• Title/Summary/Keyword: correlation measurement

Search Result 3,277, Processing Time 0.031 seconds

Precise Measurement Method and Error Analysis with Roughness Variables for Estimation of Scattering Coefficients (지표면 산란 계수 예측을 위한 정확한 지표면 거칠기 변수 측정 방법 및 오차 분석)

  • Kweon, Soon-Koo;Hwang, Ji-Hwan;Oh, Yisok;Hong, Sungwook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.91-97
    • /
    • 2013
  • The input parameters of scattering models for computing the backscattering coefficients of earth terrains are mainly soil moisture and surface roughness. The backscattering coefficients of soil surfaces are more sensitive to surface roughness than soil moisture. In this study, we propose a precise measurement method for roughness parameters and analyze measurement errors. We measured surface roughness using a pin-board profiler(1 m, 0.5 cm interval) and a laser profiler(1 m, 0.25 cm interval). The measurement differences between two profilers in an average sense are 0.097 cm for root-mean-square (RMS) height and 1.828 cm for correlation length. The analysis of the correlation functions and relative errors shows that the laser measurements are more stable than the pin-board measurements. The differences of the calculated backscattering coefficients using a surface scattering model between pin-board and laser profiler measurements are less than 1 dB.

Development of a Computer Vision System to Measure Low Flow Rate of Solid Particles (컴퓨터 시각에 의한 고형 입자의 소량 유동율 측정장치 개발)

  • 이경환;서상룡;문정기
    • Journal of Biosystems Engineering
    • /
    • v.23 no.5
    • /
    • pp.481-490
    • /
    • 1998
  • A computer vision system to measure low flow rate of solid particles was developed and tested to examine its performance with various sized 7 kinds of seeds, perilla, mung bean, paddy, small red bean, black soybean, Cuba bean and small potato tuber. The test was performed for two types of particle flow, continuous and discontinuous. For the continuous flow tested with perilla, mung bean and paddy, the tests resulted correlation coefficients for the flow rates measured by the computer vision and direct method about 0.98. Average errors of the computer vision measurement were in a range of 6∼9%. For the discontinuous flow tested with small red bean, black soybean, Cuba bean and small potato tuber, the tests resulted correlation coefficients for the flow rates measured by the computer vision and direct method 0.98∼0.99. Average errors of the computer vision measurement were in a range of 5∼10%. Performance of the computer vision system was compared with that of the conventional optical sensor to count particles in discontinuous flow. The comparison was done with black soybean, Cuba bean and small potato tuber, and resulted that the computer vision has much better performance than the optical sensor in a sense of precision of the measurement.

  • PDF

Estimation of baroreflex sensitivity using pulse arrival time rather than systolic blood pressure measurement

  • Lee, Jong-Shill;Chee, Young-Joon
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.1
    • /
    • pp.14-19
    • /
    • 2010
  • Baroreflex sensitivity (BRS) is a parameter of the cardiovascular system that is reflected in changes in pulse interval (PD and systolic blood pressure (SBP). BRS contains information about how the autonomic nervous system regulates hemodynamic homeostasis. Normally the beat-to-beat SBP measurement and the pulse interval measured from the electrocardiogram (ECG) are required to estimate the BRS. We investigated the possibility of measuring BRS in the absence of a beat-to-beat SBP measurement device. Pulse arrival time (PAT), defined as the time between the R-peak of the ECG and a single characteristic point on the pulse wave recorded from any arterial location was measured by photoplethysmography. By comparing the BRS obtained from conventional measurements with our method during controlled breathing, we confirmed again that PAT and SBP are closely correlated, with a correlation coefficient of -0.82 to -0.95. The coherence between SBP and PI at a respiration frequency of 0.07-0.12 Hz was similar to the coherence between PAT and PI. Although the ranges and units of measurement are different (ms/mmHg vs. ms/ms) for BRS measured conventionally and by our method, the correlation is very strong. Following further investigation under various conditions, BRS can be reliably estimated without the inconvenient and expensive beat-to-beat SBP measurement.

