• 제목/요약/키워드: criteria of deterioration

검색결과 154건 처리시간 0.029초

접착식 콘크리트 덧씌우기의 부착강도 특성 분석 (Bond Strength Characteristics of Bonded Concrete Overlay)

  • 박종원;김영규;이승우;한승환
    • 한국도로학회논문집
    • /
    • 제15권4호
    • /
    • pp.1-9
    • /
    • 2013
  • PURPOSES : Bonded concrete overlay is a favorable maintenance method since the material properties are similar to existing concrete pavements. In addition, bonded concrete overlay has advantage of structural performance since the overlay layer and the existing pavement perform as a monolithic layer. It is important to have suitable bond strength criteria to secure the performance of bonded concrete overlay. This study aimed to investigate the factors influencing bond strength characteristics between existing concrete pavement and overlay material. METHODS: Bond strength between overlay and existing pavement are measured and analyzed for various conditions such as the type of overlay materials, compressive and flexure strength of overlay and existing pavement, and deterioration status of existing pavement. RESULTS: The strength of overlay material does not significantly influence the bond strength. The overlay of ultra-rapid hardening cement generally gives low bond strength. However, ultra rapid hardening polymer modified concrete gives robust bond strength. The deterioration of existing concrete significantly decrease the bond strength. CONCLUSIONS: Bond strength of bonded concrete overlay highly depends on condition of existing concrete pavement rather than overlay material.

Utopian Approach를 이용한 상수관망 개별관로 개량우선순위 산정에 관한 연구 (Study of Rehabilitation Priority Order of Pipes for Water Distribution Systems using Utopian Approach)

  • 유도근;전환돈;김중훈
    • 상하수도학회지
    • /
    • 제24권2호
    • /
    • pp.183-193
    • /
    • 2010
  • Well planned rehabilitation order of pipes is essential for efficient maintenance and management of Water Distribution Systems. In this study, not only deterioration rate of pipes but also structural and nonstructural failure which causes abnormal condition of WDS is considered to determine rehabilitation order. Probabilistic Neural Network is used for calculating deterioration rate at present and the importance of pipes is computed under structural and nonstructural failure by using Pipe by Pipe Failure Analysis and Effect Index. Utopian Approach, one of the Multi-Criteria Decision Making methods, is used for assessment of final rehabilitation order based on distance measure between utopian point and alternative one. Developed model in this study shows that it gives more reliable results than existing methods considering hydraulic relative importance does in application to real networks. In this point, the newly developed model, which gives advantages over existing models, can make a credible decision and simple application.

신뢰성 방법에 기초한 기설 P.C교의 안전도 및 내하력 평가 (Safety Assessment and Capacity Rating of Existing P.C, Bridges based on Reliability Methods)

  • 조효남;김민영;서종원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 가을 학술발표회 논문집
    • /
    • pp.45-50
    • /
    • 1990
  • This study develops practical models and methods for the assessment of safety and capacity rating of existing P.C. girder bridges based on the reliability methods. One of the main objectives of the study is to propose a practical but realistic limit state model for safety assessment and LRFR rating criteria, which explicitly incorporates the degree of deterioration and damage as well as actual condition of P.C. girder bridges in terms of the damage factor and the response ratio. The damage factor proposed in the paper is defined as the ratio of the current estimated stiffness to the intact base-line stiffness of a member. Based on the observation and the results of applications to existing bridges, it may be concluded that the proposed methods for the assessment and capacity rating models, which explicitly account for the uncertainties and effects of degree of deterioration or damage, provide more realistic and consistent safety-assessment and capacity rating.

