• Title/Summary/Keyword: counterflow

Search Result 264, Processing Time 0.025 seconds

Investigation of Effects of Duct Thickness an Counterflow Flam Structure (닥트두께가 대향류 화염구조에 미치는 영향의 조사)

  • Park, Woe-Chul;Ko, Kyung-Chan
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.61-65
    • /
    • 2002
  • Nonpremixed counterflow flames at low strain rates, $ag=12s^{-1}$ and $12s^{-1}$, were numerically simulated to investigate the effects of the duct thickness on the flame structure in normal gravity. For small values of the duct thickness, the positions of the flame and stagnation point were highly sensitive to the duct thickness. When the duct thickness was greater than 6mm, however, the effects of the duct thickness on the flame structure were negligible. The computed temperature along the duct centerline agreed well with measurements.

Experimental Study on Extinction Behavior in Buoyancy-minimized Counterflow Diffusion Flame (부력 효과의 최소화를 통한 대향류 확산화염 소화거동에 관한 실험적 연구)

  • Chung, Yong Ho;Park, Jeong;Kwon, Oh Boong;Yun, Jin-Han;Kee, Sang-In;Kim, Young Ju
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.4
    • /
    • pp.38-43
    • /
    • 2012
  • Experimental study was conducted to elucidate flame extinction phenomena in counterflow flame. Using a curtain helium flow significantly reduced buoyancy such that the flame can be positioned at the center between the upper and lower nozzles even at the velocity ratio of 1.0. The curves of critical diluent mole fraction versus global strain rate have C-shapes. The flame oscillation was observed prior to low strain rate flame extinction at both flame conditions with and without minimizing buoyancy force. The results show that, at low strain rate flame, the self-excitation frequency with the order of 1.0 Hz in the case of utilizing pure helium gradually decreases in increase of $N_2$ mole fraction in the curtain flow, meaning that buoyancy suppresses the self-excitation of the outer edge flame.

Linear Stability Analysis of Cellular Counterflow Diffusion Flames with Radiation Heat Loss (복사 열손실을 받는 셀모양 대향류 확산화염의 선형 안정성 해석)

  • Lee, Su Ryong
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.2
    • /
    • pp.42-50
    • /
    • 2013
  • Linear stability analysis of radiating counterflow diffusion flames is numerically conducted to examine the instability characteristics of cellular patterns. Lewis number is assumed to be 0.5 to consider diffusional-thermal instability. Near kinetic limit extinction regime, growth rates of disturbances always have real eigen-values and neutral stability condition of planar disturbances perfectly falls into quasi-steady extinction. Cellular instability of disturbance with transverse direction occurs just before steady extinction. However, near radiative limit extinction regime, the eigenvalues are complex and pulsating instability of planar disturbances appears prior to steady extinction. Cellular instability occurs before the onset of planar pulsating instability, which means the extension of flammability.

A Numerical Study on the Lean-Rich Interaction of Methane/Air Flames (희박-과농 메탄 화염의 상호작용에 관한 수치해석적 연구)

  • Lee, Seung-Dong;Jeong, Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.377-383
    • /
    • 1996
  • Interaction of flames in a lean-rich concentration field is studied numerically adopting a counterflow as a model problem. Detailed kinetic mechanism is adopted in analyzing the structure of various type of flames which can be found in lean-rich interaction. Flow field is simplified to quasi one-dimensional by using boundary layer approximation and similarity formulation. Triple flames are identified and its structure shows that a diffusion flame is located in the middle of two premixed flames. Such a diffusion flame is formed by $H_2$ and CO generated from the rich premixed flame and $O_2$ leaked from the lean premixed flame. The flame position can be identified either from the hydrogen production rate or the heat release rate. Transition from single diffusion flame to triple flame is observed as degree of premixing is increased.

Parametric Study on the Performance of a Counterflow Type Cooling Tower

  • Shin, Jee-Young;Son, Young-Seok
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.1
    • /
    • pp.17-23
    • /
    • 2003
  • A design procedure for cooling towers was set up using the Merkel theory In the past, the design data could be different depending on the characteristic curve that the engineer adopted. Therefore, consistent and reasonable criteria are required, which are based on the exact information of the cooling tower performance. In this study, analysis program for both the design and off-design for a counterflow-type cooling tower was developed and verified by comparing with experimental data. The off-design performance with various operating conditions was analyzed, as well.

