• 제목/요약/키워드: creep testing

검색결과 108건 처리시간 0.022초

AISI 316L스테인리스강의 소형펀치 크리프 거동에 미치는 마찰계수의 영향 (Effect of Friction Coefficient on the Small Punch Creep Behavior of AISI 316L Stainless Steel)

  • 김범준;조남혁;김문기;임병수
    • 대한금속재료학회지
    • /
    • 제49권7호
    • /
    • pp.515-521
    • /
    • 2011
  • Small punch creep testing has received attention due to the convenience of using smaller specimens than those of conventional uniaxial creep tests, which enables creep testing on developing or currently operational components. However, precedent studies have shown that it is necessary to consider friction between the punch and specimen when computing uniaxial equivalent stress from a finite element model. In this study, small punch creep behaviors of AISI 316L stainless steel, which is widely used in high temperature-high pressure machineries, have been compared for the two different ceramic balls such as $Si_3N_4$ and $Al_2O_3$. The optimal range of the friction coefficient is 0.4~0.5 at $650^{\circ}C$ for the best fit between experimental and simulation data of AISI 316 L stainless steel. The higher the friction coefficient, the longer the creep rupture time is. Therefore, the type of ceramic ball used must be specified for standardization of small punch creep testing.

HK-40 고온반응관 용접부의 Creep손상 진단기법 및 자동 초음파탐상장치의 개발에 관한 연구 (A Study on the Development of Ultrasonic Scanning Device for the Inspection and Evaluation of Creep Damage of HK - 40 Reformer Tube Welded Zone)

  • 조경식
    • 비파괴검사학회지
    • /
    • 제9권1호
    • /
    • pp.98-105
    • /
    • 1989
  • Detection of creep damages in centrifugally cast HK-40 reformer furnace catalyst tube is a common problem for the safety and scheduled operation of chemical plants. This study was focused on the development of an automatic ultrasonic scanning device with which the creep damage of welded zone of HK-40 reformer tubes is detected and evaluated.

  • PDF

Creep Lifetime Prediction of Composite Geogrids using Stepped Isothermal Method

  • Koo, Hyun-Jin;Cho, Hang-Won
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2006년도 학술발표대회 논문집
    • /
    • pp.158-164
    • /
    • 2006
  • The creep behavior of newly developed composite geogrids which consists of PET yarns sheathed in PP were evaluated using SIM. For the SIM procedure, three test parameters, the applied loads, temperature steps and number of ribs were investigated, The study confirmed that temperature steps of 10 and 14$^{\circ}C$ up to 80$^{\circ}C$ are applicable for composite geogrids due to the different transition temperatures between two materials. At applied loads of 40 and 50%, only primary creep state was measured, while secondary creep state appeared at the applied loads of 60%, The lifetimes of composite geogrids were estimated at each of loading level using statistical reliability analysis technique. The results show that the lifetimes longer than 100 years can be predicted within 16 hours. Therefore, SIM is very effective and economical accelerated creep test methods, especially for lifetime prediction. This gives guidelines for users to select the appropriate factor of safety against creep considering the field condition within shorter test times.

  • PDF

Investigating creep behavior of Ni-Cr-W alloy pressurized tube at 950 ℃ by using in-situ creep testing system

  • Zhong, Yang;Lan, Kuan-Che;Lee, Hoon;Zhou, Bomou;Wang, Yong;Tsang, D.K.L.;Stubbins, James F.
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1481-1485
    • /
    • 2020
  • The creep behavior of Ni-Cr-W alloy at 950 ℃ has been investigated by a novel creep testing system which is capable of in-situ measurement of strain. Tubular specimens were pressurized with argon gas for effective stresses up to 32 MPa. Experimental results show that the thermal fatigue reduces the creep life of the tubular specimens and with the introduction of thermal cycling fatigue the primary stage disappears and the creep rate higher than the pure thermal creep (without thermal fatigue). Also the creep behavior of Ni-Cr-W alloy doesn't consist in the secondary stage. A new creep equation has been derived and implemented into finite element method. The results from the finite element analyses are in good agreement with the creep experiment.

발전소 고온부의 수명 평가를 위한 소형 시편용 크리프 시험기의 개발 (Development of Small-Specimen Creep Tester for Life Assessment of High Temperature Components of Power Plant)

  • 김효진;정용근;박종진
    • 대한기계학회논문집A
    • /
    • 제24권10호
    • /
    • pp.2597-2602
    • /
    • 2000
  • The most effective means of evaluating remaining life is through the creep testing of samples removed from the component. But sampling of large specimen from in-service component is actually impossible. So, sampling device and small-specimen creep tester have been applied. Sampling device has been devised to extract mechanically small samples by hemispherical, diamond -coated cutter from the surface of turbine rotor bores and thick-walled pipes without subsequent weld repairs requiring post weld heat treatment. A method of manufacturing small creep specimen, 2min gage diameter and 10min gage length, using electron beam welding to attach grip section, has been proven. Small-specimen creep tester has been designed to control atmosphere to prevent stress increment by oxidation during experiment. To determine whether the small specimens successfully reproduce the behavior of large specimens, creep rupture tests for small and large specimens have been performed at identical conditions. Creep rupture times based on small specimens have closely agreed within 5% error compared with that of large specimen. The errors in rupture time have decreased at longer test period. This comparison validates the procedure for fabricating and testing on small specimen. This technique offers potential as an efficient method for remaining life assessment by direct sampling from in -service high temperature components.

