• 제목/요약/키워드: critical source area

검색결과 77건 처리시간 0.024초

대구지역 대기 중 VOCs 농도 및 발생원 특성 (Characteristics of Source and Concentration of VOCs in Daegu)

  • 구민정;최성우
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.543-553
    • /
    • 2005
  • In recent days, photochemical smog due to the rapid industry development and vehicle increasement has become a critical pollutant in the metropolitan area and the number of ozone alarm signal has increased every year. This research was performed to evaluate VOCs emission source characteristics and concentration of VOCs in Daegu. The site average concentration was observed in the following order: industrial area > commercial area > residential area. Most of the VOCs species except toluene showed variations with higher concentration during nighttime, and lower concentration during the daytime. The major VOCs of stationary emission source were BTEX(benzene, toluene, ethylbenzene. xylene) and methylene chloride, trichloroethene and styrene. Also, those of automobile exhaust were toluene and benzene. Also, the major VOCs concentration emited by the vehicle fuel was observed in the following order: gasoline > light oil > liquefied petroleum gas (L.P.G). Correlation coefficients values were estimated between major VOCs such as toluene, ethylbenzene, m,p-xylene, o-xylene. Results showed that correlation coefficient values were significant magnitude above 0.76. Also, there showed highly significant correlations among ethyl benzene, m,p-xylene, and o-xylene concentration(Pearson correlation coefficients, r=0.868-0.982). Calculated correlation coefficients among commercial area,industrial area and residential area were 0.934-0.981, they showed high correlation. There showed highly correlation between stationary emission source and industrial area, compared with commercial area and residential area. Also, calculated correlation coefficients among commercial area, industrial area, residential area and automobile exhaust were 0.732, 0.725, 0.777, respectively.

Enhancement of the Critical Heat Flux by Using Heat Spreader

  • Yoon, Young-Sik;Hyup Yang;Kwak, Ho-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제17권7호
    • /
    • pp.1063-1072
    • /
    • 2003
  • Direct immersion cooling has been considered as one of the promising methods to cool high power density chips. A fluorocarbon liquid such as FC-72, which is chemically and electrically compatible with microelectronic components, is known to be a proper coolant for direct immersion cooling. However, boiling in this dielectric fluid is characterized by its small value of the critical heat flux. In this experimental study, we tried to enhance the critical heat flux by increasing the nucleate boiling area in the heat spreader (Conductive Immersion Cooling Module). Heat nux of 2 MW/㎡ was successfully removed at the heat source temperature below 78$^{\circ}C$ in FC-72. Some modified boiling curves at high heat flux were obtained from these modules. Also, the concept of conduction path length is very important in enhancing the critical heat flux by increasing the heat spreader surface area where nucleate boiling occurs.

BASINS-SWAT 모델을 이용한 경안천 유역의 비점원 오염배출 중점관리 대상지역 결정 (Decision of Critical Area Due to NPS Pollutant Loadings from Kyongan Stream Watershed using BASINS-SWAT)

  • 장재호;윤춘경;정광욱;손영권
    • 한국농공학회논문집
    • /
    • 제51권5호
    • /
    • pp.69-78
    • /
    • 2009
  • In order to improve water quality of upper watershed of Paldang reservoir, it is necessary to evaluate non-point source pollution loads and identify critical watershed pollution sources. A GIS based Soil and Water Assessment Tool was applied to evaluate model application and reliability, estimate NPS pollution load, identify critical watershed by NPS pollution sources, and suggest various best management practices for Kyongan Stream watershed. Yearly NPS pollution loads were estimated 30.0% SS, 60.1% TN and 35.4% TP, respectably. The watershed pollution load is mainly decided by precipitation condition and SS and nutrients load have a significant regression relationship. Based on 10-year average yearly NPS pollution load, critical sub-watersheds were identified. The No. 5 and 17 which have lots of relatively intensive agricultural fields and scattered industrial area were vary critical sub-watersheds and under more intensive pollution load. In order to control critical watershed, watershed best management practices such as scientific fertilizer, contour farming and parallel terrace, transferring the sloppy farmland to grass or forest and constructing a buffer zone, and constructing wetlands and retention ponds will be applied. Overall the SWAT model can be efficiently used for identification of critical sub-watersheds in order to develop a priority watershed management plan to reduce water pollutions.

