• Title/Summary/Keyword: corrosion area

Search Result 571, Processing Time 0.025 seconds

Corrosion Resistance of Cr-bearing Rebar in Concrete Subjected to Carbonation and Chloride Attack (중성화와 염해의 복합 열화 환경하의 콘크리트 내에서의 Cr강방식철근의 방식성)

  • Tae, Sung-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.115-122
    • /
    • 2006
  • Ten types of steel bars having different Cr contents were embedded in concretes with chloride ion contents of 0.3, 0.6, 1.2, and $2.4kg/m^3$ to fabricate specimens assuming such deteriorative environments. After being carbonated to the reinforcement level, these concretes were subjected to corrosion-accelerating cycles of heating/cooling and drying/wetting. The time-related changes in the corrosion area and corrosion loss of the Cr-bearing rebars were then measured to investigate their corrosion resistance. The results revealed that in a deteriorative environment prone to both carbonation and chloride attack, corrosion resistance was evident with a Cr content of 7% or more and 9% or more in concretes with chloride ion contents of 1.2 and $2.4kg/m^3$, respectively.

Crevice Corrosion Evaluation of Cold Sprayed Copper (저온분사코팅구리의 틈새부식 특성 평가)

  • Lee, Min-Soo;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.247-260
    • /
    • 2010
  • The developement of a HLW disposal canister is under way in KAERI using Cold Spray Coating technique. To estimate corrosion behavior of a cold sprayed copper, a creivice corrosion test was conducted at Southwest Research Institute(SWRI) in the United State. For the measurement of repassivation potential needed for crevice corrosion, three methods such as (1) ASTM G61-86 : Cyclic Potentiodynamic Polarization Measurements, (2) Potentiodynamic Polarization plus intermediate Potentiostatic Hold method, and (3) ASTM G192-08 (THE method) : Potentiodynamic- Galvanostatic-Potentiostatic Method, were introduced in this report. In the crevice corrosion test, the occurrence of corrosion at crevice area was optically determined and the repassivation potentials were checked for three kind of copper specimens in a simulated KURT underground water, using a crevice former dictated in ASTM G61-86. The applied electrochemical test techniques were cyclic polarization, potentiostatic polarization, and electrochemical impedance spectroscopy. As a result of crevice corrosion tests, every copper specimens including cold sprayed one did not show any corrosion figure on crevice areas. And the open-cell voltage, at which corrosion reaction initiates, was influenced by the purity of copper, but not their manufacturing method in this experiment. Therefore, it was convinced that there is no crevice corrosion for the cold sprayed copper in KURT underground environment.

A Study on the Rust-protection Performance of Concrete using Ground Granulated Blast-furnace Slag (고로슬래그 미분말을 사용한 콘크리트의 방청성능에 관한 연구)

  • Park, Sang-Joon;Kim, Dong-Seok;Won, Cheol;Lee, Sang-Soo;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.529-532
    • /
    • 2001
  • In this paper, rust-protection performance of concrete using ground granulated blast-furnace slag are discussed. 4 kinds of W/B in combination with 3 kinds of replacement ratio of ground granulated blast-furnace slag and 2 kinds of chloride ion contents of are selected as experimental parameters. According to the experimental results, as the replacement ratio of ground granulated blast-furnace slag is increased, the corrosion area of steel bar tends to be decreased. However, as the autoclave cycle and chloride ion contents are increased, the corrosion area of steel bar is increased. In conclusion, when the replacement ratio of ground granulated blast-furnace slag is 50%, the strength and rust-protection performance appear to be most excellent.

