• 제목/요약/키워드: coupling factor

검색결과 761건 처리시간 0.027초

적층 압전초음파모터용 소자의 전기적 특성 (The Electrical properties of piezoelectric device for Multilayer Piezoelectric Ultrasonic Motor)

  • 이갑수;이상호;류주현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.325-326
    • /
    • 2006
  • In this study, in order to develop piezoelectric device for multilayer piezoelectric ultrasonic motor, low temperature sintering $Pb(Mn_{1/3}Nb_{2/3})_{0.02}(Ni_{1/3}Nb_{2/3})_{0.12}(Zr_{0.48}Ti_{0.52})_{0.86}O_3$ system ceramics were fabricated according to the variations of forming pressure of casting sheet. At the 300[$kgf/cm^2$] forming pressure, the maximum density of 7.8[$g/cm^3$] was obtained. At the 350[$kgf/cm^2$] forming pressure, the maximum values of effective electromechanical coupling factor $k_{cff}\;=\;0.24$ and mechanical quality factor Qm=628 were obtained.

  • PDF

A study of the kinematic characteristic of a coupling device between the buffer system and the flexible pipe of a deep-seabed mining system

  • Oh, Jae-Won;Lee, Chang-Ho;Hong, Sup;Bae, Dae-Sung;Cho, Hui-Je;Kim, Hyung-Woo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권3호
    • /
    • pp.652-669
    • /
    • 2014
  • This paper concerns the kinematic characteristics of a coupling device in a deep-seabed mining system. This coupling device connects the buffer system and the flexible pipe. The motion of the buffer system, flexible pipe and mining robot are affected by the coupling device. So the coupling device should be considered as a major factor when this device is designed. Therefore, we find a stable kinematic device, and apply it to the design coupling device through this study. The kinematic characteristics of the coupling device are analyzed by multi-body dynamics simulation method, and finite element method. The dynamic analysis model was built in the commercial software DAFUL. The Fluid Structure Interaction (FSI) method is applied to build the deep-seabed environment. Hydrodynamic force and moment are applied in the dynamic model for the FSI method. The loads and deformation of flexible pipe are estimated for analysis results of the kinematic characteristics.

벽식 아파트 구조에서 연결부재의 거동특성을 고려한 비선형 동적 응답 (Nonlinear Dynamic Response of Well-Slab Apartment Building Considering The Behavior of Coupling Elements)

  • 김기현;장극관;서대원;천영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.437-442
    • /
    • 2002
  • The purpose of this study is to investigate nonlinear behavior and estimate ultimate resistance of the wall structure against seismic loading. Experimental data for RC coupling elements are used for specifying the strength deterioration and stiffness degradation factor of hysteretic model. Modified coupling element models are used in the push over analysis and time history analysis. In the time history analysis, three earthquake waves are used in the analysis and their peak ground accelerations are changed to be 0.2g. The conclusions of this study are as follows : (1) In the push over analysis, yielding of coupling elements occurred at lower story with small story drift ratio as 0.3%. (2) In the time history analysis, the story drift ratio is sufficient for the requirement of Korean Code, But coupling elements at most stories of the buildings occurred yielding. i. e. the earthquake resistant capacity of shear wall structures is not sufficient at 0.2g.

  • PDF

Comparative Study of Uniform and Nonuniform Grating Couplers for Optimized Fiber Coupling to Silicon Waveguides

  • Lee, Moon Hyeok;Jo, Jae Young;Kim, Dong Wook;Kim, Yudeuk;Kim, Kyong Hon
    • Journal of the Optical Society of Korea
    • /
    • 제20권2호
    • /
    • pp.291-299
    • /
    • 2016
  • We have investigated the ultimate limits of nonuniform grating couplers (NGCs) for optimized fiber coupling to silicon waveguides, compared to uniform grating couplers (UGCs). Simple grating coupler schemes, which can be fabricated in etching steps of the conventional complementary metal-oxide semiconductor (CMOS) process on silicon-on-insulator (SOI) wafers without forming any additional overlay structure, have been simulated numerically and demonstrated experimentally. Optimum values of the grating period, fill factor, and groove number for ultimate coupling efficiency of the NGCs are determined from finite-difference time-domain (FDTD) simulation, and confirmed with experimentally demonstrated devices by comparison to those for the UGCs. Our simulated results indicate that maximum coupling efficiency of NGCs is possible when the minimum pattern size is below 50 nm, but the experimental value for the maximum coupling efficiency is limited by the attainable fabrication tolerance in a practical device process.