초음파 Spectrum 해석에 의한 Creep 손상재의 비파괴평가 (Nondestructive Evaluation of Creep Damage Materials by using Ultrasonic Spectrum Analysis)

  • 김창일;이원;임영호
    • 비파괴검사학회지
    • /
    • 제11권2호
    • /
    • pp.42-47
    • /
    • 1991
  • Nondestructive evaluation study was made on creep damage materials by ultrasonic spectrum analysis. The evaluation methods was developed in order to predict the change of ultrasonic attenuation with increasing creep damage. A new algorithm for the improvement of measuring accuracy of ultrasonic attenuation using a spectrum analysis has been developed. Normally, the ultrasonic attenuation is evaluated from 1st and 2nd peak values of the pulse-echo ultrasonic wave. The algorithm developed is incorporated in a measuring system which consists of a personal computer with ultrasonic apparatus and a digital storage oscilloscope. By the spectrum analysis method, it become popssible to describe approximately the attenuation change with increassing creep damage in Cr-Mo-V forging.

  • PDF

박판 스프링용 탄소공구강재(SK4M)의 시험온도에 따른 기계적 특성 (The Effects of the Testing Temperatures on the Mechanical Properties of the Carbon Tool Steel(SK4M) for Flat Spring)

  • 류태호;원시태;박상언;임철록
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.693-696
    • /
    • 2002
  • This study examined the effects of the testing temperature on the mechanical properties of the carbon tool steel (SK4M) for flat spring. Hardness test and fatigue test were performed at room temperature ($20^{\circ}C$). Tensile test and creep test were performed at temperature range $20^{\circ}C$ ~$160^{\circ}C$. The micro-vickers hardness values of SK4M was Hv=584. The Elastic modulus, tensile strength and yield strength of SK4M at 160t test temperature were decreased 0.92 time, 0.97 time and 0.82 time those of SK4M at 2$0^{\circ}C$ test temperature, respectively. The maximum creep strain for 100hr at creep temperature ($80^{\circ}C$ ~$160^{\circ}C$) and creep stress ($37.4Kgf/\textrm{mm}^2$ ~$93.6Kgf/\textrm{mm}^2$) was 0.572%. The fatigue limit of SK4M was $94Kgf/\textrm{mm}^2$.

  • PDF

W치환 2205 이상 스테인리스강의 크리프 특성 평가에 관한 연구 (Evaluation of Creep Properties of W-substituted 2205 Duplex Stainless Steel)

  • 김기엽;최병호;남기우;안용식
    • 비파괴검사학회지
    • /
    • 제24권1호
    • /
    • pp.29-37
    • /
    • 2004
  • 22Cr-5Ni 2상 스테인리스강의 합금원소 중 몰리브덴(Mo) 원소를 텅스텐(W)으로 치환하여 크리프거동에 미치는 영향을 조사하였다. 그리프시험은 $600^{\circ}C$$650^{\circ}C$의 온도에서 실시하였다. $650^{\circ}C$ 크리프 시에는 취약한 금속간화합물인 ${\sigma}$상이 석출하였으며 이것은 크리프수명을 급격히 감소시키는 역할을 하였다. Mo에 대한 W원소의 치환은 일반적으로 ${\sigma}$상의 석출을 지연시킨다고 알려져 있으나, 2wt.%까지 W 치환을 실시한 본 연구범위에서는 크리프 수명 및 최소 크리프속도에 뚜렷한 영향을 미치지 못하였다. 크리프손상의 정도를 평가하기 위하여 크리프시편에 대한 초음파검사를 실시하였다 크리프온도 $600^{\circ}C$에서는 크리프시편의 수명이 증가함에 따라 음속이 비례적으로 증가하였으나 $650^{\circ}C$에서는 반대로 감소하였다.

구속수축에 의한 콘크리트 인장크리프 특성 (Tensile Creep Properties of Concrete under Restrained Shrinkage)

  • 최훈제;서태석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.28-29
    • /
    • 2016
  • By Testing restrained shrinkage, it is possible to estimating the cracking tendency of concrete such as time to cracking, tensile stress and tensile creep. In this study, tensile creep properties of concrete under restraint shrinkage were investigation through comparison of specimens that JIS and AASHTO proposed. As a results, tensile creep strains in concrete ring specimens were 15% higher than those in uniaxial specimens.

  • PDF

Mechanical Properties of Refractory Metals at Extremly High Temperatures

  • Fischer, B.;Beschliesser, M.;Hoffmann, A.;Vorberg, S.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.946-947
    • /
    • 2006
  • Driven by the unavailibility of commercial test equipment for tensile and creep testing at temperatures up to $3000^{\circ}C$ a measuring system has been developed and constructed at the University of Applied Sciences, Jena. These temperatures are reached with precision by heating samples directly by electric current. Contact-less strain measurements are carried out with image processing software utilizing a CCD camera system. This paper covers results of creep tests which have been conducted on TZM sheet material (thickness 2 mm) in different heat-treatment conditions in the temperature range between $1200^{\circ}C$ and $1600^{\circ}C$.

  • PDF