• Title/Summary/Keyword: cross flow

Search Result 2,028, Processing Time 0.024 seconds

Turbulent Dispersion Behavior of a Jet Issued into Thermally Stratified Cross Flows(I) (열적으로 성층화된 횡단류에 분출된 제트의 난류확산 거동(I))

  • Kim, Kyung Chun;Kim, Sang Ki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.218-225
    • /
    • 1999
  • Flow visualization study has been conducted to simulate the turbulent dispersion behavior of a crossflow jet physically under the conditions of various thermal stratification in a wind tunnel. A smoke jet with the constant ratio of the jet to freestream velocity is injected normally to the cross flow of the thermally stratified wind tunnel(TSWT) for flow visualization. The typical natures of the smoke dispersion under different thermal stratifications such as neutral, weakly stable, strongly stable, weakly unstable, strongly unstable and inversion layer are successfully reproduced in the TSWT. The Instantaneous velocity and temperature fluctuations are measured by using a cold and hot-wire combination probe. The time averaged dispersion behaviors, the centerline trajectories, the spreading angles and the virtual origins of the cross jet are deduced from the edge detected images with respect to the stability parameter. All the general characteristics of the turbulent dispersion behavior reveal that the definitely different dispersion mechanisms are inherent in both stable and unstable conditions. It is conjectured that the turbulent statistics obtained in the various stability conditions quantitatively demonstrate the vertical scalar flux plays a key role in the turbulent dispersion behavior.

Separation of Antibiotics-Producing Mycelia by Cross-Flow Filteration (Cross-Flow Filtration에 의한 항생물질 생산 균사체의 분리)

  • 정상철;윤종원
    • KSBB Journal
    • /
    • v.4 no.2
    • /
    • pp.177-184
    • /
    • 1989
  • In separating mycelia from antibiotic fermentation broths, high permeate flux was obtained by cross-flow filtration using modified regenerated cellulose membrane. The flux was increased most effectively by increasing the flow rate. There existed a critical mycelium density (about 20% PMV) at which the highest flux was observed. In a batchwise concentration of the fermentation broth, the system suffered from a severe fouling problem, which was relieved drastically by applying diafiltration technique, although it increased the permeate volume. A combined concentration/diafiltration process was ideal in keeping relatively high flux together with a high product recovery yield. The best result was obtained by starting diafiltration after concentrating the broth to 20% PMV. By doing so, a 98% product recovery yield was achieved in the shortest time while keeping the permeate volume at a minimum level.

  • PDF

Shore Attachement of Jet in Flowing Environment (흐름수역에서 ?흐름의 연안귀환)

  • Yoon, Tae Hoon;Yook, Woon Soo;Han, Woon Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4_1
    • /
    • pp.43-52
    • /
    • 1992
  • The shore attachment of jet in a cross flow is analysed by experiments and dimensional analysis. The jet flow is discharged with the same depth as that of the cross flow through a side channel perpendicular to the cross flow through a side channel perpendicular to the cross flow. For a momentum jet, nondimensional attachment length and height are dependent on nondimensional characteristic length $I_m/W$. For a buoyant jet, nondimensional attachment length is affected by $I_b/I_md$ and nondimensional temperature distribution is a function of $x/I_b$ and they all can be predicted as power laws. The shore attachment condition can be specified by velocity ratio R.

  • PDF

Efficiency of Marine Hydropower Farms Consisting of MultipleVertical Axis Cross-Flow Turbines

  • Georgescu, Andrei-Mugur;Georgescu, Sanda-Carmen;Cosoiu, Costin Ioan;Alboiu, Nicolae
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.150-160
    • /
    • 2011
  • This study focuses on the Achard turbine, a vertical axis, cross-flow, marine current turbine module. Similar modules can be superposed to form towers. A marine or river hydropower farm consists of a cluster of barges, each gathering several parallel rows of towers, running in stabilized current. Two-dimensional numerical modelling is performed in a horizontal cross-section of all towers, using FLUENT and COMSOL Multiphysics. Numerical models validation with experimental results is performed through the velocity distribution, depicted by Acoustic Doppler Velocimetry, in the wake of the middle turbine within a farm model. As long as the numerical flow in the wake fits the experiments, the numerical results for the power coefficient (turbine efficiency) are trustworthy. The overall farm efficiency, with respect to the spatial arrangement of the towers, was depicted by 2D modelling of the unsteady flow inside the farm, using COMSOL Multiphysics. Rows of overlapping parallel towers ensure the increase of global efficiency of the farm.

Experimental and numerical study on generation and mitigation of vortex-induced vibration of open-cross-section composite beam

  • Zhou, Zhiyong;Zhan, Qingliang;Ge, Yaojun
    • Wind and Structures
    • /
    • v.23 no.1
    • /
    • pp.45-57
    • /
    • 2016
  • Open-cross-section composite beam (OCB) tends to suffer vortex-induced vibration (VIV) due to its bluff aerodynamic shape. A cable-stayed bridge equipped with typical OCB is taken as an example in this paper to conduct sectional model wind tunnel test. Vortex-induced vibration is observed and maximum vibration amplitudes are obtained. CFD approach is employed to calculate the flow field around original cross sections in service stage and construction stage, as well as sections added with three different countermeasures: splitters, slabs and wind fairings. Results show that flow separate on the upstream edge and cause vortex shedding on original section. Splitters can only smooth the flow field on the upper surface, while slabs cannot smooth flow field on the upper or lower surface too much. Thus, splitters or slabs cannot serve as valid aerodynamic means. Wind tunnel test results show that VIV can only be mitigated when wind fairings are mounted, by which the flow field above and below the bridge deck are accelerated simultaneously.