  • PDF

지하 콘크리트 구조물 조인트에 대한 멤브레인 방수시스템의 복합 환경 대응 성능 평가 방법 (Complex Environmental Degradation Resistance Performance Evaluation Method of Membrane Waterproofing Systems for Underground Concrete Structure Joint)

  • 오규환;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.44-45
    • /
    • 2017
  • There are various national standards designed to test the physical properties of waterproofing materials for the respective countries based on each of their environmental parameters, variables and requirements. The problems of these standard systems can be outlined in the following: (1) there are too many test methods and criteria to satisfy in order assess one waterproofing membrane system, and (2) there is currently no known method to compile the separate testing results to provide a comprehensive report on waterproofing system durability. This paper outlines and compares the performance testing results of various types of asphalt waterproofing membrane systems and discusses the potentials of a complex environmental deterioration analysis method.

  • PDF

전력용 변압기 예방진단새스템의 진단기준치 실정 (Establishment of Diagnostic Criteria in the Preventive Diagnostic System for the Power Transformer)

  • 권동진;구교선;곽주식;우정욱;강연욱
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권9호
    • /
    • pp.449-456
    • /
    • 2005
  • The preventive diagnostic technique prevents transformers from power failure through giving alarm and observing transformers in service. And it helps to establish the plan for optimum maintenance of the transformer as well as to find location or cause of fault using accumulated data. Data detection and experience of the preventive diagnostic system need to establish the preventive diagnostic algorithm regarding interrelationship between detected data and deterioration of equipment. Therefore in-depth analysis about the preventive diagnosis system is required. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Techniques for component sensors of the preventive diagnosis system were settled but diagnosis algorithm, diagnostic criteria and practical use of accumulated data are not yet established. This paper, to build up the base of preventive diagnostic algorithm for the Power transformer. investigated the preventive diagnostic criteria for the power transformer.

Post-Laminectomy Kyphosis in Patients with Cervical Ossification of the Posterior Longitudinal Ligament : Does It Cause Neurological Deterioration?

  • Cho, Won-Sang;Chung, Chun-Kee;Jahng, Tae-Ahn;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권6호
    • /
    • pp.259-264
    • /
    • 2008
  • Objective : Total laminectomy (TL) is an effective surgical technique for the treatment of cervical ossification of the posterior longitudinal ligament (OPLL) along multiple levels. However, kyphosis and probable neurological deterioration have been frequently reported after laminectomy. We analyzed the changes in the cervical curvature after TL and subsequent changes in neurological status. Methods : We retrospectively reviewed the records of 14 patients who underwent TL for the treatment of cervical OPLL between Jan. 1998 and Dec. 2003. TL was selected according to the previously determined criteria. The curvature of the cervical spine was visualized on a lateral cervical spine X-ray and measured using Ishihara's Curvature Index (CI) before the operation and at the last follow-up examination. Perioperative neurological status was estimated using the modified Japanese Orthopedic Association score and the Improvement Rate (IR) at the same time as the images were evaluated. Results : The mean age of the patients was 57 years, the male/female ratio was 10:4, and the mean follow-up period was 41 months. The mean number of OPLL was 4.9, and the mean number of operated levels was also 4.9. The CI decreased after TL (p=0002), which was indicative of a kyphotic change. However, this kyphotic change showed no correlation with the length of the follow-up period, number of operated levels and preoperative CI. Neurological examination at the last follow-up showed an improved neurological status in all patients (p=0.001). There was no neurological deterioration in any case during the follow-up period. Moreover, there was no correlation between IR and the degree of kyphotic change. Postoperative complications, such as C5 radiculopathy and epidural bleeding, resolved spontaneously without neurological sequelae. Conclusion : Kyphotic change was observed in all but one patient who underwent TL for the treatment of cervical OPLL. However, we did not find any contributing factors to kyphosis or evidence of postoperative neurological deterioration.

