• Title/Summary/Keyword: criteria pollutant

Search Result 111, Processing Time 0.027 seconds

A Study on the Application and Design Procedure of Multi-Purpose Wet Detention Ponds for Improving Water Quality - Case Study of NamAk New Town Development Area - (다목적 저류지의 수질개선을 위한 설계과정 및 적용에 관한 연구 - 남악 신도시 개발지를 대상으로 -)

  • Woo, Chang-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.1
    • /
    • pp.97-109
    • /
    • 2004
  • The disposal of stormwater is one of the major problems in urban water management. One method of reducing peak runoff rates and other detrimental impacts of stormwater is detention storage. Detention ponds as a water quality control alternatives have been investigated by a number of researchers. Recognizing multiple roles such as flood peak attenuation, pollution removal and aesthetic enhancement, the design and management of detentions ponds deserve more research. The purpose of this research is to establish design criteria wet detention ponds to improve water quality. Water quality in detention pond discharge might be improve with physical, chemical and biological alterations. Physical alteration was focused in this study. There are several methods for estimating the suspended solid control capability of wet detention ponds. Existing models of suspended solids removal are based on sedimentation and gravity settling theory. The pollutant trap efficiency of pond is a function of several interrelating factors. Detention time is the most important factor, because it determine gravity settling quantities of pollutants. Desirable modification of physical factors for improvement of water quality in wet detention ponds are volume ratio, area ratio, length to width ratio, depth, out let location, bottom soil type. In order to apply design procedure in actual site, Namak new town development area was selected.

Evaluation of Physical, Mechanical Properties and Pollutant Emissions of Wood-Magnesium Laminated Board (WML Board) for Interior Finishing Materials

  • PARK, Hee-Jun;JO, Seok-Un
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.86-94
    • /
    • 2020
  • This study serves as basic research for the development of a new wood-based building finishing material that improved the weakness of inorganic materials such as gypsum board and magnesium board widely used as interior finishing materials and brought out the strength of the wood. The results of evaluating the physical and mechanical properties and the environmental effect related to hazardous substance discharge having manufactured a wood-magnesium laminated composite are as follows. The thermal conductivity and thermal resistance of WML board was improved by about 28~109 percent over magnesium board due to the low thermal conductivity of wood. The adhesive strength of WML board showed a similar result to that of plywood as it exceeds 0.7N/㎟, the adhesive standard of wood veneer which is presented by KS F 3101. Bending strength and screw holding strength were more improved by manufacturing WML board than magnesium board. The WML board manufactured in this study satisfied the criteria for emissions of hazardous substances prescribed in the Indoor Air Quality Control Act, and confirmed the possibility of development as a new wood-based composite material that can replace existing inorganic materials.

A study on Development and Application of Sequential Control Algorithm of Ventilation and Air Cleaning System for Improving Indoor Air Quality in School Classroom (학교교실의 실내공기질 개선을 위한 환기장치 및 공기청정기의 연동제어 알고리즘 개발 및 적용 연구)

  • Park, Hwan-Chul;Lee, Dong-Hyeon;Yee, Jurng-Jae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.5
    • /
    • pp.187-194
    • /
    • 2020
  • This study presents the energy-saving sequential control algorithm to handle indoor CO2 and PM2.5 for the improvement of the air quality of school classrooms. To solve indoor air quality (IAQ) problems, air cleaning and ventilation systems are mainly used for school classrooms. Although air cleaning is able to collect PM2.5, it is difficult to remove harmful gas substances. The ventilation system is suitable to tackle CO and CO2, the volume ventilation, however, is relatively small. In this paper, to remove CO2 and PM2.5, the pollutant balance equation for improving indoor air quality is reviewed. The sequential control algorithm of the ventilation and air cleaning system with four levels of criteria is introduced for the effective removal of pollutants. The proposed sequential control algorithm confirms that indoor CO2 and PM2.5 can be properly controlled below the standard value. In addition, the sequential operation of air cleaning and ventilation systems has shown significant improvement in IAQ compared to the independent ventilation system operation. Particularly, such systems are efficient when outdoor PM2.5 is high.

