• Title/Summary/Keyword: couplings

Search Result 236, Processing Time 0.025 seconds

Finite Element Analysis for Acoustic Characteristics of Piezoelectric Underwater Acoustic Sensors (압전 수중음향센서 음향특성의 유한요소해석)

  • 김재환;손선봉;조철희;조치영
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.68-76
    • /
    • 2001
  • Sonar is the system that detects objects and finds their location in water by using the echo ranging technique. In order to have excellent performance in variable environment, acoustic characteristics of this system must be analyzed accurately. In this paper, based on the finite element analysis, modeling and analysis of acoustic characteristics of underwater acoustic sensors are preformed. Couplings between piezoelectric and elastic materials, and fluid and structure systems associated with the modeling of piezoelectric underwater acoustic sensors are formulated. In the finite element modeling of unbounded acoustic fluid, IWEE (Infinite Eave Envelop Element) is adopted to take into account the infinite domain. When an incidence wave excites the surface of Tonpilz underwater acoustic sensor, the scattered wave on the sensor is founded by satisfying the radiation condition at the artificial boundary approximately. Based on this scattering analysis, the electrical response of the underwater acoustic sensor under incidence, so called RVS (Receiving Voltage Signal) is founded accurately. This will devote to design Sonar systems accurately.

  • PDF

An Analysis of Inelastic Neutron Scattering by Liquid Methane

  • Chung, Chang-Hyun;Shin, Won-Kee;Kim, Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.265-278
    • /
    • 1973
  • The incoherent neutron scattering cross section of molecular liquids is analyzed using a damping function model for correlation functions of molecular translations and rotations. The present approach is different from recent works in that the scattering function is evaluated directly, not through the intermediate scattering function. The damping fuction is determined from a simple relation between its long-wavelength limit and the generalized frequency distribution function, and translation-rotation couplings are assumed to be neglected. A physical model is used for the translational motions of center-of-mass of a molecule, including properly its short-time and long-time behaviors. A simple model for the rotational motions is suggested which relates the damping function to the Fourier transform of the dipole correlation function, or equivalently, the infrared vibrational absorption spectrum. Theoretical absolute scattering intensities are computed for liquid methane and shown to be in satisfactory agreement with both thermal and cold neutron measurements.

  • PDF

Accuracy of a direct estimation method for equivalent material properties of 1-3 piezocomposites (1-3형 압전복합재료 등가물성 직접 추출 기법의 정확도 분석)

  • Eunghwy Noh;Donghyeon Kim;Hyeongmin Mun;Woosuk Chang;Hongwoo Yoon;Seonghun Pyo;Kyungseop Kim;Yo-Han Cho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.377-387
    • /
    • 2023
  • This paper presents accuracy of a method that directly estimates equivalent properties of a 1-3 piezocomposite for modeling it into the single phase homogeneous piezomaterial. This direct estimation method finds individual components of a material property matrix based on the piezoelectric constitutive equations, which represent mechanical and electrical behaviors and their couplings. Equivalent properties on a single 1-3 piezocomposite hydrophone are derived, and their accuracy depending on pairing of the constitutive equations is investigated by comparing them with finite element analysis for the whole domain. The accuracy is related to elastic characteristics of a matrix polymer, and the error is analyzed so that some guidelines for correct estimation are suggested. Fidelity of estimated properties and equivalent modeling is shown in a stave scale including hydrophones and surrounding acoustic structures as well, and reduced computational cost is verified.

Understanding Physical Mechanism of 2022 European Heat Wave (2022년 발생한 기록적인 유럽 폭염 발생의 역학적 원인 규명 연구)

  • Ju Heon Kim;Gun-Hwan Yang;Hyun-Joon Sung;Jung Hyun Park;Eunkyo Seo
    • Atmosphere
    • /
    • v.33 no.3
    • /
    • pp.307-317
    • /
    • 2023
  • This study investigates the physical mechanisms that contributed to the 2022 European record-breaking heatwave throughout May-August (MJJA). The European climate has experienced surface warming and drying in the recent decade (1979~2022) which influences the development of the 2022 European heatwave. Since its spatial pattern resembles the 2003 European heatwave which is a well-known case developed by the strong coupling of near-surface conditions to land surface processes, the 2022 heatwave is compared with the 2003 case. Understanding heatwave development is carried out by the European Centre for Medium-Range Weather Forecasts (ECMWF) Reanalysis version 5 (ERA5) and daily maximum surface temperature released by NCEP (National Centers for Environmental Prediction) CPC (Climate Prediction Center). The results suggest that the persistent high pressure along with clear sky tends to increase the downward shortwave radiation which leads to enhanced sensible heat flux with the land surface dryness. Terrestrial Coupling Index (TCI), a process-based multivariate metric, is employed to quantitatively measure segmented feedback processes, separately for the land, atmosphere, and two-legged couplings, which appears to the development of the 2022 heatwave, can be viewed as an expression of the recent trends, amplified by internal land-atmosphere interactions.

