• Title/Summary/Keyword: countermeasure method

Search Result 501, Processing Time 0.023 seconds

Numerical Analysis on Effective Countermeasure for Ground Subsidence due to Mining Hazard (광해로 인한 지반침하의 효율적인 보강방안에 관한 수치해석)

  • Hong, Won-Pyo;Lee, Jae-Ho;Hur, Se-Young
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.4
    • /
    • pp.7-13
    • /
    • 2007
  • When the structure such as roadway, railway are constructed on abandoned coal mine area, the countermeasure to prevent settlements is necessary. In this study, numerical analyses are performed to evaluate the effect of the various countermeasures. As a results, the method which is filling the coal mine is more effective than that of reinforcing the ground above the coal mine. The ground settlement decreases hyperbolically with increasing the filling ratio of the coal mine. Also, the relationship between the filling ratio and the settlement reduction ratio is discussed precisely.

  • PDF

The Hazard Grade Classification Criterion using Character of Collapsed Cut Slope by Rainfall (강우에 의해 붕괴된 절토사면의 특성을 이용한 절토사면 위험등급 분류기준)

  • Yoo, Ki-Jeong;Koo, Ho-Bon;Baek, Yong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.600-605
    • /
    • 2004
  • The road construction with horizontal expansion of country using and augmentation of traffic demand is advanced actively and it accompanies hereupon, the above of 70% of the country is formed at the mountain in our country where the hazard cut slope has been created. In this study, It is prepared a effective management countermeasure of cut slope introduced priority investigation decision method against hazard cut slope which is influenced by abnormally rainfall by an unusual change in the weather such as a guerilla rainfall character. In meaning link, It was executed collapse cause by failure character analysis in the cut slope which has failed for the last five years and it is prepared the hazard grade criterion from E to A grade according to collapse cause. It is decided that a maintenance management grade by the hazard grade classification criterion of cut slope. So It is possible to hazard cut slope. It is established failure protection counter countermeasure by effective maintenance management through the hazard grade c1assification criterion and it will be able to dispose to advanced nation level like Hong Kong and Japanese.

  • PDF

Analysis in Technological Responses to Side-channel Attack (부채널 공격에 대한 대응기술 분석)

  • d, Young-Jin;Jo, JungBok;Lee, HoonJae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.219-222
    • /
    • 2013
  • The Side Channel attack methods proposed by P.Kocher are mainly used for cryptanalysis different cipher algorithms even though they are claimed to be strongly secured. Those kinds of attacks depend on environment implementation especially on the hardware implementation of the algorithm to the crypto module. side-channel attacks are a type of attack introduced by P.Kocher and is applicable according to each environment or method that is designed. This kind of attack can analyze and also extract important information by reading the binary code data via measurement of changes in electricity(voltage) consumption, running time, error output and sounds. Thus, in this paper, we discuss recent SPA and DPA attacks as well as recent countermeasure techniques.

  • PDF

Vibration Reducing Method for High Pressure Feedwater Heater Drain Piping System (고압급수가열기 배수계통 배관계 고진동 해소방안 연구)

  • Lee, Wook-Ryun;Lee, Jun-Shin;Kim, Sang-Bok;Hong, Soon-Bup;Shin, Yong-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1290-1295
    • /
    • 2006
  • The 120 meters high pressure feedwater heater drain piping in nuclear power plant had been suffered by excessive vibration from the beginning of power generation. As time goes by, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of high pressure feedwater heater drain piping and the countermeasure for abnormal vibration were investigated. Among the several vibration reduction methods, the piping layout changed by making the smooth pipeline was applied to the high Pressure feedwater heater drain piping in nuclear Power plant. Applying the countermeasure, the vibration level was found to reduce over 54 percents and was satisfied under the allowable velocity at the full-power operation condition.

  • PDF

A Study on Application of Dimethoxy Methane and EGR Method for Simultaneous Reduction of Smoke and NOx Emission (매연과 NOx의 동기저감을 위한 Dimethoxy Methane과 EGR방법의 적용에 관한 연구)

  • Choi, Seung-Hun;Oh, Young-Taig;Hwang, Yun-Taig;Song, Ki-Hong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.448-453
    • /
    • 2003
  • In this study, the effects of oxygen component in fuel and exhaust gas recirculation(EGR) method on the exhaust emissions has been investigated for a D.I. diesel engine. It was tested to estimate change of exhaust emission characteristics for the commercial diesel fuel and oxygenate blended fuel which has five kinds of blending ratio. Dimethoxy methane(DMM) contains oxygen component 42.5% in itself. and it is a kind of effective oxygenated fuel for reduction of smoke emission. It was affirmed that smoke emission was decreased with increasing of DMM blending ratio. But, NOx emission was increased compared with commercial diesel fuel. It was needed a NOx reduction countermeasure that EGR method was used as a countermeasure for NOx reduction. It was found that simultaneous reduction of smoke and NOx emission was achieved with DMM blended fuel and cooled EGR method($10{\sim}15%$).

