• Title/Summary/Keyword: corrosivity

Search Result 42, Processing Time 0.018 seconds

Corrosivity of Atmospheres in the Korean Peninsula

  • Kim, Y.S.;Lim, H.K.;Kim, J.J.;Park, Y.S.
    • Corrosion Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.109-117
    • /
    • 2011
  • The Korean Peninsula is located in the middle latitude of the northern hemisphere and has a clear 4-seasons and shows the typical temperate climate. Because of seasonal winds, it is cold and dry by a northwestern wind in the winter and it is hot and humid by a southeast wind in the summer. Also, temperature difference between the winter and the summer is large and it shows a rainy season from June to July but recently this regular trend may be greatly changed by an unusual weather phenomena. Since the Peninsula is east high west low type, the climate is complicated too. Because these geographical and climate characteristics can affect the properties of corrosion of metals and alloys, a systematic research on atmospheric corrosion in the Peninsula is required to understand and control the corrosion behavior of the industrial facilities. This paper analyzed the atmospheric corrosion factors for several environments in the Korean Peninsula and categorized the corrosivity of atmospheric corrosion of metals and alloys on the base of the related ISO standards. Annual pH values of rain showed the range of 4.5~5.5 in Korean Peninsula from 1999 to 2009 and coastal area showed relatively the low pH's rain. Annual $SO_2$ concentrations is reduced with time and its concentrations of every major cities were below the air quality standard, but $NO_2$concentration revealed a steady state and its concentration of Seoul has been over air quality standard. In 2007, $SO_2$classes of each sites were in $P_0{\sim}P_1$, and chloride classes were in $S_0{\sim}S_1$, and TOW classes were in ${\tau}_3{\sim}{\tau}_4$.That is, $SO_2$ and chloride classes were low but TOW class was high in Korean Peninsula. On the base of these environmental classes, corrosivity of carbon steel, zinc, copper, aluminium can be calculated that carbon steel was in C2-C3 classes and it was classified as low-medium, and zinc, copper, and aluminium showed C3 class and it was classified as medium.

Effect of corrosive water quality control and corrosion index monitoring in pilot scale pipeline simulator (파일럿 규모 모의관로에서 부식성 수질제어 효과와 부식지수 모니터링)

  • Kim, Do-Hwan;Kim, Yung-Jin;Son, Hee-Jong;Ryou, Dong-Choon;Ahn, Jun-Young;Kim, Cheolyong;Hwang, In-Seong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.183-192
    • /
    • 2018
  • Applicability of corrosion inhibitor was evaluated using pilot scale water distribution pipe simulator. Calcium hydroxide was used as corrosion inhibitor and the corrosion indices of the water were investigated. Corrosion indices, Langelier saturation index (LI) increased by 0.8 and calcium carbonate precipitation potential (CCPP) increased by 9.8 mg/L. This indicated that corrosivity of water decreased by corrosion inhibitor and the effects lasted for 18 days. Optimum calcium hydroxide dose was found to be 3~5 mg/L for corrosion inhibition. We suggest that monitoring of CCPP as well as LI need to be conducted to control corrosivity of water.

The characteristics of leachate migration and corrosivity in municipal wastefills at seaside (해안 도시폐기물 매립지의 침출수 이동 특성 및 부식성)

  • Jang, Yeon-Su;Jeong, Ha-Ik;Kim, Jin-Man
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1992.12a
    • /
    • pp.33-66
    • /
    • 1992
  • Recently, waste landfills built on seashores have been increased because of the easy availability of broad area near the urban communities. To evaluate the performance of the marine clay landfill liner numerical contaminant transport analyses are performed by selecting the typical section of a waste landfill built on seashores and using hydraulic conductivity data obtained from the site. Also, the laboratory electrical resistivity test and the in-situ corrosion test are performed in order to analyze the influence of the soil and leachates composing the landfills on the construct ion materials. From the results of contaminant transport analyses, it is shown that the leachates can be migrated faster through narrow pervious channels than the wide homogeneous pervious tedium and the importance of good quality barriers to prevent the contaminant migration is recognized. In the laboratory electrical resistivity test all the earth materials except the cover soils saturated with distilled water have small resistivities, which shows a high potential of corrosivity of soils composing landfills. However, the degree of corrosion of specimens buried in the landfills was not so severe except the zinc and carbon steel specimens. This apparently conflict results present the necessity of the investigation of other major factors and the long term in-situ corrosion test.

