Electrolytic Corrosion Protection Methods of Depots using Silicon Rectifier for the Rail (귀선자동개폐장치를 이용한 차량기지 전식방지법)

  • Lee, H.G.;Ha, Y.C.;Ha, T.H.;Choi, J.H.;Kim, D.K.;Bae, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.211-213
    • /
    • 2007
  • Current of DC traction systems flows from the positive busbar of the substation, through the overhead contact system, to the vehicle, and returns through the running rails. Because the rails are not very effectively insulated from the earth a certain amount of current flows into the earth, especially in the area near the load and depots. At the place where the stray current leaves the rail and pipe, corrosion may take place. In this paper we introduce the electrolytic corrosion protection methods of depots using silicon rectifier for the rail.

  • PDF

Strength Evaluation of Aluminum Alloy Bolt by Nano-Indentation Hardness Test

  • KUBOTA Yoshihiro;NAKAMURA Tamotsu;KOBAYASHI Mitsuo;FUKUDA Katsumi
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10b
    • /
    • pp.123-126
    • /
    • 2003
  • A high strength aluminum alloy bolt (A7050, T7 temper treatment) has been developed by the authors. The bolt has a small grain size in the whole area of the bolt because of the large equivalent strain followed by thermo-mechanical treatment. As the bolt made of A 7050 has a risk of stress corrosion cracking, each grain should be strengthened the grain inside than the grain boundary in order to improve the stress corrosion cracking resistance. It has been confirmed that the nano-indentation hardness at each grain inside increased with the increasing equivalent strain by thermo-mechanical treatment processing.

  • PDF

A Study on the Relief of Shell Wall Thinning of Low Pressure Type Feedwater Heater Around the Extraction Nozzle Identified (저압형 급수가열기 추기노즐에서 동체 감육 완화에 관한 연구)

  • Kim, Kyung-Hoon;Hwang, Kyeong-Mo;Seo, Hyuk-Ki
    • Journal of ILASS-Korea
    • /
    • v.13 no.4
    • /
    • pp.173-179
    • /
    • 2008
  • The current machinery and tools of secondary channel of the nuclear power plants were produced in the carbon-steel and low-alloy steel. What produced with the carbon-steel occurs wall thinning effect from flow accelerated corrosion by the fluid flow at high temperature, high pressure. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle-installed. Wall thinning by flow accelerated corrosion occurs piping system, the heat exchanger, steam condenser and feedwater heaters etc,. Feedwater heaters of many nuclear power plants have recently experienced sever wall thinning damage, which will increase as operating time progress. This study describes the comparisons between the numerical results using the FLUENT code and experimental data of down scale model.

  • PDF

Reference Electrode for Monitoring Cathodic Protection Potential

  • Panossian, Z.;Abud, S.E.
    • Corrosion Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.227-234
    • /
    • 2017
  • Reference electrodes are generally implemented for the purpose of monitoring the cathodic protection potentials of buried or immersed metallic structures. In the market, many types of reference electrodes are available for this purpose, such as saturated calomel, silver/silver chloride and copper/copper sulfate. These electrodes contain a porous ceramic junction plate situated in the cylindrical body bottom to permit ionic flux between the internal electrolyte (of the reference electrode) and the external electrolyte. In this work, the copper/copper sulfate reference electrode was modified by replacing the porous ceramic junction plate for a metallic platinum wire. The main purpose of this modification was to avoid the ion copper transport from coming from the inner reference electrode solution into the surrounding electrolyte, and to mitigate the copper plating on the coupon surfaces. Lab tests were performed in order to compare the performance of the two mentioned reference electrodes. We verified that the experimental errors associated with the measurements conducted with developed reference electrode would be negligible, as the platinum surface area exposed to the surrounding electrolyte and/or to the reference electrolyte are maintained as small as possible.

Effect of the corrosion of plate with double cracks in bonded composite repair

  • Berrahou, Mohamed;Salem, Mokadem;Mechab, B.;Bouiadjra, B. Bachir
    • Structural Engineering and Mechanics
    • /
    • v.64 no.3
    • /
    • pp.323-328
    • /
    • 2017
  • This paper presents a three-dimensional finite element method analysis of repairing plate with bonded composite patch subjected to tensile load. The effect of the corrosion on the damage of the adhesive (FM73) in the length of two horizontal cracks on the both sides is presented. The obtained results show that the crack on the left side creates a very extensive area of the damaged zone and gives values of the stress intensity factor (SIF) higher than that on the right side. We can conclude that the left crack is more harmful (dangerous) than that on the right side.

