• Title/Summary/Keyword: corrosion area

Search Result 571, Processing Time 0.022 seconds

Assessment of Atmospheric Corrosivity at Jeju Island (제주도 대기환경의 부식성 평가)

  • KIM GUI-SHIK;YANG KYEONG-CHO;HU CHUL-GOO;SONG JEONG-HWA
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.5 s.66
    • /
    • pp.50-57
    • /
    • 2005
  • This study has been conducted to investigate corrosivity of carbon steel, Cu, Zn and Al for one year from Sept. 2003 to Aug. 2004. A model of ISO 9223-ISO 9226 that represents the relation between metal corrosions and environmental parameters was used for atmospheric corrosion evaluations. Environmental parameters for these evaluations are time of wetness(TOW), $SO_2$ and Chloride. Corrosion rates for four metals which are exposed indoors and outdoors were measured on five locations in Jeju Island; Gosan, Seogwipo, Seongsan, Chuna hill and Jeju city. The environmental factor of atmospheric corrosion of Jeju Island for $SO_2$ class is P0, a clean area. TOW as T3 and T4 indicates that Jeju has the characteristics of a tropical area. Chlorides class within 3 km from the coast show the features of costal area as S2 and S3 classes. Chuna hill show the features of woodland as a S1 class. In Corrosion classes of each site which was measured outdoors is higher than indoors. Gosan is the highest class as the rank of C5, and indicated that they're ranked as C3 or C4.

A study on Corrosion of Steel in Mortar under the Environment of Artificial Seawater (인공 해수에 침적한 모르터 중의 철근 부식에 대한 연구)

  • 문한영;김성수;류재석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.04a
    • /
    • pp.73-78
    • /
    • 1993
  • This study was performed for the purposes of estimating steel corrosion of concrete structures under the environment of seawater. The corrosion of steel was accelerated in artificial seawater with seven kinds of specimen which was embedded in mortar. By measuring choride content in mortar, half cell potential and corrosion area ratio, the degree of steel corrosion can be assumed.

  • PDF

A Study on the Corrosion Characteristics of Steel Reinforcements Induced by Internal Chlorides in Concrete (콘크리트 내부염소이온에 의한 철근의 부식특성에 관한 연구)

  • 오병환;장승엽;신용석;차수원;김광수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.197-202
    • /
    • 1998
  • The corrosion of steel reinforcements in concrete is of much concern in recent years. The mechanism of corrosion, however, is not clear yet. This study is focused on the corrosion of steel induced by internal chlorides in concrete at early ages. To examine the critical concentration of steel, half-cell potential, chemical composition of expressed pore solutions of mortars and rate of corrosion area were observed with respect to additions of chlorides, types of binders, water-binders ratio.

  • PDF

A Study on Corrosion Resistance of Reinforced Concrete Structures using Natural Inorganic Minerals (천연 무기 광물계 혼화재료를 혼입한 철근콘크리트 구조물의 부식저항성에 관한 연구)

  • Tae, Sung Ho;Park, Jae Young;Kim, Jae Young;Park, Jae Seung;Kyung, Je Woon;Nam, Ho Yoon
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.127-133
    • /
    • 2007
  • As a fundamental study on the corrosion resistance of reinforced concrete structures using Natural Inorganic Minerals exposed to carbonation environment, The test specimens were concrete(W/C=60%) with Natural Inorganic Minerals content of 0%, 10%. Accelerated carbonation and autoclave corrosion accelerated curing were then conducted with them. The corrosion resistance of steel in concrete with Natural Inorganic Minerals content of 0%, 10% was examined by corrosion form, half-cell potential, polarization resistance, corrosion area and weight loss after 24 hours of autoclave corrosion accelerated curing.The results of the study showed that as for steel in concrete with Natural Inorganic Minerals content of 10%, the corrosion resistance was more excellent than steel in concrete with Natural Inorganic Minerals content of 0%.

Effect of Specimen Area on the Corrosion Rate of Low Alloy Steel (저합금강의 부식속도에 미치는 시편 면적의 영향)

  • Kim, Min-Jun;Jang, Young-Wook;Yoo, Yun-Ha;Kim, Jong-Jip;Kim, Jung-Gu
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.2
    • /
    • pp.96-102
    • /
    • 2010
  • Effects of specimen area on the corrosion rate of low alloy steel were studied in sulfuric acid solution. The corrosion behavior of specimen was tested by electrochemical impedance spectroscopy (EIS), linear polarization resistance measurement (LPR) and potentiodynamic polarization measurement. The surface was analyzed by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and electron probe X-ray micro analyzer (EPMA). As surface area was increased, corrosion rate was increased by the effect of small anode-large cathode.

Corrosion of rebar in carbon fiber reinforced polymer bonded reinforced concrete

  • Bahekar, Prasad V.;Gadve, Sangeeta S.
    • Advances in concrete construction
    • /
    • v.8 no.4
    • /
    • pp.247-255
    • /
    • 2019
  • Several reinforced concrete structures that get deteriorated by rebar corrosion are retrofitted using Carbon Fiber Reinforced Polymer (CFRP). When rebar comes in direct contact with CFRP, rebar may corrode, as iron is more active than carbon. Progression of corrosion of rebar in strengthened RC structures has been carried out when rebar comes in direct contact with CFRP. The experimentation is carried out in two phases. In phase I, corrosion of bare steel bar is monitored by making its contact with CFRP. In phase II, concrete specimens with surface bonded CFRP were casted and subjected to the realistic exposure conditions keeping direct contact between rebar and CFRP. Progression of corrosion has been monitored by various parameters: Half-cell potential, Tafel extrapolation and Linear Polarisation Resistance. On termination of exposure, to find residual bond stress between rebar and concrete, pull-out test was performed. Rebar in contact with CFRP has shown substantially higher corrosion. The level of corrosion will be more with more area of contact.