접합부 상세에 따른 철골 커플링 보-벽체 접합부의 지압강도 (Bearing Strength of Steel Coupling Beams-Wall Connections depending upon Joint Details)

  • 박완신;윤현도;한병찬;황선경;양일승;김선우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.113-116
    • /
    • 2004
  • No specific guidelines are for computing the shear strength of steel coupling beam connections embedded in the reinforced concrete shear wall. In this paper, a theoretical study of the strength of hybrid coupled shear wall connections is achieved. The bearing stress at failure in the concrete below the steel coupling beam section is related to the concrete compressive strength and the ratio of the width of the steel coupling beam section to the thickness of the hybrid coupled shear wall. To revise factor affecting shear transfer strength across connections between coupled shear walls and steel coupling beam, experimental studies are achieved. The main test variables were auxiliary details of stud bolts. In this studies, these proposed equations are shown to be in good agreement with the test results reported in the paper and with other test data in the literature.

  • PDF

La2O3첨가에 따른 무연 Bi(Na,K)TiO3-SrTiO3 세라믹스의 압전 특성 (Piezoelectric Properties of Pb-free Bi(Na,K)TiO3-SrTiO3 Ceramics with the Amount of La2O3 Addition)

  • 류주현;이현석;박창엽;정광현;이덕출;정영호;홍재일
    • 한국전기전자재료학회논문지
    • /
    • 제17권8호
    • /
    • pp.830-834
    • /
    • 2004
  • In this study, lead-free pirzoelectric ceramics were investigated for pressure sensor applications as a function of the amount of ${La}_2{O}_3$ addition at $Bi(Na, K)Ti{O}_3-SrTi{O}_3$system. With increasing the amount of addition, the density and dielectric constant increased up to 0.9 wt% ${La}_2{O}_3$ addition and decreased above 0.9 wt% ${La}_2{O}_3$addition. Electromechanical coupling factor( $K_{P}$) showed the maximum value at 0.2 wt% ${La}_2{O}_3$addition and decreased above 0.2 wt% ${La}_2{O}_3$ addition. Electromechanical coupling $factor{(K)}_P$, density, dielectric constant$(\varepsilon_\Gamma)$, piezoelectric constant$(d_33)$ and curie temperature$(T_C)$ showed optimum value of 0.40, 5.75 g/㎤, 768, 215 pC/N and 320 $^{\circ}C$ at 0.2 wt%${La}_2{O}_3$addition, respectively.

수열합성에 의한 $Pb(Mn_{1/3} Sb_{2/3})_{0.08} Ti_{0.495}Zr_{0.425}O_3$ 계의 분말제조 및 4K_P$ 특성 (Formation of Powders and Electromechanical Coupling Factor of $Pb(Mn_{1/3} Sb_{2/3})_{0.08} Ti_{0.495}Zr_{0.425}O_3$ by Hydrothermal Synthesis)

  • 이명교;홍창희
    • 한국세라믹학회지
    • /
    • 제23권3호
    • /
    • pp.15-20
    • /
    • 1986
  • Formation of powders and electromechanical coupling factor of $Pb(Mn_{1/3} Sb_{2/3})_{0.08} Ti_{0.495}Zr_{0.425}O_3$ by hydro-thermal synthesis are described. The hydrothermal reactions each were accomplished at 12$0^{\circ}C$~25$0^{\circ}C$ for 5hours and sintering was accomplished at 1, .20$0^{\circ}C$ for 1hours. The PZT powders by hydrothermal synthesis were formed above 16$0^{\circ}C$ and the forms were cubic types. The ratio of grain size of sintered sample to powder was slowly decreased with the rising of hydrothermal reactino temperature but decreased rapidly above 22$0^{\circ}C$ Sintering density was decreased with the rising of hydrothermal reaction temperature above 16$0^{\circ}C$ but dielectric constant was increased. Electromechanical coupling factor $K_P$ was almost constant at 16$0^{\circ}C$~24$0^{\circ}C$ range and the value of $K_P$ was about 0.43-0.45.