Differences in the Control of Anticipation Timing Response by Spatio-temporal Constraints

  • Seok-Hwan LEE;Sangbum PARK
    • Journal of Sport and Applied Science
    • /
    • v.7 no.2
    • /
    • pp.39-51
    • /
    • 2023
  • Purpose: The purpose of this study was to investigate differences in the control process to satisfy spatial and temporal constraints imposed upon the anticipation timing response by analyzing the effect of spatio-temporal accuracy demands on eye movements, response accuracy, and the coupling of eye and hand movements. Research design, data, and methodology: 12 right-handed male subjects participated in the experiment and performed anticipation timing responses toward a stimulus moving at three velocities (0.53m/s, 0.66m/s, 0.88m/s) in two task constraint conditions (temporal constraint, spatial constraint). During the response, response accuracy and eye movement patterns were measured from which timing and radial errors, the latency of saccade, fixation duration of the point of gaze (POG), distance between the POG and stimulus, and spatio-temporal coupling of the POG and hand were calculated. Results: The timing and radial errors increased with increasing stimulus velocity, and the spatio-temporal constraints led to larger timing errors than the temporal constraints. The latency of saccade and the temporal coupling of eye and hand decreased with increasing stimulus velocity and were shorter and longer respectively in the spatio-temporal constraint condition than in the temporal constraint condition. The fixation duration of the POG also decreased with increasing stimulus velocity, but no difference was shown between task constraint conditions. The distance between the POG and stimulus increased with increasing stimulus velocity and was longer in the temporal constraint condition compared to the spatio-temporal constraint condition. The spatial coupling of eye and hand was larger with the velocity 0.88m/s than those in other velocity conditions. Conclusions: These results suggest that differences in eye movement patterns and spatio-temporal couplings of stimulus, eye and hand by task constraints are closely related with the accuracy of anticipation timing responses, and the spatial constraints imposed may decrease the temporal accuracy of response by increasing the complexity of perception-action coupling.

Assessment of cold-formed steel screwed beam-column conections: Experimental tests and numerical simulations

  • Merve Sagiroglu Maali;Mahyar Maali;Zhiyuan Fang;Krishanu Roy
    • Steel and Composite Structures
    • /
    • v.50 no.5
    • /
    • pp.515-529
    • /
    • 2024
  • Cold-formed steel (CFS) is a popular choice for construction due to its low cost, durability, sustainability, resistance to high environmental and seismic pressures, and ease of installation. The beam-column connections in residential and medium-rise structures are formed using self-drilling screws that connect two CFS channel sections and a gusset plate. In order to increase the moment capacity of these CFS screwed beam-column connections, stiffeners are often placed on the web area of each single channel. However, there is limited literature on studying the effects of stiffeners on the moment capacity of CFS screwed beam-column connections. Hence, this paper proposes a new test approach for determining the moment capacity of CFS screwed beam-column couplings. This study describes an experimental test programme consisting of eight novel experimental tests. The effect of stiffeners, beam thickness, and gusset plate thickness on the structural behaviour of CFS screwed beam-column connections is investigated. Besides, nonlinear elasto-plastic finite element (FE) models were developed and validated against experimental test data. It found that there was reasonable agreement in terms of moment capacity and failure mode prediction. From the experimental and numerical investigation, it found that the increase in gusset plate or beam thickness and the use of stiffeners have no significant effect on the structural behaviour, moment capacity, or rotational capacity of joints exhibiting the same collapse behaviour; however, the capacity or energy absorption capacities have increased in joints whose failure behaviour varies with increasing thickness or using stiffeners. Besides, the thickness change has little impact on the initial stiffness.

V-band CPW 3-dB Directional Coupler using Tandem Structure (Tandem구조를 이용한 V-band용 CPW 3-dB 방향성 결합기)

  • Moon Sung-Woon;Han Min;Baek Tae-Jong;Kim Sam-Dong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.7 s.337
    • /
    • pp.41-48
    • /
    • 2005
  • We design and fabricate 3-dB tandem directional coupler using the coplanar waveguide structure which is applicable to balanced amplifiers and mixers for 60 GHz wireless local area network system. The coupler comprises the multiple-sectional parallel-coupled lines to facilitate the fabrication process, and enable smaller device size and higher directivity than those of the conventional 3-dB coupler employing the edge-coupled line. In this study, we adopt the structure of two-sectional parallel-coupled lines of which each single-coupled line has a coupling coefficient of -8.34 dB and airbridge structure to monolithically materialize the uniplanar coupler structure instead of using the conventional multilayer or bonded structure. The airbridge structure also supports to minimize the parasitic components and maintain desirable device performance in V-band (50$\~$75 GHz). The measured results from the fabricated couplers show couplings of 3.S$\~$4 dB and phase differences of 87.5$^{\circ}{\pm}1^{\circ}$ in V-band range and show directivities higher than 30 dB at a frequency of 60 GHz.