Assessment of Pollutant Loads in the Dongjin River (동진강 유역의 오염부하량 평가)

  • Lee, Kyeong-Bo;Kim, Jong-Cheon;Kim, Jong-Gu;Lee, Deog-Bae;Park, Chan-Won;Kim, Jae-Duk
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.2
    • /
    • pp.91-97
    • /
    • 2005
  • This study was conducted to evaluate the influence of pollutant loads on the water quality in the Dongjin River area from January 2003 to December 2004. The average value of BOD and T-N showed the highest peak in Yongho, Dukcheon watershed among Dongjin River. Concentrations of BOD, T-N and T-P in Jeongeup watershed were 2.29 mg $L^{-1}$, 4.40 mg $L^{-1}$ and 0.27 mg $L^{-1}$, respectively. Concentration of BOD in Chilbo was 1.19 mg $L^{-1}$ which would be in the grade I according to water quality criteria by Ministry of Environment. The BOD level in Wonpeung and Sinpeung watershed ranged from 4.06 to 7.35 mg $L^{-1}$. The T-N effluent loads of non-point pollutants were high in Wonpeung, Gobu, Yongho Dukcheon, Jeongeup and Sinpeung watershed in order. The major sources of BOD, T-N and T-P effluent loads were Livestock. The T-P effluent load of non-point pollutant was 68 kg $day^{-1}$ in Wonpeung, 58 kg $day^{-1}$ in Yongho Dukcheon and 45 kg $day^{-1}$ Jeongeup watershed. The delivered loads of BOD was high in Gobucheon, while both T-N and T-P were high in Yongho Dukcheon. The delivery ratio of BOD and T-N at dry season was below 100% in all watershed of Dongjin River. The delivery ratio of T-N at raining season was high in Yongho Dukcheon and Chilbo watershed

Assessment of Pollutant Loads from Alpine Agricultural Practices in Nakdong River Basin (낙동강 수계 고령지 밭의 비점오염 물질 유출 특성 조사 및 단위 유출량 산정)

  • Joo, Jin-Ho;Yang, Jae-E.;Ok, Yong-Sik;Oh, Sang-Eun;Yoo, Kyung-Yeol;Yang, Su-Chan;Jung, Yeong-Sang
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.3
    • /
    • pp.233-238
    • /
    • 2007
  • To assess pollutant loads in Nakdong river from highland agriculture in Kyungbuk province we. analyzed water qualities such as BOD, COD, T-N, T-P and SS in year 2005. BOD values in rainy period (June and July) were relatively higher than those in dry period, and those in 4 sites among 17 sites ranged from 10.71-19.25 mg/L which exceeded water criteria (8 mg/L) for agricultural use. COD values showed similar trends like BOD values. These trends might be caused by outflow of nutrients applied in agricultural lands. T-N content ranged from 0.1 to 14 mg/L. Those in lower reaches of stream were greater in those in upper stream. Compared to T-N contents during non-farming season, T-N content in farming season were higher. These phenomenon could be due to continuous input of nutrients from small watercourses. Averaged T-P content in lower stream during farming season was 0.4 mg/L, which was eight times higher than the limiting level for algae occurrence (0.05 mg/L). BOD, T-P, T-N loads from alpine agricultural practices were 12.25 $kg/km^2{\cdot}day$, 0.55 $kg/km^2{\cdot}day$ and 32.35 $kg/km^2{\cdot}day$, respectively. These values were greater than those from forestry. Therefore, Best management Practices (BMP) for alpine agricultural field are needed to reduce pollutant loads in Nakdong river.

