• 제목/요약/키워드: criteria of deterioration

Search Result 154, Processing Time 0.035 seconds

Proposed Development and Evaluation System for Existing Standardized Waterproof Technology Assessment Methods(Production technology, maintenance evaluation) (표준화된 방수기술 평가기법 개발 및 평가체계 구축 (생산기술, 유지관리 평가 중심))

  • Song, Je-Young;Seo, Hyun-Jae;Choi, Eun-Kyu;Lee, Jung-Hun;Kim, Byoungil;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.235-236
    • /
    • 2019
  • Waterproofing materials and construction methods have been developed and applied to various construction sites since the past. However, there many cases where the waterproofing performance is not satisfactory, leading to continuous water leakage. It has been observed that a key reason for this is because waterproofing method and material selection is not optimized in terms of the appropriate application area and environmental degradation factors. This paper proposes that future selection of waterproofing methods should consider the following evaluation criteria; 1) waterproof performance evaluation according to site conditions, 2) evaluation of construction method, 3) manufacturing and maintenance of waterproofing systems.

  • PDF

A Study on the New Criteria for Assessing the Insulation Deterioration of Generator Stator Winding (발전기 고정자 권선의 새로운 절연열화 판정기준 설정에 관한 연구)

  • Hwang, D.H.;Kim, Y.J.;Kim, J.B.;Jeon, J.W.;Kim, H.G.;Park, J.J.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1692-1695
    • /
    • 1997
  • This paper describes the relationship between the various non-destructive parameters and the breakdown voltage for the 17 kV, 300 MVA and the 22 kV, 500 MVA generators stator bars with polyester and epoxy/mica insulation respectively. Also, this study reports the results of an investigation into the factors which can assess the insulation condition of generator stator winding. Furthermore, a new parameter, Partial Discharge Index(PDI), is introduced as the valuable parameter for the assessment of insulation condition. The ratio between partial discharge increment and the stepwise voltage increment from the Discharge Inception Voltage (DIV) at the characteristic or resonant frequency band shows the close relationship between the breakdown voltage and PDI.

  • PDF

Surface Discharge and Materials Analysis of Polymer Insulators Due to Accelerated Deterioration (가속열화에 의한 폴리머애자의 연면방전과 재료분석)

  • Shong, Kil-Mok;Kim, Jong-Min;Jung, Jin-Su;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1372-1373
    • /
    • 2008
  • This study investigated the detection of corona discharge on polymer insulators at 13.2kV. Also, It will be analyzed by variety analyzers such as FT-IR, TA, and so on. It carried out an experiment and an actual measurement about corona detection using a UV-camera. This experiment and inspection would need to respect the above criteria. It was required to verify various experimental conditions and on-site inspection afterwards, but it was believed to minimize the measurement error by data-basing research results in a continuous manner and it was necessary to establish diagnosis technologies and standards in various electrical power facilities.

  • PDF

Feasibility Study on the Introduction of No Net Loss of Green (녹지총량제의 국외사례 및 국내 적용가능성)

  • Choi, Jaeyong;Lee, Dong-Kun;Kim, Eun-Young;Choi, In-Tae
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.2
    • /
    • pp.104-113
    • /
    • 2008
  • Due to the increasing needs of land supply, green space has been continuously encroached and resulted considerable naturality deterioration in Korea. In order to overcome the problem, it is necessary to introduce a integrated system for managing the quantitative and qualitative aspects of green space. With this regard, this study is to derive the feasibility for the adoption of the 'no net loss of green' policy to Korea from German and Japanese experiences. In Germany, natural resources are protected and inevitable damages were compensated through the adoption of 'interference regulation'. In Japanese case, future green space and artificial green foundation should be specified on the green basic plan which pursuit the improvement of naturality. In order to introduce the 'no net loss of green' policy to Korea, not only awareness raising on integrated green management system but also amendment of related regulations are needed. In detail, restoration and recovery on the damaged nature should be clearly elucidated and indicators to evaluate the current naturality and calculation methods for the restoration should be developed. Should this integrated green management system introduced, deterioration of naturality by development activities could be minimized thorough the adoption of land development permission criteria and green space management methodologies.