  • PDF

심벌형 압전 에너지 하베스터 에너지 수율 향상 연구 (Research on the Efficiency Improvement of the Cymbal-type Piezoelectric Energy Harvester)

  • 나영민;박종규
    • 한국기계가공학회지
    • /
    • 제16권1호
    • /
    • pp.70-76
    • /
    • 2017
  • The pollution problem of fossil energy sources has caused the development of green energy harvesting systems. Piezoelectric energy harvesting technology has been developed under those external environmental factors. A piezoelectric energy harvester can be defined as a device which transforms mechanical vibration or impact energy into electrical energy. Most researches have focused on bender structures. However, these have a limitation on energy efficiency because of the small effective electromechanical coupling factor, around 10%. Therefore, we should look for a new design for energy harvesting. A cymbal energy harvester can be a good candidate for the high-power energy harvester because it uses a high amplification mechanism using endcaps while keeping a higher electromechanical coupling factor. In this research, we focused on energy efficiency improvements of the cymbal energy harvester by changing the polarization direction, because the electromechanical coupling factor of the k33 mode and the k15 mode is larger than that of the k31 mode. Theoretically, we checked the cymbal harvester with radial polarization and it could obtain 6 times larger energy than that with the k31 direction polarization. Furthermore, we verified the theoretical expectation using the finite element method program. Consequently, we could expect a more efficient cymbal harvester with the radial polarization by comparing two polarization directions.

MnO$_2$가 첨가된 PMW-PNN-PT-PZ계 세라믹스의 유전 및 압전 특성 (Dielectric and Piezoelectric Characteristics of PMW-PNN-PT-PZ Ceramics with addiction of MnO$_2$)

  • 박석환;윤광희;박정흠;김현재;박창엽
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.63-67
    • /
    • 1996
  • In this paper, effect of MnO$_2$ addition(0, 0.1, 0.2, 0.3, 0.5wt%) on the microstructure, dielectric and piezoelectric properties of [xPMW - (0.15-x) PNN] - [yPT-(0.85-y)PZ] (x=0, 0.01, 0.02, 0.03, 0.05, y = 0.35, 0.40, ().425, 0.45, 0.5) were investigated. When Ti/Zr ratio was 1.0, dielectric and piezoelectric properties were highest value. With PMW 2mol%, dielectric constant, dielectric constant (d$\_$33/, d$\_$31/) and electromechanical coupling factor (kp, k$\_$31/) were highest values of 1995, 479, 186(x10$\^$-12/C/N), 0.61, 0.36, respectively. With the addition of MnO$_2$, dielectric constant, electromechanical coupling factor (kp, k$\_$31/) were decreased, but with 0.3wt% MnO$_2$, eletromechanical coupling factor was highest value of 0.63. With the addition of MnO$_2$, mechanical quality(Q$\_$m/ was increased.

  • PDF

강우침투에 의한 비탈면 안정해의 수리-역학적 모델을 이용한 커플링 효과 (Coupling Effects in Rainfall-induced Slope Stability Considering Hydro-mechanical Model)

  • 김용민;정상섬
    • 한국지반공학회논문집
    • /
    • 제31권9호
    • /
    • pp.5-15
    • /
    • 2015
  • 본 연구에서는 수리-역학적 유한요소 해석기법을 바탕으로 강우침투에 의한 비탈면 안정성과 커플링 효과를 분석하였다. 이를 위해 수리학적 특성과 역학적 특성을 동시에 고려할 수 있는 해석기법을 개발 하였으며, 현장모관흡수력 측정 결과를 활용하여 해석기법을 검증하였다. 이를 바탕으로 균질한 지층과 비탈면을 모델링 하여 강우발생에 따른 모관흡수력 변화, 평균유효응력, 간극률 변화, 지반 변위, 안전율의 결과를 단계별 해석결과와 비교 분석하였다. 그 결과, 간극률의 변화를 고려할 수 있는 커플링 해석의 변위는 단계별 해석에 비해 크게 나타났으며, 모관흡수력은 천천히 감소하는 것으로 나타났다. 커플링 해석을 통해 동시에 계산된 변형과 모관흡수력 감소는 비탈면의 불안정성에 큰 영향을 미치며, 점진적 파괴거동을 확인할 수 있다. 커플링 해석을 통한 비탈면 안정해석 시, 단기간 발생한 강우에 대해 낮은 안전율을 보여 커플링 효과가 큰 것으로 나타났으며, 집중호우에 의한 비탈면 설계 시 커플링 해석이 필요함을 알 수 있었다.