Rebar corrosion effects on structural behavior of buildings

  • Yuksel, Isa
    • Structural Engineering and Mechanics
    • /
    • v.54 no.6
    • /
    • pp.1111-1133
    • /
    • 2015
  • Rebar corrosion in concrete is one of the main causes of reduction of service life of reinforced concrete buildings. This paper presents the influence of rebar corrosion on the structural behavior of reinforced concrete (RC) buildings subjected to strong earthquake ground motion. Different levels of rebar corrosion scenarios were applied on a typical four story RC frame. The deteriorated conditions as a result of these scenarios include loss in cross-sectional area and loss of mechanical properties of the reinforcement bars, loss in bond strength, and loss in concrete strength and its modulus of elasticity. Dynamic analyses of the frame with different corrosion scenarios are performed with selected strong earthquake ground motion records. The influences of degradation in both concrete and reinforcement on structural behavior are investigated by comparing the various parameters of the frame under different corrosion scenarios with respect to each other. The results show that the progressive deterioration of the frame due to rebar corrosion causes serious structural behavior changes such as change in failure mode. The intensity, propagation time, and extensity of rebar corrosion have very important effects on the level of degradation of steel and concrete, as well as on the earthquake behavior of the structure.

An Electrochemical Study on the Effect of Post-Weld Heat Treatment about Corrosion Resistance Property of SS400 Steel for Ship`s Materials (선박재료용 SS400강의 내식성에 대한 용접후 열처리효과에 관한 전기화학적 연구 (II))

  • 김성종;김진경;문경만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.58-68
    • /
    • 2000
  • When SS400 steel was welded with low hydrogen type and ilmennite type welding, the effect of post-weld heat treatment(PWHT) was investigated with parameters such as micro vickers hardness, corrosion potential, polarization behaviors, galvanic current, Al anode generating current and Al anode weight loss etc. Hardness of each parts(HAZ, BM, WM) by PWHT in case of low hydrogen type and ilmennite type welding was lower than that of each parts by As-welded However hardness of WM area in case of low hydrogen type and ilmennite type welding was the highest among those three parts regardless of PWHT, Whereas in case of ilmennite type welding, WM area was the highest potential among these three parts on galvanic potential series with As-welded while BM area was the highest potential among these three parts by PWHT on the contrary. And in case of low hydrogen type welding, galvanic corrosion and micro cell corrosion of welding parts was decreased with PWHT. However, It was increased with PWHT in case of ilmennite type welding. Moreover Al anode generating current and anode weight loss in case of low hydrogen type was decreased by PWHT compared to As-wedled but, which was increased than that of As-welded in case of ilmennite type welding. Therefore, it is suggested that Corrosion resistance property in case of low hydrogen type welding is increased by PWHT. However its property was devreased with PWHT in case of ilmennite type welding.

  • PDF

Cu Corrosion Test Method for Lead-Free Solders (무연솔더 동판부식 시험법 연구)

  • Kim, Mi-Song;Hong, Won Sik;Oh, Chul Min;Kim, Keun-Soo
    • Journal of Welding and Joining
    • /
    • v.35 no.3
    • /
    • pp.21-27
    • /
    • 2017
  • A soldering temperature of ($235{\pm}3$) $^{\circ}C$ is described in ISO 9455-15 for the copper corrosion test. However, this temperature is not suitable for performing lead-free solder pastes. We evaluated the compatibility of a lead-free solder paste in the experimental conditions of (Liquidus temperature + ($35{\pm}3$)) $^{\circ}C$. Based on the results after a Cu corrosion test, a proper temperature for Pb-free soldering was (melting point+($35{\pm}3$)) $^{\circ}C$. Criteria used to evaluate corrosion due to discoloration of flux residue is described in ISO 9455-15, but a more quantitative evaluation standard is needed. In this study, experimental error level was estimated by analyzing flux residue after a corrosion test for 72, 500 hours of specimens using EDS analysis with acceleration voltage. It was determined that the copper area at the flux residue boundary is suitable for the EDS analysis area.

Assessment of Atmospheric Corrosivity at Jeju Island (제주도 대기환경의 부식성 평가)

  • KIM GUI-SHIK;YANG KYEONG-CHO;HU CHUL-GOO;SONG JEONG-HWA
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.253-259
    • /
    • 2004
  • The Jeju Island in Korea is the clean area which the tradition culture is preserved locally well with the nature environment of Heaven's blessing. An air pollution is becoming recently serious problem as the industrial development is proceeded with the urbanization. This study investigates that the atmosphere environment at Jeju area influences on the metal corrosion. A study of the atmosphere corrosion for carbon steel, copper, zinc ana aluminium exposed on five test sites indoors and outdoors. Corrosion results are treated statistically and adjusted to a model previously proposed for carbon steel, copper, zinc and aluminium based on the influence of environmental parameters and main pollutants($SO_2$ and chlorides) on tire atmosphere corrosion of metals. Through this study, we try to set the standards atmosphere corrosion at Jeju Island.

  • PDF