• Title/Summary/Keyword: corrosion area

Search Result 571, Processing Time 0.027 seconds

Seismic performance assessment of deteriorated reinforced concrete columns using a new plastic-hinge element

  • Tae-Hoon Kim;Hosung Jung
    • Computers and Concrete
    • /
    • v.32 no.2
    • /
    • pp.139-148
    • /
    • 2023
  • The purpose of this paper is to numerically assess the seismic performance of deteriorated reinforced concrete columns using a new plastic-hinge element. Developing a three dimensional (3D) nonlinear model can be difficult and computationally complex, and there can be problems applying it in the field. Thus, to solve these problems, a plastic-hinge element that could considers the shear deformation of deteriorated reinforced concrete columns was proposed. The developed element was based on the Timoshenko beam model and used two nodes with six degrees of freedom and a zero-length element. Moreover, the developed model could consider the combined effects of corrosion, as demonstrated by the reduced reinforcement area and the loss of bond. Consequently, the numerical procedures developed for evaluating the seismic performance of deteriorated columns were validated by comparing the verification results.

Mass Loss and Surface Passivation Characteristics of Electropolished SLM 316L Steel (전해연마된 SLM 기반 316L Steel의 질량 손실 및 표면 피복 특성 연구)

  • Jothi Prakash Chakrapani Gunarasan;Dong-Gyu Ahn;Jeong-Won Lee
    • Transactions of Materials Processing
    • /
    • v.33 no.4
    • /
    • pp.255-260
    • /
    • 2024
  • Utilization of additively manufactured parts in intended applications is limited by surface roughness. Roughness reduction in internal surface area of AM parts is exponentially more challenging. Reported methodologies for roughness reduction, result in material loss and limits the operational life of these parts. Herein, we explored electropolishing to reduce surface roughness of SLM manufactured 316L steel. Furthermore, the mass loss incurred during electropolishing is deduced as a function of polishing time. The change in roughness, wettability and surface passivation were studied and discussed in detail.

EFFECT OF POWDER SHAPE AND SINTERING TEMPERATURE ON THE PREPARATION OF Ni-BASED POROUS METAL

  • YU-JEONG YI;MIN-JEONG LEE;HYEON-JU KIM;SANGSUN YANG;MANHO PARK;BYOUNG-KEE KIM;JUNG-YEUL YUN
    • Archives of Metallurgy and Materials
    • /
    • v.64 no.3
    • /
    • pp.917-920
    • /
    • 2019
  • Usually porous metals are known as relatively excellent characteristic such as large surface area, light, lower heat capacity, high toughness and permeability for exhaust gas filter, hydrogen reformer catalyst support. The Ni alloys have high corrosion resistance, heat resistance and chemical stability for high temperature applications. In this study, the Ni-based porous metals have been developed with Hastelloy powder by gas atomization and water atomization in order to find the effects of powder shape on porous metal. Each Hastelloy powder is pressed on disk shape of 2 mm thickness with 12 tons using uniaxial press machine. The specimens are sintered at various temperatures in high vacuum condition. The pore properties were evaluated using Porometer and microstructures were observed with SEM.

Study on Improvement of Surface Properties of SKD61 Powder on S45C Using Laser Cladding

  • Cheol-Woo Kim;Hyo-Sang Yoo
    • Archives of Metallurgy and Materials
    • /
    • v.67 no.4
    • /
    • pp.1465-1468
    • /
    • 2022
  • In this study, we investigated the effect of cladding on structural carbon steel (S45C) using 5%Cr-1.5%Mo-Fe powder (SKD61), which is expected to show economically efficient production of die-casting parts. The process conditions were performed under argon atmosphere using a diode laser source with specialized wavelength of 900-1070 nm, and the output conditions were 3, 4, and 5 kW, respectively. After the cladding was completed, the surface coating layer's shape and the microstructure were analyzed. The hardness test was carried out with Micro Vickers hardness tester under 500 gram-force along the normal line at the interval of 0.2 mm from the surface to core direction on the cross-sectional area. In addition, polarization curve test of the surface coating layer was performed to investigate the corrosion resistance characteristics.