효과적인 도시 홍수 저감을 위한 그린-그레이 인프라 위치 설정에 관한 연구 (A Study on Optimized Placement of Green-Gray Infrastructure for Effective Flood Mitigation)

  • 배채영;이동근
    • 한국환경복원기술학회지
    • /
    • 제25권6호
    • /
    • pp.65-75
    • /
    • 2022
  • Urban flood management(UFM) strategy ought to consider the connections and interactions between existing and new infrastructures to manage stormwater and improve the capacity to treat water. It is also important to demonstrate strategies that can be implemented to reduce the flow at flooding sources and minimize flood risk at critical locations. Although the general theory of spatial impact is popular, modeling guidelines that can provide information for implementation in real-world plans are still lacking. Under such background, this study conducted a modeling research based on an actual target site to confirm the hypothesis that it is appropriate to install green infrastructure(GI) in the source area and to take structural protection measures in the impact area, as summarized in previous studies. The results of the study proved the hypothesis, but the results were different from the hypothesis depending on which hydrological performance indicators were targeted. This study will contribute to demonstrating the effectiveness of strategies that can be implemented to reduce the flow at flooding sources and minimize the risk of flooding in critical locations in terms of spatial planning and regeneration.

하천수질자료를 이용한 농촌하천유역 오염원의 규명 (Identification of Critical Source Areas on Water Quality in a Rural Watershed)

  • Hong, Seong;Kwun, Soon Kuk
    • 한국농공학회지
    • /
    • 제43권5호
    • /
    • pp.145-152
    • /
    • 2001
  • 농촌유역하천에서 수집된 수질측정자료를 이용하여 주요 오염원을 규명하였다. 분석에 이용된 수질항목은 BOD, COD. EC, pH. TN, TP,$NO_3-N,PO_4-P$ 등으로서 하천 본류내 구간별로 쌍대비교를 통해서 항목별 차이에 대한 유의성 검정을 하였다. 유의성 검정에 이용된 방법은 쌍대비교를 위한 비모수검정법인 Wilcoxon 순위검정법을 이용하였다. 검정결과, 유기성 오염물질의 지표로 이용되는 BOD와 COD가 상승하는 구간은 주로 생활하수가 유입되는 구간으로 나타났다. 인구밀도가 매우 높으나 생활하수가 처리장으로 배제되는 지역의 하천구간에서는 이들 농도변화는 없었다. 유역 내 축산농가가 밀집되어 있는 지역의 하천구간에서도 농도의 변화 또한 존재하지 않았다. 본 연구에서 조사된 유역에서와 같이 축산분뇨를 퇴비화 및 농지환원하는 경우에는 하천수질에 거의 영향을 미치지 않는다는 것을 알 수 있었다. 따라서 농촌지역의 하천 수질을 개선하기 위해서는 생활하수에 대한 처리가 선행되어야 한다.

  • PDF

도로터널 임계풍속 산정에 격자개수 및 화원의 크기와 위치가 미치는 영향 (The effect of grid number and the location and size of the fire source on the critical velocity in a road tunnel fire)

  • 이승철;김상일
    • 한국터널지하공간학회 논문집
    • /
    • 제14권3호
    • /
    • pp.183-195
    • /
    • 2012
  • 본 연구에서는 도로터널 내 화재 시 임계풍속 산정을 위해 3차원 전산유체역학 기법을 이용하여 격자수, 그리고 화원의 크기와 위치에 따라 그 결과를 비교 분석하였다. 본 대상터널에서 1차원 식으로 산출된 임계풍속은 터널 높이 대신 수력지름을 적용한 경우 2.22 m/s로 산정되었다. 임계풍속 2.25 m/s를 적용하여 격자수에 따른 6가지 수치해석 결과, 격자수에 따라 역류의 위치와 온도, CO 농도 값이 상이하게 나타났으며, 본 대상터널의 경우는 약 84만개 격자수를 사용한 case 1이 적절한 격자임을 알 수 있었다. 또한 화원의 크기와 위치에 따른 수치해석 결과, 화원의 크기와 위치에 따라 상이한 기류분포, 온도분포 및 CO농도분포를 나타내어 임계풍속에 영향을 미친다는 것을 확인했다. 이것은 열교환 면적과 위치에 기인된다고 판단된다. 향후 실제 실험결과와 상세히 비교하여 3차원 수치해석의 격자 의존성과 화원의 위치 및 크기를 반드시 확인해야 할 것으로 판단된다.