  • PDF

Assessment of Atmospheric Corrosivity at Jeju Island (제주도 대기환경의 부식성 평가)

  • KIM GUI-SHIK;YANG KYEONG-CHO;HU CHUL-GOO;SONG JEONG-HWA
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.5 s.66
    • /
    • pp.50-57
    • /
    • 2005
  • This study has been conducted to investigate corrosivity of carbon steel, Cu, Zn and Al for one year from Sept. 2003 to Aug. 2004. A model of ISO 9223-ISO 9226 that represents the relation between metal corrosions and environmental parameters was used for atmospheric corrosion evaluations. Environmental parameters for these evaluations are time of wetness(TOW), $SO_2$ and Chloride. Corrosion rates for four metals which are exposed indoors and outdoors were measured on five locations in Jeju Island; Gosan, Seogwipo, Seongsan, Chuna hill and Jeju city. The environmental factor of atmospheric corrosion of Jeju Island for $SO_2$ class is P0, a clean area. TOW as T3 and T4 indicates that Jeju has the characteristics of a tropical area. Chlorides class within 3 km from the coast show the features of costal area as S2 and S3 classes. Chuna hill show the features of woodland as a S1 class. In Corrosion classes of each site which was measured outdoors is higher than indoors. Gosan is the highest class as the rank of C5, and indicated that they're ranked as C3 or C4.

Atmospheric Corrosion Behavior of Carbon Steel by the Outdoor Exposure Test for 10 Years in Korea

  • Yoo, Y.R.;Choi, S.H.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.184-199
    • /
    • 2022
  • Steel was exposed in an atmospheric environment, and atmospheric environmental factors that include chloride, humidity, SO2, NO2 etc. induced the corrosion of steel. Corrosivity categories classified by SO2 and chloride deposition rate were low, but those classified by TOW were high in the Korean Peninsula, and on these environmental categories, the corrosivity of atmospheres classified by corrosion rate in carbon steel was low medium, C2-C3, and medium, C3 for zinc, copper, and aluminum. This work performed the outdoor exposure test for 10 years at 14 areas in Korea and calculated the atmospheric corrosion rate of carbon steel. The atmospheric corrosion behavior of carbon steel is discussed based on the various corrosion factors. When the corrosion product forms on carbon steel by atmospheric corrosion, cracks may also be formed, and through these cracks, the environmental factors can penetrate into the interior of the product, detach some of the corrosion products and finally corrode locally. Thus, the maximum corrosion rate was about 7.3 times greater than the average corrosion rate. The color difference and glossiness of carbon steel by the 10 year-outdoor exposure tests are discussed based on the corrosion rate and the environmental factors.

A Comparison of Four Atmospheric Corrosivity Modeling Results for Aircraft (4개 모델에 따른 항공기의 대기 부식성 모의 결과 비교)

  • Mu-sung Woo;Jae-won Lee;Ji-hye Lee;Kyong-jin Woo;Jongchul Park
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.31 no.3
    • /
    • pp.79-92
    • /
    • 2023
  • Aluminum alloys are important materials in modern aircraft. Aircraft failures due to corrosion are fatal and costly. Thus, information about the atmospheric corrosion of aluminum is helpful for aviation safety. This study employed four corrosion models and 12 environmental variables to improve knowledge of aluminum atmospheric corrosivity: PACER LIME, ICP, ISO CORRAG, and a modified model of CORRAG. This study applied each model on 47 aircraft operating bases in Korea and compared the results. In the results, The risk of corrosion was different for each model. The cause was the difference in environmental variables according to the model. Especially, the effect of ozone, which has recently been increasing, was shown in the results of PACER LIME. These findings suggest that caution is needed when assessing atmospheric corrosion risk as a single model. Furthermore, it means that the application and integration of various models are needed to improve atmospheric corrosion risk assessment.

Characteristics of Fluoride-based Anti-stain Chemicals Made from industrial By-product (I) - Anti-mold Effectiveness, Iron Corrosivity and Hygroscopicity - (산업 부산물을 이용하여 제조한 플루오르화합물계 목재 방미제의 특성 (I) - 목재 방미효력 및 철부식성과 흡습성 -)

  • Lee, Jong-Shin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.73-81
    • /
    • 2004
  • To develope of the inexpensive anti-stain chemicals, it was conducted to investigate the inhibitory effectiveness of mycelial growth and anti-mold effectiveness against test fungi causing surface mold of wood, iron corrosivity and hygroscopicity of six fluoride-based chemicals made from industrial by- product.Among the six chemicals. RNF-3 and RNF-4 were the most effective with respect to a mycelial growth control and anti-mold effectiveness. For the wood treatment with these chemicals, the optimum concentration was about 2% and there was no difference in the effectiveness of chemicals between wood species. The wood treated with synthesized chemicals showed a relatively high iron corrosion rate for corrosive F component whereas, in the treatment with RNF-3 and RNF-4, there was no difference from the untreated wood when the concentration was less than 2%. The hygroscopic property of wood was not effected by treatment of these chemicals. To prove the feasibility for practical using of RNF-3 and RNF-4 chemicals, it is necessary to test of anti-mold effectiveness in the sawmill by field test.