Effect of Final Annealing Temperature on Precipitate and Oxidation of Zr- Nb Alloys (Zr-Nb계 합금의 석출물 특성과 산화 특성에 미치는 마지막 열처리 온도의 영향)

  • Yun, Yeong-Gyun;Jeong, Yong-Hwan;Park, Sang-Yun;Wi, Myeong-Yong
    • Korean Journal of Materials Research
    • /
    • v.11 no.8
    • /
    • pp.647-654
    • /
    • 2001
  • Effects of final annealing temperature on the precipitate and oxidation were investigated for the Zr-lNb and Zr-lNb-lSn-0.3Fe alloys. The microstructure and oxidation of both alloys were evaluated for the optimization of final annealing process of these alloys in the annealing temperature regime of 450 to $800^{\circ}C$. The corrosion test was performed under steam at $400^{\circ}C$ for 270 days in a static autoclave. The oxide formed was identified by low angle X-ray diffraction method. The $\beta$-Zr was observed at annealing temperature above $600^{\circ}C$. Above $600^{\circ}C$, the precipitate area volume fraction of Zr-lNb and Zr-1Nb-lSn-0.3Fe alloys appeared to be increased with increasing the final annealing temperature. The corrosion resistance of Zr-lNb was higher than that of Zr- lNb-lSn-0.3Fe alloy. The corrosion rate of both alloys were accelerated due to the formation and growth of $\beta$-Zr with increasing the annealing temperature.

  • PDF

A STUDY CONCERNING THE CHARACTERISTICS OF KOREAN NI-TI ALLOY ORTHODONTIC WIRE (국산 Ni-Ti합금 교정용 선재의 특성에 관한 연구)

  • Park, Dong-Ok;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.187-200
    • /
    • 1995
  • To estimate the characteristics of Korean Ni-Ti alloy orthodontic wire, this study investigated compositions, tensile properties, bending properties, heat treatment effects, and ion releasing degrees, and compared these characteristics to those of the imported Ni-Ti alloy wire. The results obtained are as follows ; 1. Ti and -Ni elements in ORTHOLLOY were in a range showing superelasticity, and there was a little difference in the Ni and Ti contents of ORTHOLLOY as compared with those of SENTALLOY. 2. The results of the tensile test concerning ORTHOLLOY exhibited a superelastic effect, indicating an area of a definite amount of stress in spite of the changes in the range from $2\%\;to\;8\%$ in the strain rate. 3. ORTHOLLOY presented higher load values than SENTALLOY in the same deflection values when the wire was tested in three-point bending. A load range displaying a superelastic effect was 80-l00g, 140-l80g, and 130-200g respectively, in wire diameters of 0.014', 0.016', and 0.018' 4. By heat treatments at $400^{\circ}C$ and at $500^{\circ}C$, a load range showing the effect of superelasticitly was lessened by the duration of the heat treatment time. The superelastic effect was destroyed as a result of the 10 minutes heat treatment at $600^{\circ}C$. 5. The quantity of the Ni ion released from ORTHOLLOY, tended to be greater than the amount of released Ni ion in SENTALLOY. The Co ion released was very little(<0.01ppm) in SENTALLOY and ORTHOLLOY irrespective of the lapse of time. Released Ni ions on the 1st day were at the maximum, and the releasing rate showed plateaus after three days. 6. The surface morphology of SENTALLOY was relatively regular irrespective of the lapse of rime, and the corrosion tendency was not observed. However, the surface morphology of ORTHOLLOY was rather irregular and shelved fitting corrosion after immersion.

  • PDF

Prediction of Time to Corrosion for Concrete Bridge Decks Exposed to De-Icing Chemicals (제빙화학제 살포로 인한 콘크리트 교량 바닥판의 철근부식 시작시기의 예측)

  • Lee, Chang-Soo;Yoon, In-Seok;Park, Jong-Hyok
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.606-614
    • /
    • 2003
  • The major cause of deterioration for the concrete bridge decks exposed to de-icing chemicals would be chloride-induced reinforcement corrosion. Thus, in this paper, in order to predict time to corrosion for concrete bridge decks in the urban area, chloride concentration was measured with depth from the surface. A frequency analysis on surface chloride concentration and chloride diffusion coefficient of concrete bridge deck equals 0.192, 29.828 in the scale parameter and 7.899, 1.983 in the shape parameter of gamma distribution. The average value of surface chloride concentration equals 1.5 kg/㎥ and condenses from 1 to 2 kg/㎥ in the level of probability 70%. From the probabilistic results, it is confirmed that 26mm of minimum cover depth in order to target 20 years over is calculated. The countermeasure strategy to extend the service life of concrete bridge deck exposed to de-icing chemicals would be an effective method to increase cover depth and to place high performance concrete, which could lead to reduce the chloride diffusion coefficient and distribution range.

