, and maintaining lung volume and hyperinflation by an endogenous positive end-expiratory pressure in patients with airflow obstruction. We investigated the physiologic role of trachea in respiration in emphysema. Method : We included 20 patients diagnosed as emphysema by radiologic and physiologic criteria from January to August in 1997 at Seoul Municipal Boramae Hospital. Chest roentgenogram, high resolution computed tomography(HRCT), and pulmonary function tests including arterial blood gas analysis and body plethysmography were taken from each patient. Cross-sectional area of trachea was measured according to the respiratory cycle on the level of aortic arch by HRCT and calibrated with body surface area. We compared this corrected area with such parameters of pulmonary function tests as $PaCO_2$, $PaO_2$, airway resistance, lung compliance and so on. Results : Expiratory cross-sectional area of trachea had significant correlation with $PaCO_2$ (r=-0.61, p<0.05), $PaO_2$ (r=0.6, p<0.05), and minute ventilation (r=0.73, p<0.05), but inspiratory cross-sectional area did not (r=-0.22, p>0.05 with $PaCO_2$, r=0.26, p>0.05 with $PaO_2$, and r=0.44, p>0.05 with minute ventilation). Minute ventilation had significant correlation with tidal volume (r=0.45, p<0.05), but it had no significant correlation with respiratory frequency (r=-0.31, p>0.05). Cross-sectional area of trachea had no significant correlation with other parameters of pulmonary function including $FEV_1$, FVC, $FEV_1$/FVC, peak expiratory flow, residual volume, diffusing capacity, airway resistance, and lung compliance, whether the area was expiratory or inspiratory. Conclusion : Cross-sectional area of trachea narrowed during expiration in emphysema, and its expiratory area had significant correlation with $PaCO_2$, $PaO_2$, and minute ventilation.

  • PDF

Aging-Related Changes in Hand Intrinsic and Extrinsic Muscles and Hand Dexterity : an MRI Investigation

  • Hsu, Jeffrey;Koh, Kyung;Park, Yang-Sun;Kwon, Hyun-Joon;Kim, Yoon-Hyuk;Shin, Joon-Ho;Shim, Jae-Kun
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.4
    • /
    • pp.371-381
    • /
    • 2015
  • Object : The purpose of this study was to investigate aging-related changes of intrinsic and extrinsic hand muscles in their strength, cross-sectional area and volume, force control, and multi-digit synergies. It was hypothesized that aging would negatively affect distal muscles (intrinsic muscles) more than proximal muscles (extrinsic muscles). Method : Nine young and eleven older right-handed participants underwent MRI scans of the hand and forearm. Muscle cross-sectional areas and volumes of the intrinsic and extrinsic hand muscles were determined. Result : Muscle volume of the intrinsic muscles were larger in the younger group than the older group while muscle volume of the extrinsic muscles did not differ. For the cross-sectional area, both the intrinsic and extrinsic muscles of the younger group were larger than the older group. The maximum strength of the intrinsic muscles of the young group was 31% greater than the older group ($399.1{\pm}26.4$ vs $270.2{\pm}22.9Ncm$, p < 0.05) while the extrinsic muscles showed no significant difference. Although the elderly group showed a trend of decreased force control and multi-digit synergies, no statistical differences were found. These findings indicate aging-related decreases in hand muscle size and strength affect intrinsic muscles more than extrinsic muscles, thus supporting the hypothesis that sarcopenia affects the muscle size and strength of distal muscles more than proximal muscles. Conclusion : The aging-related decreases in hand muscle size and function were more apparent in intrinsic hand muscles, located more distally, than extrinsic muscles, located more proximally.