  • PDF

Effect of Ultrasound During Pretreatment on the Electrochemical Etching of Aluminum and Its Capacitance (초음파를 이용한 전처리가 알루미늄의 전기화학적 에칭 및 정전용량에 미치는 효과)

  • Jung, Insoo;Tak, Yongsug;Park, Kangyong;Kim, Hyungi;Kim, Sungsoo
    • Corrosion Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.37-42
    • /
    • 2011
  • Aluminum was electrochemically etched in acid solution and the surface area was magnified by the formation of etch pits. Etched aluminum was covered with a compact and dense dielectric oxide film by anodization and applied to the aluminum electrolytic capacitor electrode. Capacitance of aluminum electrolytic capacitor is closely related with surface area, which depends on size and number of etch pits. Size of etch pits need to be controlled because inside of the pits can be buried by the formation of dielectric oxide film. In this work, the effect of ultrasound pretreatment on the aluminum etch pit formation and capacitance were investigated. Additionally, the relationship between the second etching effect on pit size and capacitance was studied.

Evaluation of Piping Integrity in Thinned Main Feedwater Pipes

  • Park, Young-Hwan;Kang, Suk-Chull
    • Nuclear Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.67-76
    • /
    • 2000
  • Significant wall thinning due to flow accelerated corrosion(FAC)was recently reported in main feedwater pipes in 3 Korean pressurized water reactor(PWR) plants. The main feedwater pipes in one plant were repaired using overlay weld method at the outside of pipe, while those in 2 other plants were replaced with new pipes. In this study, the effect of the wall thinning in the main feedwater pipes on piping integrity was evaluated using finite element method. Especially, the effects of both the overlay weld repair and the stress concentration in notch-type thinned area on the piping integrity were investigated. The results are as follows : (1) The piping load carrying capacity may significantly decrease due to FAC. In special, the load carrying capacity of the main feedwater pipe was reduced by about 40% during about 140 months operation in Korean PWR plants. (2) By performing overlay weld repair at the outside of pipe, the piping load carrying capacity can increase and the stress concentration level in the thinned area can be reduced.

  • PDF

A Study on the Mechanical Characteristic in Al 6061 Alloys welded by Friction Stir Welding (Al 6061 합금의 마찰교반접합시 접합부의 역학적 특성에 관한 연구)

  • 방한서;김흥주;고민성;장웅성
    • Journal of Welding and Joining
    • /
    • v.20 no.3
    • /
    • pp.105-108
    • /
    • 2002
  • Al-alloy is utilized widely as a light-weight material to an automobile, a vessel and many kind of equipment, due to the light-weight and its characteristics that is a good tensile strength, elongation and tenacity for bearing heavy load and weight. Al-alloy has the good property of hot working, cold working and corrosion-resistant. But the exiting fusion welding by using Al has some economical and technical problems, but on the other hand, Friction Stir Welding (FSW) that is new joining method can settle the disadvantages that occur to the fusion welding and Is being applied and extended into the various industry fields. On this study, To analyze accurately the mechanical properties of joining area by FSW in Al 6061 alloy by using finite analysis program with finite element method. The size of HAZ and the thermal distribution is simulated and the mechanical properties around the FSW joining area to the Al-alloy 6061 is examined.

Probabilistic Assessment of life Time for Gas Pipe Lines (통계적 방법을 통한 가스배관의 잔여수명 예측)

  • Choe, B.H.;Lee, S.H.;Kim, Y.P.;Kim, W.S.;Ko, Y.T.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.234-239
    • /
    • 2004
  • A study on the probabilistic methodology for the estimation of the remaining life of Pressurized pipelines containing active corrosion defects is presented. This reliability assessment is earned out using extream value distribution of the corroded defects instead of already published failure perssure moded like NG18 or ASME B31G. The failure probability of pipelines depends on the number of corroded defects. and it could be calculated directly as the area exceeded a defined L V(Limited Value of corrosion depth). The remaining life of pressurized pipelines can also be estimated by the PDF of extream value distribution as calculating the exceeded area with a defined failure probability.