  • PDF

A Study on the Priority Ranks to Improve Work Environments in the Worker's Point of View (작업환경 소음 개선을 위한 작업자 관점의 우선순위 파악에 관한 연구)

  • Kim, Hwa-Il
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.202-212
    • /
    • 2005
  • This study was aimed at rating the existing work environment noise components and alternatives in point of worker's view. To answer the purpose, AHP(Analytic Hierarchy Process) method is adopted in this research. Based on the AHP method, this research abstracts a mathematically rigorous noise components and alternative's weights and proven process for priority and decision-making. By reconstructing complex hearing conservation programs to a series of pair-wise comparisons, and then synthesizing the results, this study not only helps establishments of noise countermeasure, but also provides a clear rationale for noise alternatives. The result of this study is summarized as follows; 1) Job satisfaction index and noise identification index are 63, 56 respectively. 2) Noise level(15.7%), frequency(14.1%) and directivity(13.6%) are main reasons in worker's ground. 3) There are some difference between the estimation of worker's identification and that of work sites. 4) Low noise machine(14.7%), enclosure(13.2%) and shielding(9.6%) are chosen for noise protection method by workers. 5) Noise environment improvement should be focused on noise source rather than personal protection. 6) By the AHP method, noise source countermeasure have a key role at work environments.

An Experiment Study on the Structure-borne Noise Reduction of Building Nearby the Road by Using Ballast Mat Pavement Method (도상 매트 공법 도로포장에 의한 자동차 도로 인근 건축물의 고체전파음 저감효과에 관한 실험적 연구)

  • 이익주;유제남
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1153-1160
    • /
    • 2004
  • In contemporary society, vibration and noise in the road nearby buildings have become social problems as vehicles operation has increased. Especially. in the case of the building used to art performance, available suitability of the building is tested by the indoor noise class. Therefore, the Purpose of this paper is the measurement of the structure-borne noise of Seoul Art Center nearby Umyeonsan tunnel and analyzing the effects of countermeasure to it. To measure the effects of countermeasure, not only structure-borne noise is measured, but also the vibration is measured, before and after the construction of Pavement using pad and porous asphalt. Consequently, the sound pressure level in art center 1st floor is reduced after mat pavement method, structure-borne noise that was high In 25Hz wide-band before pavement decreased regardless of experimental vehicle's velocity Using porous asphalt pavement the noise was reduced about 3 dB(A).

Effective Countermeasure to APT Attacks using Big Data (빅데이터를 이용한 APT 공격 시도에 대한 효과적인 대응 방안)

  • Mun, Hyung-Jin;Choi, Seung-Hyeon;Hwang, Yooncheol
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.1
    • /
    • pp.17-23
    • /
    • 2016
  • Recently, Internet services via various devices including smartphone have become available. Because of the development of ICT, numerous hacking incidents have occurred and most of those attacks turned out to be APT attacks. APT attack means an attack method by which a hacker continues to collect information to achieve his goal, and analyzes the weakness of the target and infects it with malicious code, and being hidden, leaks the data in time. In this paper, we examine the information collection method the APT attackers use to invade the target system in a short time using big data, and we suggest and evaluate the countermeasure to protect against the attack method using big data.

Practical Second-Order Correlation Power Analysis on the Message Blinding Method and Its Novel Countermeasure for RSA

  • Kim, Hee-Seok;Kim, Tae-Hyun;Yoon, Joong-Chul;Hong, Seok-Hie
    • ETRI Journal
    • /
    • v.32 no.1
    • /
    • pp.102-111
    • /
    • 2010
  • Recently power attacks on RSA cryptosystems have been widely investigated, and various countermeasures have been proposed. One of the most efficient and secure countermeasures is the message blinding method, which includes the RSA derivative of the binary-with-random-initial-point algorithm on elliptical curve cryptosystems. It is known to be secure against first-order differential power analysis (DPA); however, it is susceptible to second-order DPA. Although second-order DPA gives some solutions for defeating message blinding methods, this kind of attack still has the practical difficulty of how to find the points of interest, that is, the exact moments when intermediate values are being manipulated. In this paper, we propose a practical second-order correlation power analysis (SOCPA). Our attack can easily find points of interest in a power trace and find the private key with a small number of power traces. We also propose an efficient countermeasure which is secure against the proposed SOCPA as well as existing power attacks.

A Countermeasure Resistant to Fault Attacks on CRT-RSA using Fault Infective Method (오류 확산 기법을 이용한 CRT-RSA 오류 주입 공격 대응 방안)

  • Ha, Jae-Cheol;Park, Jea-Hoon;Moon, Sang-Jae
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.18 no.2
    • /
    • pp.75-84
    • /
    • 2008
  • Recently, the straightforward CRT-RSA was shown to be broken by fault attacks through many experimental results. In this paper, we analyze the fault attacks against CRT-RSA and their countermeasures, and then propose a new fault infective method resistant to the various fault attacks on CRT-RSA. In our CRT-RSA algorithm, if an error is injected in exponentiation with modulo p or q, then the error is spreaded by fault infective computation in CRT recombination operation. Our countermeasure doesn't have extra error detection procedure based on decision tests and doesn't use public parameter such as e. Also, the computational cost is effective compared to the previous secure countermeasures.