Optimum Capacity of Retention Basin for Treating Nonpoint Pollutants and Its Removal Efficiency in Industrial Complex Areas (산업단지내 비점오염물질 처리를 위한 적정 저류조 용량 산정 및 처리효율)

  • Kim, Lee-Hyung;Lee, Byung-sik;Kwon, Soo-Youl
    • Journal of Wetlands Research
    • /
    • v.7 no.3
    • /
    • pp.75-85
    • /
    • 2005
  • The Construction of industrial complex areas means the increase of imperviousness rate and the increase of nonpoint pollutant emissions during a rainfall. Generally the retention basin can become the alternative for removing and controling these nonpoint pollutants. Recently Ministry of Environment are trying to change the purpose of retention basins from flooding control to nonpoint pollutant control. In order to propel the stormwater management program, administration plan of stormwater management is enacted in Spring, 2005. Hereafter, in a newly developing area, the best management practices should be established to control the nonpoint pollutant. Landuses of the research area are classified to the categories of the 1st manufacturing industry, metal industry, fiber and chemical product manufacturing industry, etc. Therefore, this research was performed to understand washed-off characteristics of stormwater and to suggest the controling method of nonpoint pollutants. The optimum capacity of the retention basin can be determined by analyzing the relationships among data of rainfall, runoff, washed-off pollutants from the areas. The rainfall analysis using the data of normal year, recent 2, 5 and 10 years shows that the 80% rainfall frequency was occurred on 10mm accumulated rainfall, but which is not considered the first flush effect. However, by considering the first flush effect, the appropriate treatment capacity of rainfall can be decreased to 4-5mm accumulated rainfall. Using the criteria, the optimum capacity of retention basin is determined to $12,000m^3$ in the research area. The washed-off nonpoint pollutant loading from the areas have beeb calculated to 435ton/yr for TSS, 238ton/yr for COD, 8,518kg/yr for TKN and 1,816kg/yr for TP. The mass of 78.3ton/yr for TSS, 20.4ton/yr for BOD, 128.6ton/yr for COD, 4.6ton/yr for TKN and 980kg/yr for TP can be reduced by constructing the retention basin. The sediment accumulation rate is also calculated by $6.53kg/m^2-hr$.

  • PDF

Long-term Trend Analysis of Key Criteria Air Pollutants over Air Quality Control Regions in South Korea using Observation Data and Air Quality Simulation (관측자료와 대기질 모사를 이용한 주요 기준성 대기오염물질의 권역별 장기변화 분석)

  • Ju, Hyeji;Kim, Hyun Cheol;Kim, Byeong-Uk;Ghim, Young Sung;Shin, Hye Jung;Kim, Soontae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.101-119
    • /
    • 2018
  • In this study, we analyzed long-term measurements and air quality simulation results of four criteria air pollutants ($PM_{10}$, $O_3$, $NO_2$, and $SO_2$) for 10 years, from 2006 to 2015, with emphasis on trends of annual variabilities. With the observation data, we conducted spatial interpolation using the Kriging method to estimate spatial distribution of pollutant concentrations. We also performed air quality simulations using the CMAQ model to consider the nonlinearity of the secondary air pollutants such as $O_3$ and the influence of long-range transport. In addition, these simulations are used to deduce the effect of long-term meteorological variations on trends of air quality changes because we fixed the emissions inventory while changing meteorological inputs. The nation-wide inter-annual variability of modeled $PM_{10}$ concentrations was $-0.11{\mu}g/m^3/yr$, while that of observed concentrations was $-0.84{\mu}g/m^3/yr$. For the Seoul Metropolitan Area, the inter-annual variability of observed $PM_{10}$ concentrations was $-1.64{\mu}g/m^3/yr$ that is two times rapid improvement compared to other regions. On the other hand, the inter-annual variability of observed $O_3$ concentrations is 0.62 ppb/yr which is larger than the simulated result of 0.13 ppb/yr. Magnitudes of differences between the modeled and observed inter-annual variabilities indicated that decreasing trend of $PM_{10}$ and increasing trend of $O_3$ are more influenced by emissions and oxidation states than meteorological conditions. We also found similar patterns in $NO_2$. However, $NO_2$ trends showed greater regional and seasonal differences than other pollutants. The analytic approach used in this study can be applicable to estimate changes in factors determining air quality such as emissions, weather, and surrounding conditions over a long term. Then analysis results can be used as important data for air quality management planning and evaluation of the chronic impact of air quality.