백두대간 마루금 선자령순환등산로의 숲길훼손실태 연구 (A Study on the Deterioration Status of the Seonjaryeong Forest Trails in the Baekdudaegan Ridge)

  • 이수광;이진규;김명준;방홍석
    • 한국산림과학회지
    • /
    • 제110권1호
    • /
    • pp.91-105
    • /
    • 2021
  • 본 연구는 백두대간 마루금 선자령순환등산로 4.3 km에서 정성적으로 평가되는 훼손등급을 적용하여 숲길훼손이 발생된 구역의 구체적인 데이터와 조사방법을 제시하고, 조사항목간의 관계를 구명하고자 수행되었다. 그 결과, 선자령순환등산로의 평균 노폭(1.7 m)과 나지폭(1.4 m)은 지금까지 보고된 연구에 비해 매우 넓은 것으로 나타났으며, 훼손비율 또한 높은 것으로 확인되었다. 정성적인 기준으로 평가된 훼손등급에 대해 다음과 같이 구체적인 데이터를 확보할 수 있었다. 훼손등급 강의 경사도는 20.1%, 침식깊이는 평균 13.3 cm, 중앙 16.1 cm, 침식량 16.2 ㎠로 나타났으며 토양경도는 평균 12.3 kg/㎠(20.1 mm), 최대 39.3 kg/㎠(29.6 mm)로 나타났다. 훼손등급과 경사도는 양의 상관관계를 보였고, 능선보다 산복에서 평균과 중앙의 토양침식깊이가 깊어지는 것으로 나타났다. 그리고 토양경도는 횡단 측정위치와 방법에서 유의적인 차이가 있는 것으로 나타났다. 따라서 선자령순환등산로는 경사도가 20% 이상인 구간에서 훼손이 발생함에 따라 지속 가능한 이용을 위해서는 고정조사점에서의 지속적인 모니터링이 필요하다. 또한, 숲길설계와 관리에는 경사도가 우선적으로 고려되어야 한다.

전력(電力)케이블 열화진단(劣化診斷) 기술(技術)의 동향(動向) (THE TREND OF DIAGNOSTIC METHODS FOR POWER CABLE)

  • 한기만;김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.779-783
    • /
    • 1992
  • In recent years, it is strongly required to supply high quality electrical power without insulation failure in distribution power cables. Therefore the exact measurement and judgment ar out deterioration degree of cables are essential to increase that supplying reliability. This paper will introduce various diagnostic methods of off-line and live-line cables also propose the judgement criteria and newly trend of diagnostic technique at present.

  • PDF

흡광도법에 의한 주상변압기 절연유의 열화판정기준 설정에 관한 연구 (A Study on Suggestion of Insulating Oil Ageing Degree in Pole-Transformer by Absorbance)

  • 이동준;정종욱;김경화;곽희로;윤영자
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1851-1853
    • /
    • 1996
  • In this paper the criteria for insulating oil condition of pole transformer were suggested by applying the UV-Visible spectrophotometric method. Ageing of insulating oil caused the change in absorbances of oil os well os the deterioration of electrical properties of oil. By comparing the electrical properties such as $tan{\delta}$ and breakdown voltage with the UV-Visible absorbances of oil, criteria for absorbance values determining oil condition were established. This UV-Visible spectrophotometric method might be applied in ageing analysis of oil and be expected to replace the current method.

  • PDF

도서관장서의 폐기기준에 관한 고찰 (A Study on Welding Criteria of Library Collections)

  • 이은철
    • 한국도서관정보학회지
    • /
    • 제9권
    • /
    • pp.213-240
    • /
    • 1982
  • Today, one of the major pressures that libraries have been facing is the rapid growth of publications. Due to the rapid growth of publications, libraries have been faced the shortage of stack as well as quality deterioration of library collections. Naturally, these disa n.0, ppointed the users and made the present library activities weak and inadequate. One of the desirable actions in remedying these problems is to weed library collections properly and regularly. Weeding methods used in libraries are derived from the judgement by subject specialists, from the examining the imprint date and the past use patterns of a volume. Among these methods, the past use patterns are highly predictive of the future use, and can be used to create meaningful weeding criteria. Since the libraries in Korea have emphasized on numbers of library collection in the past, the libraries have neglected weeding library collections. Now, we must turn our concern toward the weeding library collections, and the attitude of the library services to the users must change from passive to active.

  • PDF