Effect of Boundary Conditions on Failure Probability of Buried Steel Pile (매설된 강 파일의 경계조건이 파손확률에 미치는 영향)

  • 이억섭;편장식;김의상
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.4
    • /
    • pp.204-213
    • /
    • 2003
  • A survey for finding corrosion examples was performed on the underground steel piles buried for 19 years in the area of iron and steel making factory near Young-il bay. A failure probability model, which can be used to check the reliability of the corrosive mechanical element, based on Von-Mises failure criterion and the standard normal probability function is proposed. The effects of varying boundary conditions such as temperature change, soil-friction, internal pressure, earthquake, loading of soil, traffic loads and corrosion on failure probability of the buried steel piles are systematically investigated. To allow for the uncertainties of the design variables, a reliability analysis technique has been adopted; this also allows calculation of the relative contribution of the random variables and the sensitivity of the failure probability.

A Study on the Ultimate Compressive Strength of Ship Plate with Local Corrosion (국부이상부식을 가진 선체판의 압괴강도에 관한 연구)

  • 고재용;남정길
    • Journal of the Korean Institute of Navigation
    • /
    • v.22 no.3
    • /
    • pp.65-72
    • /
    • 1998
  • The use of high tensile steel plates is increasing in the fabrication of ship and offshore structures. In usual, plate element contributes to inplane stiffness against the action of inplane load. If the plate element has local corrosion, its load carrying capacity under inplane load is expected to be reduced. Until now, however, the research report concerned with this topic has not seen. In this study, a basic study which clarifies the influence of local corrosion on the ultimate collapse strength of plate element subjected to axial compression is carried out by using elasto-platic large deformation finite element analysis. In particular, influence of corrosive area, corrosive thickness and slenderness ratio of dented plate is investigated.

  • PDF

Fracture Toughness Evaluation of Natural Gas Pipeline under the Cathodic Protection

  • Kim, Cheol-Man;Baek, Jong-Hyun;Kim, Young-Pyo;Kim, Woo-Sik
    • Corrosion Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.133-138
    • /
    • 2009
  • For the corrosion protection of the natural gas transmission pipelines, two methods are used, cathodic protection and coating technique. In the case of cathodic protection, defects are embrittled by occurring hydrogen at the crack tip or material surface. It is however very important to evaluate whether cracks in the embrittled area can grow or not, especially in weld metal. In this work, on the basis of elastic plastic fracture mechanics, we performed the CTOD testing with various test conditions, such as testing rate and potential. The CTOD of the base metal and the weld metal showed a strong dependence of the test conditions. The CTOD decreased with decreasing testing rate and with increasing cathodic potential. The morphology of the fracture surface showed the quasi-cleavage at low testing rate and cathodic overprotection. The low CTOD was caused by hydrogen embrittlement at crack tip.

Characterization of Air and SO2 Gas Corrosion of Silicon Carbide Nanofibers (탄화규소 나노섬유의 고온 대기 및 SO2 가스분위기에서의 부식물성)

  • Kim, Min-Jung;Lee, Dong-Bok
    • Journal of Surface Science and Engineering
    • /
    • v.43 no.1
    • /
    • pp.36-40
    • /
    • 2010
  • The SiO vapor that was generated from a mixture of Si and $SiO_2$ was reacted at $1350^{\circ}C$ for 2 h under vacuum with carbon nanofibers to produce SiC nanofibers having an average diameter of 100~200 nm. In order to understand the gas corrosion behavior, SiC nanofibers were exposed to air up to $1000^{\circ}C$. SiC oxidized to amorphous $SiO_2$, but its oxidation resistance was inferior unlike bulk SiC, because of high surface area of nanofibers. When SiC nanofibers were exposed to Ar-1% $SO_2$ atmosphere, SiC oxidized to amorphous $SiO_2$, without forming $SiS_2$, owing to the thermodynamic stability of $SiO_2$.

Corrosion Resistance of Stainless Steels Analyzed by Fractal Geometry

  • Kim, Eun-Ji;Park, Su-Jin;Heo, Jung-Ho;Shin, Heon-Cheol
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.2
    • /
    • pp.112-116
    • /
    • 2010
  • Fractal property of the passivated steel surface was investigated on the basis of scaling analysis with a special focus on its relationship with corrosion resistance. For this purpose, the surface of stainless steel was intentionally oxidized under a variety of passivation conditions and its scaling property was analyzed by a triangulation method. The morphology of the passivated steel surface was satisfactorily evaluated with fractal dimension. From the chronoamperometry and impedance measurement, it proved that lower fractal dimension leads to more enhanced corrosion resistance. The higher passivity of the steel surface with lower fractal dimension was discussed in terms of active area and structural imperfection.