  • PDF

Evaluation of effective cross-area of reinforced concrete wall considering chloride diffusion using ANN

  • Hyeon-Keun Yang;Jun-Hee Park
    • Nuclear Engineering and Technology
    • /
    • v.56 no.10
    • /
    • pp.4254-4262
    • /
    • 2024
  • Reinforced concrete structures are subject to exposure to chloride ions in the air, leading to chloride penetration, and carbonation attacks resulting from exposure to carbon dioxide. This chemical degradation process induces corrosion of reinforcing bars within concrete, significantly impacting durability. Structures situated in coastal areas, such as nuclear power plants, are particularly susceptible to rapid chloride penetration due to the high chloride concentration in the air. This study utilizes existing experimental data to forecast the chloride diffusion coefficient employing artificial neural network (ANN technology). The total number of experimental data was 535 gathered from 18 papers. Through analysis of the chloride coefficient and predicted degradation depth, the effective cross-sectional area of concrete is examined, and the deterioration of wall performance is forecasted.

Mortality of Cigarette Beetle, Lasioderma serricorne, Fabricius (Coleoptera : Anobiidae) and Corrosion of Metals as Influenced by Sulfuryl fluoride ($SO_2F_2$) (훈증제 sulfuryl fluoride ($SO_2F_2$)의 궐련벌레(Lasioderma serricorne, Fabricius)에 대한 방제효과 및 몇 가지 금속류 성상에 미치는 영향)

  • Ohh, Myung-Hee;Sone, Jin;Chung, Kyu-Hoi
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.23 no.2
    • /
    • pp.141-148
    • /
    • 2001
  • Insecticidal effect or sulfuryl fluoride ($SO_2F_2$) to cigarette beetle, Lasiodema serricorne (F.), was studied in two different containers, one was 1m$^3$(without cardboard block) and the other was 0.5m$^3$(with cardboard block). Adults and larvae were transferred into a small metal can before placed in the containers. Each can was held for 8, 24, 48, 72, and 96 hours after $SO_2F_2$(10, 20, 30, and 40 g/$\ell$) treatment. All adults were killed in an 1m$^3$container. Larval mortality was 99 to 100% when the dosage of SO$_2$F$_2$was 10 and 20 g/$\ell$. Cardboard was attached between two 0.5m$^3$ containers ; one was fumigation area and the other was insect area. SO$_2$F$_2$ penetrated cardboard within 24 hours in most trials. $SO_2F_2$could affect all adults and larvae regardless of their susceptibility. All adults were killed at 8 hours in a 0.5m$^3$ container. But low mortality of larvae was recorded at 8 hours when small dosage was treated (30% in 10 g/$\ell$, 87.2% in 20 g/$\ell$). The mortality was increased as SO$_2$F$_2$ dosage increased. Six different metals (stainless, copper, brass, aluminum, iron, and zinc) were also tested to study metal corrosion and discoloration. No corrosion and discoloration was observed in most metals treated with $SO_2F_2$.

  • PDF

Study of Au-PTFE/Al Metallic bipolar plate for PEMFC (고분자 전해질형 연료전지용 Au-PTFE/Al 금속분리판 연구)

  • Yoo, Seung-Eul;Kim, Myong-Hwan;Goo, Young-Mo
    • New & Renewable Energy
    • /
    • v.3 no.1 s.9
    • /
    • pp.75-82
    • /
    • 2007
  • Aluminum was used as metallic bipolar plate material to reduce a stack weight. The functional materials such as conductive material, Au and nonconductive material, PTFE [polytetrafluoroethylene] were coated on the bipolar plate to enhance electrical contact and corrosion prevention in PEMFC. The active area of bipolar plate is divided into the top layer part that electric current mainly passes, and the bottom layer part that gas and water pass. The bottom layer part in the flow channel needs not to have electrical conductivity because it doesn't pass electric current directly. In this reason, Au on the top layer and PTFE on the bottom layer were coated to apply high electrical conductivity and/or good corrosion resistance. Although the single cell performance using Au-PTFE/Al bipolar plate was shown 78% in comparison with that of graphite, specific power of Au-PTFE/Al bipolar plate(0.4 W/g) was twice as much as graphite bipolar plate.

  • PDF