Experimental Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Curvature Radius of a Rear-Guider for a Room Air-Conditioner (리어가이더 곡률반경에 따른 룸에어콘용 관류홴의 공력성능에 대한 실험적 연구)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.36-44
    • /
    • 2013
  • The aerodynamic performance of a cross-flow fan is strongly influenced by the various design factors of a rear-guider and a stabilizer. The design factors considered in this paper are a rear-guider clearance, a stabilizer clearance, and a stabilizer setup angle, respectively. Also, these factors are given to the various diameter ratio between a basic circle and a impeller. The static pressure and the flowrate of a cross-flow fan were measured with a fan-tester. It could be found that the useful design factors with a good aerodynamic performance exist in the certain assembly conditions of an indoor RAC. Therefore, it could be known that a new published patent determining the easy design of an indoor RAC can be applied in a variety of goods.

Characteristics Analysis of Debris Flow Disaster in Korean National Parks (국립공원 지역에 있어서 토석류 재해의 특성 분석)

  • Ma, Ho-Seop;Jeong, Won-Ok
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.4
    • /
    • pp.52-64
    • /
    • 2010
  • This study was carried out to analyze the occurrence characteristics and the influence of forest environment factors on the debris flow of 3 national parks in korea. The results obtained from this study were summarized as follows; The total number of debris flow occurrence was 125 areas. The average length of the debris flow scar was 144m, average width was 20m. And the average area and sediment were $2,854m^2$ and $3,959m^3$ respectively. The factors influencing the debris flow were highly occurred in Metamorphic rock, mixed forest type. And also, slope gradient was $30{\sim}35^{\circ}$, aspect was NE, altitude was over 1,000m, vertical and cross slope was concave (凹), soil depth was below 15cm, stream order was 0 order. The variables of cross slope (complex), deciduous tree, soil depth (over 46cm), cross slope (concave), mixed forest type and altitude (801~1200m) in correlation analysis were significant at 1 % level. The landslide of high mountain area highly tend to change the debris flow in stream bed of torrent. The debris flow in national parks mainly occurred in high mountain area with long ridge and steep slope.

An Experimental Study on the Transmission Loss of Perforated Tube Mufflers (다공관 소음기의 투과손실에 관한 실험적 연구)

  • 김찬묵;사종성;방극호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.346-352
    • /
    • 2002
  • This paper is the experimental study to estimate the influence of various design parameters on the performance of mufflers with perforated tubes and through-flow partitions. Muffler types considered in the present work include through-flow chamber, through-flow chamber with partition, and cross-flow chamber. The influences of the design parameters on the performance of the mufflers can be outlined as follows. In the case of the through-f]ow type mufflers, increasing the tube thickness and the hole diameter of the perforated tubes does not change the maximum value of the transmission loss but decrease the cutoff frequency. In the case of the through-flow with partitions type mufflers, it is shown that combining a fe w short chambers and long chambers can modify the frequency locations of the resonance frequencies to optimize the performance of the mufflers. For the case of the cross-flow type mufflers, it is shown that the transmission loss of the mufflers is mainly affected by the lower porosity when the porosities are different in both sides of the plug. Overall, it is shown that performance of the through-flow type with partition type mufflers is excellent in the lower frequency region, where the cross-flow type mufflers have better performance in the higher frequency region.

  • PDF

Study on Flow Structure inside Room Air Conditioner Using Visualization Technique (가시화기법을 이용한 룸 에어컨 내부의 유동 구조에 관한 연구)

  • Lee, Soo-Hong;Na, Seon-Uk;Kang, Geun;Ko, Han-Seo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2713-2717
    • /
    • 2008
  • Whole flow fields of a room air conditioner (RAC) have been visualized by a Particle Image Velocimetry (PIV) technique to analyze the flow structure with various inlet and outlet angles, and to control an eccentric vortex which affects an efficiency and noise of the RAC. A test model with 5 stages of a cross flow fan has been manufactured and a transparent acryl has been installed at the side of the test model for the PIV experiment. The inlet and outlet flows and the flow inside the cross flow fan have been analyzed by varying the inlet grill angles and outlet blade angles. The movement of the eccentric vortex has been investigated experimentally by developing the measurement technique for the inner flow field of the cross flow fan. From the visualization of the inner flows, the origins of the noise inside the RAC and the condensation points around the outlet parts of the cold air have been observed and the solution of the problems can be proposed in this study.

  • PDF

Air Layer Effect on the Performance Improvement of a Cross-Flow Hydro Turbine

  • Choi, Young-Do;Shin, Byeong-Rog;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.37-43
    • /
    • 2010
  • The purpose of this study is not only to investigate the effects of air layer in the turbine chamber on the performance and internal flow of the cross-flow turbine, but also to suggest a newly developed air supply method. Field test is performed in order to measure the output power of the turbine by a new air supply method. CFD analysis on the performance and internal flow of the turbine is conducted by an unsteady state calculation using a two-phase flow model in order to embody the air layer effect on the turbine performance effectively. The result shows that air layer effect on the performance of the turbine is considerable. The air layer located in the turbine runner passage plays the role of preventing a shock loss at the runner axis and suppressing a recirculation flow in the runner. The location of air suction hole on the chamber wall is very important factor for the performance improvement. Moreover, the ratio between air from suction pipe and water from turbine inlet is also significant factor of the turbine performance.