An Ergonomic Study on Manual Lifting Tasks in Motor Assembly Processes (자동차 조립 부서 Manual Lifting 작업에 관한 인간공학적 연구)

  • Kwon, Eun-Hye;Paik, Nam-Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.1-23
    • /
    • 1998
  • Work-related Low Back Pain(LBP) is one of tile most important Issues in the field of industrial safety and health. Particularly, manual lifting is known as a major cause of work-related LBP and impairment. Total number of 163 manual lifting tasks in motor assembly processes were investigated. The 1981 and the 1994 equations developed by National Institute for Occupational Safety and Health(NIOSH) were applied to evaluate potential hazards of lifting-related LBP. Comparisons between the 19R I and 1994 NIOSH criteria were made. The relationships between the NIOSH criteria and lifting-related LBP were also analyzed. The results of this study are as follows: 1. The values of Action Limit(AL) by the NIOSH 1981 lifting equation. Recommended Weight Limit(RWL) by the 1994 equation and the weight of the load handled at each manual lifting task were shown log-normal distributions. 2. LI'(the weight of tile load/AL) and LI(the weight of the load/RWL) were calculated estimate the physical stress imposed by each individual lifting task. As a result. 76.7% of the total LI' value exceeded 1 and 12.9% exceeded 3, and 84.7% of the total LI values exceeded 1 and 20.9% exceeded 3. 3. Bus 2 Department showed the highest rate of LI'>1 and LI>1 and Bus 1 Department showed the highest rate of LI'>3 and LI>3 4. In general, the RWLs by the 1994 equation were found lower than the ALs by the 1981 equation. It is assumed to he resulted from the fact that the 1994 equation includes methods evaluating asymmetrical lifting tasks and lifts of objects with less then optimal hand-container couplings, and also covers a larger range of work durations and lifting frequencies than the 1981 equation. 5. Significant correlations were found between LI' and incidence of LBP (R=0.734, p<0.05). LI and incidence of LBP(R=0.671. p<0.10) and load-weights and incidence of LBP(R=0.797, p<0.05). 6. Control measures are required to achieve the value of LI less than 1 for some tasks having high LI values. Engineering control is highly recommended for some tasks having the value of LI above 3.

  • PDF

Changes in Multi-channel Electrogastrography after Acupuncture Treatmet in Patients with Functional Dyspepsia (기능성 소화불량증 환자에서 침구 처치 후 다채널 위전도 소견의 변화)

  • Kim, Yoo-Seung;Ryu, Bong-Ha;Kim, Jin-Sung;Hong, In-A;Park, Young-Sun;Jung, Yong-Jae;Oh, Seung-Whan;Han, Ga-Jin
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.1
    • /
    • pp.152-157
    • /
    • 2010
  • The aim of this study was to investigate the effects of traditional Korean medical therapy in patients with functional dyspepsia evaluted using multi-channel electrogastrography. Before the treatment, the EGG of 14 outpatients (male 3, female 11) with functional dyspepsia were recorded and their dominant frequency(DF), percentage of gastric slow waves, percentage of Power ratio, and percentage of slow wave couplings were analysed. For 8 weeks, the patients received acupuncture treatment. After 8 weeks, EGG was rechecked and compared with the previous data. After treatment, normogastria was significantly increased in channel 1 and channel 3($53.70{\pm}18.94$% vs $72.64{\pm}15.49$% in channel 1, P<0.05; $79.74{\pm}18.09$ vs $90.86{\pm}8.86$ in channel 3, P<0.05). arrythmia was significantly decreased in channel 3($14.34{\pm}15.21$ vs $5.93{\pm}6.90$, P<0.05). The patients who had less severe decrease in EGG indexes showed improvement of those indexes through 8 weeks of outpatient care. EGG channel 3 was shown to be the most adequate standard of evaluation. But there was no significant improvement in slow wave coupling rate which is a new index of multichannel EGG.

Design and Fabrication of Ka-Band NRD Guide Filter with Newly Designed Inductive Post Structure (새로운 유도성 포스트 구조를 갖는 Ka-Band NRD 가이드 필터의 설계 및 제작)

  • 김영수;류원렬;유영근;최재하
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.4
    • /
    • pp.369-376
    • /
    • 2003
  • In this paper, Ka-Band NRD guide band pass filter with newly designed inductive post structure is proposed and analyzed with its test results. Generally, millimeter-wave filters are very sensitive in their physical dimensions, hence, it is requires extreme precisions of several micron so as to get the designed performance. In case of common NRD Guide filter with air gap coupled structure, it is fabricated with dielectric blocks coupled via air gap. In these structures, however, it was not easy to fabricate and to process of each NRD guide dielectric resonator blocks using PTFE, so it was almost impossible to assemble with several microns in precision. In this our research, however, each dielectric resonators are coupled with a pair of inductive metal post, so all resonators are located in a single NRD Guide. The dielectric parts between two pairs of posts are operated as resonators of each stage, and the positions of the post decide the couplings between resonators. The structure we suggested is suitable fur mass production, because it is very simple and easy to process. As a result of measurements, designed NRD guide inductive post filter has a superior performance. The center frequency is 39.475 GHz with 350 MHz bandwidth, insertion loss is less than 1.8 dB, and the return loss is below than -18 dB.