Application of Laser Ultrasonic Technique for Nondestructive Evaluation of Wall Thinning in Pipe (배관부 감육 손상의 비파괴 평가를 위한 레이저 초음파 기술 적용)

  • Hong, Kyung-Min;Kang, Young-June;Park, Nak-Kyu;Yoon, Suk-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.361-367
    • /
    • 2013
  • Many of the nuclear power plant pipe is used in high temperature and high pressure environment. Wall thinning frequently caused by the corrosion. These wall thinning in pipe is expected gradually increase as nuclear power become superannuated. Therefore there is need to evaluate wall thinning in pipe and corrosion defect by non-destructive method to prevent the accident of the nuclear power facility due to pipe corrosion. Especially for real-time assessment of the wall thinning that occurs in nuclear power plant pipe, the laser ultrasonic technology can be measured even in hard-to-reach areas, beyond the limits of earlier existing contact methods. In this study, the optical method using laser was applied for non-destructive and non-contact evaluation. Ultrasonic signals was acquired through generating ultrasonic by pulse laser and using laser interferometer. First the ultrasonic signal was detected in no wall thinning in pipe, then a longitudinal wave velocity was measured inside of pipe. Artificial wall thinning specimen compared to 20, 30, 40 and 50% of thickness of the pipe was produced and the longitudinal wave velocity was measured. It was possible to evaluate quantitatively the wall thinning area(internal defect depth) cause it was able to calculate the thickness of each specimen using measured longitudinal wave velocity.

Hot Corrosion Behavior of Plasma Sprayed 4 mol% Y2O3-ZrO2 Thermal Barrier Coatings with Volcanic Ash (플라즈마 용사법으로 제작된 4mol% Y2O3-ZrO2 열차폐코팅의 화산재에 의한 고온열화거동)

  • Lee, Won-Jun;Jang, Byung-Koog;Lim, Dae-Soon;Oh, Yoon-Suk;Kim, Seong-Won;Kim, Hyung-Tae;Araki, Hiroshi;Murakami, Hideyuki;Kuroda, Seiji
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.6
    • /
    • pp.353-358
    • /
    • 2013
  • The hot corrosion behavior of plasma sprayed 4 mol% $Y_2O_3-ZrO_2$ (YSZ) thermal barrier coatings (TBCs) with volcanic ash is investigated. Volcanic ash that deposited on the TBCs in gas-turbine engines can attack the surface of TBCs itself as a form of corrosive melt. YSZ coating specimens with a thickness of 430-440 ${\mu}m$ are prepared using a plasma spray method. These specimens are subjected to hot corrosion environment at $1200^{\circ}C$ with five different duration time, from 10 mins to 100 h in the presence of corrosive melt from volcanic ash. The microstructure, composition, and phase analysis are performed using Field emission scanning electron microscopy, including Energy dispersive spectroscopy and X-ray diffraction. After the heat treatment, hematite ($Fe_2O_3-TiO_2$) and monoclinic YSZ phases are found in TBCs. Furthermore the interface area between the molten volcanic ash layers and YSZ coatings becomes porous with increases in the heat treatment time as the YSZ coatings dissolved into molten volcanic ash. The maximum thickness of this a porous reaction zone is 25 ${\mu}m$ after 100 h of heat treatment.

Hydrogeological Characteristics of Seawater Intrusion in the Coastal Area (임해지역 주변에서의 해수침투특성)

  • 김천수;김경수;배대석;송승호
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.2
    • /
    • pp.61-72
    • /
    • 1997
  • With increasing activities for groundwater withdrawal and for the construction of underground cavern in the coastal areas, the seaward flow of groundwater has been disturbed or even reversed, resulting in seawater intrusion in aquifers. This phenomenon would be attributed to the freshwater contamination and the corrosion of steel materials. The hydrogeological and geochemical investigations have performed to characterize the seawater intrusion into the underground caverns located in the coastal area. Assumimg the inland aquifer as unconfined one, we have found out that the theoretical interface of freshwater-seawater is far different from the pathways identified. In the study site, the main pathways of seawater intrusion into the underground cavern are characterized as the sub-horizontal fractures (zones). The seawater intrusion in granitic terrane would depend mainly on the characteristics of conductive fracture system developed along the coastal area.

  • PDF