Inelastic and Local Buckling Behavior of H-Beams with Web Opening under Cyclic Loadings (반복하중을 받는 H형강 유공보의 소성 및 국부좌굴 거동)

  • Lee, Eun Taek;Kim, Cheol Hwan;Oh, Woo Hun
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.3
    • /
    • pp.271-279
    • /
    • 2003
  • Many researches have been conducted to describe the elastic and inelastic behavior of H-shaped beams with web openings, and were generally concentrated on the uniaxial loading conditions. With previous research results, the formulae for the design of beams with web openings, considering local buckling, have been proposed by Darwin. Although the formulae are so simple and useful to apply to real situations, it needs more research on cyclic loading conditions. In this experimental study, a total of seven H-shaped beams with circular web openings under cyclic loading conditions were investigated. The dimension criteria were based on the formulae proposed by Darwin. The suitability of the existing design formulae, the effects of plastic hinges on beams with web openings, and the local bucking around the web openings to the beam strength under cyclic loading were also investigated through by the observations of the behavior of these beams with various dimensional openings.

Development of Deterioration Prediction Model and Reliability Model for the Cyclic Freeze-Thaw of Concrete Structures (콘크리트구조물의 반복적 동결융해에 대한 수치 해석적 열화 예측 및 신뢰성 모델 개발)

  • Cho, Tae-Jun;Kim, Lee-Hyeon;Cho, Hyo-Nam
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.13-22
    • /
    • 2008
  • The initiation and growth processes of cyclic ice body in porous systems are affected by the thermo-physical and mass transport properties, as well as gradients of temperature and chemical potentials. Furthermore, the diffusivity of deicing chemicals shows significantly higher value under cyclic freeze-thaw conditions. Consequently, the disintegration of concrete structures is aggravated at marine environments, higher altitudes, and northern areas. However, the properties of cyclic freeze-thaw with crack growth and the deterioration by the accumulated damages are hard to identify in tests. In order to predict the accumulated damages by cyclic freeze-thaw, a regression analysis by the response surface method (RSM) is used. The important parameters for cyclic freeze-thawdeterioration of concrete structures, such as water to cement ratio, entrained air pores, and the number of cycles of freezing and thawing, are used to compose the limit state function. The regression equation fitted to the important deterioration criteria, such as accumulated plastic deformation, relative dynamic modulus, or equivalent plastic deformations, were used as the probabilistic evaluations of performance for the degraded structural resistance. The predicted results of relative dynamic modulus and residual strains after 300 cycles of freeze-thaw show very good agreements with the experimental results. The RSM result can be used to predict the probability of occurrence for designer specified critical values. Therefore, it is possible to evaluate the life cycle management of concrete structures considering the accumulated damages due to the cyclic freeze-thaw using the proposed prediction method.

Heat Transfer Characteristics of CO2 at Supercritical Pressure in a Vertical Circular Tube (수직원형관에서 초임계압 CO2의 열전달 특성)

  • Yoo, Tae-Ho;Bae, Yoon-Yong;Kim, Hwan-Yeol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.23-31
    • /
    • 2011
  • At supercritical pressure, the physical properties of fluid change substantially and the heat transfer at a temperature similar to the critical or pseudo-critical temperature improves considerably; however, the heat transfer may deteriorate due to a sudden increase in the wall temperature at a certain condition of a mass and heat flux. In this study, the heat transfer rates in $CO_2$ flowing vertically upward and downward in a circular tube with a diameter of 4.57 mm under various conditions were calculated by measuring the temperature of the outer wall of the tube. The published heat transfer correlations were analyzed by comparing their prediction values with 7,250 experimental data. By introducing a buoyancy parameter, a heat transfer correlation, which could be applied only to a normal heat transfer regime, was extended such that it can be applied to regime of heat transfer deterioration. The published criteria for heat transfer deterioration were evaluated against the conditions obtained from the experiment in this study.