XML에 기반을 둔 C 원시 코드의 주석 관리 시스템 (An XML-based Comment Management System for C Source Code)

  • 박근옥;임종태
    • 정보처리학회논문지D
    • /
    • 제11D권4호
    • /
    • pp.799-808
    • /
    • 2004
  • C 언어가 주로 사용되는 미션 크리티컬 응용 소프트웨어 영역에는 문서화, 간결성, 정확성을 갖는 원시 코드가 요구된다. 본 연구는 XML 기반의 C 원시 코드의 주석관리 체계를 제안한다. 이 주석 관리체계는 주석 사용자 모듈, 검토자 모듈, 주석 추출 모듈, 주석 추적 연계 모듈, 주석 태그 정의 모듈, 저장관리 모들을 포함하는 6개 모듈로 구성된다. 본 연구에서 정의된 XML 주석 태그는 IEEE 표준 1028과 IEEE 표준 1012를 적용하는 개발공정 활동의 범주를 포함한다. C 원시 코드에 주석을 삽입하고 추출하기 위하여 XML 스키마가 사용되며. 주석 추출 결과의 시각적 표시 처리를 위하여 XSL-FO가 사용된다.

직접수치해법을 이용한 난류 예혼합 화염전파속도 연구 (Roles of displacement speed of premixed flame embedded in isotropic turbulent decaying flow)

  • 한인석;허강열
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.177-186
    • /
    • 2006
  • Flame surface area is a critical parameter determining turbulent flame speed. Three-dimensionaldirect numerical simulations (DNS) were conducted to figure out the evolution process of flame surface area. Fully compressible Navier-Stokes equations are solved to reproduce premixed flame embedded in isotropic decaying turbulent flow. The tangential straining and curvature of propagating surface affect development of flame area. In this study, four different turbulent intensity flows and three different Le number flames are investigated to force changes in straining and curvature effects. Consistent results are obtained for the probability density functions (PDF) of strain and curvature with previous researches. It is revealed that displacement speed, which is a speed of flame surface relative to unburnt flow, controls the balance between sink and source of flame surface area.

  • PDF

직접수치해법을 이용한 난류 예혼합 화염전파속도 연구 (Roles of Displacement Speed of Premixed Flame Embedded in Isotropic Turbulent Decaying Flow)

  • 한인석;허강열
    • 한국연소학회지
    • /
    • 제12권2호
    • /
    • pp.10-19
    • /
    • 2007
  • Flame surface area is a critical parameter determining turbulent flame speed. Three-dimensional direct numerical simulations(DNS) were conducted to figure out the evolution process of flame surface area. Fully compressible Navier-Stokes equations are solved to reproduce premixed flame embedded in isotropic decaying turbulent flow. The tangential straining and curvature of propagating surface affect development of flame area. In this study, four different turbulent intensity flows and three different Le number flames are investigated to force changes in straining and curvature effects. Consistent results are obtained for the probability density functions (PDF) of strain and curvature with previous researches. It is revealed that displacement speed, which is a speed of flame surface relative to unburnt flow, controls the balance between sink and source of flame surface area.

  • PDF

Non-point Source Critical Area Analysis and Embedded RUSLE Model Development for Soil Loss Management in the Congaree River Basin in South Carolina, USA

  • Rhee, Jin-Young;Im, Jung-Ho
    • Spatial Information Research
    • /
    • 제14권4호
    • /
    • pp.363-377
    • /
    • 2006
  • 본 연구에서는 개정범용토양유실공식(RUSLE: Revised Universal Soil Loss Equation)을 이용하여 미국 South Carolina 주 Congaree 유역에 대한 평균 연간 토양 유실량을 산출 하였으며 비점오염원 토양 유실 민감지역을 추출하였다. 평균 연간 토양 유실량은 강우-유출 침식성 인자, 토양침식성 인자, 지면특성 인자, 식생피복 인자, 그리고 토양보존 인자의 곱으로 계산할 수 있으며, 토양 유실 민감지역은 토양 유실량이 토양침식 허용량을 초과하는 지역으로 추출할 수 있다. 연구 결과, 전체 면적의 10% 이상의 면적이 비점오염원 토양 유실 민감 지역으로 확인되었으며, Congaree 유역의 7개 소유역중 Congaree Creek, Gills Creek 소유역의 도심지역과 Cedar Creek 소유역의 농업지역에서 가장 심각한 토양 유실의 위험이 나타났다. 관심 지역의 인위적, 자연적 변화가 토양 유실에 가져오는 영향을 살펴보기 위한 시범 모형으로서, 개정범용토양유실공식에 기초한 내장형 모형이 Visual Basic for Applications (VBA)를 이용하여 ESRI사의 ArcGIS ArcMap 9.0에서 사용할 수 있도록 개발되었다. 이 내장형 모형에서 사용자는 각 소유역의 토지 피복, 식생 유형, 지표 식생 유형, 경사, 작물 유형, 경작 방식 등을 변경시킴으로써 C, LS, P 인자를 변화시킬 수 있으며, 계산된 평균 연간 토양 유실량과 민감 지역을 현재 상태의 값들과 비교하여 앞으로의 토양유실 관리를 위한 주요 정보로 사용할 수 있다.

  • PDF