Effect of Radiation Models on the Suppression Limits in Counterflow Methane/Air Diffusion Flames (대향류 메탄/공기 확산화염에서 복사모델이 소화한계에 미치는 영향)

  • Mun, Sun-Yeo;Cho, Jae-Ho;Hwang, Cheol-Hong;Oh, Chang Bo;Park, Won-Hee
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.20-28
    • /
    • 2014
  • Effect of radiation models on the suppression limits in counterflow $CH_4$/air diffusion flame was numerically investigated with fundamental experiments for the numerical validation. $N_2$ and $CO_2$ were considered as extinguishing agents. The differences in extinguishing concentration between OTM and SNB radiation models which have different accuracy levels were examined. As a result, there is no considerable difference in extinguishing concentration for the $N_2$ dilution as the radiation models with different accuracy levels were used. As the $CO_2$ having strong radiative effect was diluted in the low strain flames, however, the radiation model with high predictive accuracy such as SNB should be used. In particular, the $CO_2$ dilution in fuel stream leads to the significant difference in extinguishing concentration between OTM and SNB models. Therefore, it is necessary that the radiation model should be reasonably chosen with the consideration of numerical accuracy and computational time for the prediction of extinguishing concentration.

Numerical Analysis of Characteristics of Cellular Counterflow Diffusion Flames near Radiative Extinction Limit (복사 열손실에 의한 소염근처에서 셀모양 대향류 확산화염의 특성에 대한 수치해석)

  • Lee, Su Ryong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.493-500
    • /
    • 2014
  • Nonlinear characteristics of cellular counterflow diffusion flame near the radiative extinction limit at large Damk$\ddot{o}$hler number are numerically investigated. Lewis number is assumed to be 0.5 and flame evolution is calculated by imposing an infinitesimal disturbance to a one-dimensional(1-D) steady state flame. The early stage of nonlinear development is very similar to that predicted in a linear stability analysis. The disturbance with the wavenumber of the fastest growing mode emerges and grows gradually. Eventual, an alternating pattern of reacting and quenching stripes is developed. The cellular flame temperature is higher than that of 1-D flame because of the gain of the total enthalpy. As the Damk$\ddot{o}$hler number is further increased, the shape of the cell becomes circular to increase the surface area per unit reacting volume. The cellular flames do not extinguish but survive even above the 1-D steady state extinction condition.

Axisymmetric Simulation of Nonpremixed Counterflow Flames - Effects of Fuel Concentration on Flame Structure - (비예혼합 대향류 화염의 축대칭 모사 - 연료농도가 화염구조에 미치는 영향 -)

  • Park Woe-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.3 s.20
    • /
    • pp.44-50
    • /
    • 2003
  • The axisymmetric methane-air counterflow flame was simulated to investigate changes in the flame structure due to the fuel concentration and to evaluate the numerical method. The global strain rates $a_g=20,\;60,\;90\;s^{-1}$ and the mole fractions of methane $x_m=20,\;50,\;80\%$ in the fuel stream were taken to be numerical parameters. The axisymmetric simulation was conducted by using the Fire Dynamics Simulator (FDS) which employed a mixture fraction combustion model, and the results were compared with those of OPPDIF, which is an one-dimensional flamelet code and includes detail chemical reactions. In all the cases tested, there was good agreement in the temperature and axial velocity profiles between the axisymmetric and one-dimensional simulations. It was shown that the flame thickness and peak flame temperature increase and the flame radius decreases as the fuel concentration increases.

  • PDF

Numerical Investigation of Low-pollution Combustion with applying Flue Gas Recirculation in Counterflow Flames: Part I. Combustion Characteristics of Low NOx (대향류 화염에서 FGR이 적용된 저공해 연소의 수치적 해석: Part I. 저 NOx 연소특성)

  • Cho, Seo-Hee;Lee, Kee-Man
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.8-16
    • /
    • 2019
  • One of the methods for low-pollution combustion, flue gas recirculation(FGR) is effective to reduce nitrogen oxides and it was applied in CH4/air premixed counterflow flames to identify the change of flame characteristics and NOx mechanisms. Considering that the mole fraction of the products varied depending on the strain rates, the major products: CO2, H2O, O2 and N2 were recirculated as a diluent to reflect the actual combustion system. With the application of the FGR technique, a turning point of maximum flame temperature under certain strain rate condition was found. Furthermore as the recirculation ratio increased, the tendency of NO was changed before and after the turning point and the analysis on thermal NO and Fenimore NO production was conducted.