Antimicrobial and Other Properties of a New Stabilized Alkaline Glutaraldehyde Disinfectant/Sterilizer (병원에서 사용하는 수술도구 살균제, glutaraldehyde 용액의 살균 효과에 관하여)

  • 궁리환
    • YAKHAK HOEJI
    • /
    • v.31 no.4
    • /
    • pp.236-251
    • /
    • 1987
  • The chemistry, antimicrobial properties, organic soil resistance, toxicity, corrosivity and chemical stability of stabilized alkaline 2%, glutaraldehyde solution(SGS) are discussed. SGS retains the maximum antimicrobial activity of alkaline glutaraldehyde solutions and the chemical stability here to fore observed only with acidic glutaraldehyde solutions. These improvements, along with the inherent resistance of glutaradehyde to neutralization by organic soil, allow SGS to be continuously used for 14 days in situations of high dilution, or 28 days in situations of low dilution.

  • PDF

Corrosion Control in Water Pipes by Adjusting the Corrosivity of Drinking Water : Effect and impact of the Corrosion Inhibitor (수돗물 부식성 제어를 통한 수도관 부식방지 : 부식억제제별 효과와 영향에 대한 분석)

  • Park, Young-Bog;Park, Ju-Hyun;Park, Eun-Hee;Lee, Jin-Suk;Kim, Hyen-Ton;Choi, Young-June;Chung, Hyen-Mi;Huh, Yu-jeong;Choi, In-cheol
    • Corrosion Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.303-310
    • /
    • 2016
  • The tap water used in Seoul was found to be corrosive. Its corrosivity was effectively reduced by that the additions of alkali agent such as NaOH, $Ca(OH)_2$ and corrosion inhibitor such as $H_3PO_4$. For the corrosion test, carbon steel pipe 50 m long was exposed to the drinking water produced by a pilot plant at $36.5^{\circ}C$, similar to the existing process where it takes about 20 minutes to reduce the initial chlorine content of 0.5 mg/L to 0.05 mg/L. $CO_2$ and $Ca(OH)_2$ was added not only to control the Langelier index (LI) above -1.0 and but also, to increase the duration time of residual chlorine by about 6 times. The persistence effect of residual chlorine was in the order of $H_3PO_4$ > $Ca(OH)_2$ > NaOH. Measurements of weight loss showed that corrosion inhibition was effective in order of $Ca(OH)_2$ > $H_3PO_4$ > NaOH > no addition, where the concentrations of $Ca(OH)_2$ and phosphate were 5 ~ 10 mg/L (as $Ca^{2+}$) and 1 mg/L (as $PO{_4}^{3-}$), respectively.

A Study on the Physical Properties and Coating of Metal Surface Using Traditional Lacquer Technique (전통 옻칠 기법을 이용한 금속표면 코팅 및 물성 연구)

  • Cho, Sung Mo;Oh, Han Seo;Cho, Nam Chul
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.302-311
    • /
    • 2021
  • This study uses traditional lacquer techniques to coat the metal surface and evaluates its physical properties to check the applicability of the lacquer coating. For this purpose, a total of six specimens were produced by setting the variation conditions for the number of times (1, 2, 3) and the heating temperature (120℃, 150℃) using SS275 metal(60*60 mm) and 'Wonju lacquer'. For analysis, chromaticity measurements, contact angle/surface energy measurements, Chemical Resistance, and cross-cut tests were used. The analysis showed that the corrosivity was improved and the adhesion of lacquer to the metal surface was excellent. There was no significant change in contact angle/surface energy. Also, there was no significant difference in color. Through this study, it was confirmed that lacquer on metal surfaces improves waterproofing and has a anticorrosion effect. We could also check the proper number of lacquer and heating temperature. Additional physical characteristics such as hardness and wear rate should be studied. It is also necessary to study how lacquer can be painted with a certain thickness.