Evaluation of TVOC regulation level of sealant products in accordance with simultaneous revision of testing method and regulation value in the law of indoor air quality management (실내 공기질 공정시험방법과 기준의 동시 개정에 따른 실란트 제품의 TVOC 관리수준 평가)

  • Yoo, Ji-Ho;Park, Joon-Man;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.138-146
    • /
    • 2010
  • The Korean Ministry of the Environment revised a few sections of the regulations in the Law of indoor air quality management for the reinforcement or adjustment of the regulation criteria standard for releasing pollutants from building materials. Especially, in case of sealant, the contents covering liquid building materials, excess standards and testing methods have been added simultaneously in this revision, As a result it is impossible to compare original standards with revised standards directly. For this reason, this study reviewed revised test method of sealant pollutant emission rates in terms of impact and validity in comparison with the original test method. Through this study, the basic properties of revised pollutant emission control standards was assessed. Especially in sealant, since each product has a wide deviation of time required for complete drying, it is proved that there are a large number of products that are not hardened completely in test time. The result of our experiments on the revised test methods showed that this revised test methods yield emission rates that are two and half times less than those of the original testing method. To apply the revised test method of sealant to all the sealant products, It is necessary to extend the test period or improve specimen to fit the test method for quickly drying sealant products.

The application of ecosystem model for the eutrophication control in Masan Bay in summer (하계 마산만의 부영양화 제어를 위한 생태계모델의 적용)

  • Kim, Jong-Gu;Park, Cheong-Gil;Kim, Gwang-Su
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.185-195
    • /
    • 1994
  • Masan bay is one of the polluted enclosed bays, which has red tides problem and the formation of oxygen deficient water in the bottom layer. Most important factors that cause eutrophication and red tide is nutrient materials containing nitrogen and phosphorus which stem from terrestrial sources and nutrients released from sediment. Therefore, to improve of water quality, reduction of these nutrient loads should be indispensible. At this study, the three-dimensional numerical hydrodynamic and eutrophication model, which were developed by Institute for Resources and Environment of Japan, were applied to analyze the processes affecting the phytoplankton production and also to evaluate the effect of water quality improvement plans on phytoplankton production. In field sorvey, the range of concentrations of chlorophyll-a at surface area was found to be 29.17 - 212.5mg/m3, which were exceeding eutrophication criteria. The constant currents defined by integrating the simulated tidal currents over 1 tidal cycle showed the counterclockwise eddies in the southern part of Budo. The general directions of constant currents were found to be southward at surface and northward at bottom over all the bay. The eutrophication model was calibrated with the data surveyed in the field area in June, 1993. The calculated results are in fairly good agreement with values within relative error of 30%. The pollutant load from the sources such as the input from terrestrial release from the sediment was reduced by the rate of 50, 70, 90, 98% to effect of phytoplankton production. Phytoplankton production was reduced to of the 90% reduction of the input loads from terrestrial sources and 8% in 90% reduction of the load from sediment.

  • PDF

Status of Water Quality and Future Plans in the Philippines (필리핀의 수질현황 및 미래 관리계획)

  • Gorme, Joan B.;Maniquiz, Marla C.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.11 no.3
    • /
    • pp.89-103
    • /
    • 2009
  • The Philippines is abundant with rich natural resources such as water. Because of rapid urbanization in the country, most of the water bodies are polluted as a result of domestic, agricultural and industrial activities. The Environmental Management Bureau (EMB) is the main government arm responsible for monitoring and inspection of affected water bodies. Only water bodies with at least four sampling events during dry and wet seasons were included in the assessment of water bodies that passed the DAO 90-34 water quality criteria. Water bodies were monitored for dissolved oxygen (DO), biochemical oxygen demand (BOD), total suspended solids (TSS), and total dissolved solids (TDS), heavy metals, fecal coliform contamination and nitrates. High pollutant concentrations from domestic, agricultural, industrial and nonpoint sources were observed from monitoring events due to inadequate sewage services and treatment facilities in the country. The objective of this paper was to present and evaluate the quality of the water bodies in the Philippines.

  • PDF