A study on the supplementation of the Biotop Area Ratio by case study of Outdoor Environmental Planning Indicators (외부공간 환경계획지표 사례분석을 통한 생태면적률 공간유형 보완 방향 도출 연구 - 식재부문 공간유형 신설을 통한 보완방향을 중심으로 -)

  • Jang, Dae-hee;Kim, Hyeon-soo;Kim, Tae Han
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.3-10
    • /
    • 2012
  • Recently, the increase of impervious area has been pointed out as a major cause of climate change and biotop area deterioration]. Therefore, quantitative indicators for environmental housing design and planning have been needed especially to control the impervious area. The Biotop Area Ratio(BAR) as the mostly applied environmental planning control instrument in Korea verifying the possibility of utilizing has been used effectively in various aspects. However, the fact that the space types are based on two dimension and ecological functions of spaces are simplified has shown the limitations of this planning instrument in the use as planning and evaluation indicator. In this study, classification criteria and the weighting of the space types in similar indicators Biotopflaechenfaktor (BFF, Berlin), Seattle Green Factor (SGF, Seattle), and Green Area Factor (GAF, Malmo) were analyzed. These indicators are similar in the sense that they apply weights to calculate the area and express a percentage of land area. The findings are as follows: The basic method that can estimate the vegetation volume is proposed to overcome the limitation of the BAR. It also was proven that the introduction of three-dimensional volume rate of biotops area was possible. Finally, the framework of space type classification criteria is proposed through linkages with relevant laws and regulations. With the improvement of the space types, the BAR is expected to be reasonable indicator in outdoor space evaluation in housing project.

A Study on Preventive Diagnosis of the Pole Transformer by Gas Analysis -Measurement of Aging of Insulating Oil by UV-Visible Spectrophotometric Method- (개스분석에 의한 주상변압기의 예방진단에 관한 연구 -자외-가시선 흡수분광광도법에 의한 절연유의 열화도 측정-)

  • 곽희로;남영우;윤영자;남궁미옥;이동준
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.5
    • /
    • pp.94-100
    • /
    • 1996
  • Criteria for insulating oil condition of pole transformer were suggested by applying the UV-Visible spectrophotometric method. Aging of insulating oil caused the change in absorbances of oil as well as the deterioration of electrical properties of oil. By comparing the electrical properties such as tan$\delta$ and dielectric breakdown voltage with the UV-Visible absorbances of oil, following criteria for absorbance values determining oil condition were established, fair condition is below 0.580, need attention is 0.580-0.900 and poor condition is above 0.900. This W-Visible spectrophotometric method may be applied in aging analysis of oil and expected to replace the current visual method. It is necessary to develop cheap, light and portable UV-Visible spectrophotometer in near future for field application.

  • PDF

Study on the Evaluation Criteria of Environment Assessment for the Various Type of Small-Scale Development Projects in the Riparian Areas (수변지역 소규모 개발사업의 유형별 환경평가 기준에 관한 연구)

  • Joo, Yong-Joon;Sagong, Hee
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.218-225
    • /
    • 2016
  • Various strategies and management plans have been established in order to conserve water quality as well as ecosystem, prevent deterioration of scenic area, and more importantly, retain drinking water securely. However, due to the introduction of numerous small-scale development projects on the waterside area outside protection area of source water and reparian area, river water quality and landscape are severely deteriorated. In this study, We analyzed the expected environmental impacts on the ecosystem, topograph, geology, landscape, water quality according to development type, and assigned different environmental points to each development type depend on environmental impacts, which is able to divide small-scale development project into three categories such as projects with rigorous review, projects with general review and projects with simple review. Finally, we suggested the appraisal basement is to avoid or minimize the expected environment impacts of the small-scale development projects in riparian areas so that make them sustainable development by reasonable restriction.