Abdominal-Deformation Measurement for a Shape-Flexible Mannequin Using the 3D Digital Image Correlation

  • Liu, Huan;Hao, Kuangrong;Ding, Yongsheng
    • Journal of Computing Science and Engineering
    • /
    • v.11 no.3
    • /
    • pp.79-91
    • /
    • 2017
  • In this paper, the abdominal-deformation measurement scheme is conducted on a shape-flexible mannequin using the DIC technique in a stereo-vision system. Firstly, during the integer-pixel displacement search, a novel fractal dimension based on an adaptive-ellipse subset area is developed to track an integer pixel between the reference and deformed images. Secondly, at the subpixel registration, a new mutual-learning adaptive particle swarm optimization (MLADPSO) algorithm is employed to locate the subpixel precisely. Dynamic adjustments of the particle flight velocities that are according to the deformation extent of each interest point are utilized for enhancing the accuracy of the subpixel registration. A test is performed on the abdominal-deformation measurement of the shape-flexible mannequin. The experiment results indicate that under the guarantee of its measurement accuracy without the cause of any loss, the time-consumption of the proposed scheme is significantly more efficient than that of the conventional method, particularly in the case of a large number of interest points.

Frequency-Based Image Analysis of Random Patterns: an Alternative Way to Classical Stereocorrelation

  • Molimard, J.;Boyer, G.;Zahouani, H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.3
    • /
    • pp.181-193
    • /
    • 2010
  • The paper presents an alternative way to classical stereocorrelation. First, 2D image processing of random patterns is described. Sub-pixel displacements are determined using phase analysis. Then distortion evaluation is presented. The distortion is identified without any assumption on the lens model because of the use of a grid technique approach. Last, shape measurement and shape variation is caught by fringe projection. Analysis is based on two pin-hole assumptions for the video-projector and the camera. Then, fringe projection is coupled to in-plane displacement to give rise to 3D measurement set-up. Metrological characterization shows a resolution comparable to classical (stereo) correlation technique ($1/100^{th}$ pixel). Spatial resolution seems to be an advantage of the method, because of the use of temporal phase stepping (shape measurement, 1 pixel) and windowed Fourier transform (in plane displacements measurement, 9 pixels). Two examples are given. First one is the study of skin properties; second one is a study on leather fabric. In both cases, results are convincing, and have been exploited to give mechanical interpretation.

The Effect of the DIC Speckle Patterns for a Microcrack Measurement (미소균열 측정에 대한 DIC 스펙클 형상의 영향)

  • Lee, Jun Hyuk;Kwon, Oh Heon
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.4
    • /
    • pp.15-21
    • /
    • 2019
  • In order to secure the safety of various machinery, it is very important to develop a technique for accurately and quickly measuring the cracks generated in the mechanical equipment and evaluating the mechanical characteristics. The evaluation of the mechanical properties is accompanied by an appropriate strain measurement according to the material and crack occurrence of the target structure. Especially, when micro cracks are generated, the evaluation method is very important. Digital image correlation is an optical full field displacement measuring method which is using currently with speckles in the interested area. However the evaluation method and conditions of image distributions have to be considered carefully to measure the crack occurrence because the images of the speckle patterns affect the quality of displacement results. In this study, the speckle pattern density is characterized to improve the accuracy of the measurement method. And also the micro crack initiation is detected by the measured displacement in the adopted speckle pattern distribution. It is shown that the proposed method is useful to determine the density pattern distribution for the accurate measurement and crack detection.

A Study on the Classification of Brassiere Cups by Breast Volume Measurement Values on Women in their Twenties (20대 여성의 유방 부피 계측치에 따른 브래지어 컵의 분류)

  • Park, Yu-Sin;Kim, Seon-Mi;Kim, Eun-Ran
    • Journal of the Ergonomics Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.93-104
    • /
    • 2004
  • The research subjects of this study were 30 unmarried Korean women from 20 to 29 who had never had an operation on their breast. Measurement method using plaster breast mold was used for measuring their volume of breast. The correlation between their breast volume and the methods to set up brassiere cups with the existing method and with their circumference of breast was analyzed using KendalI's Coefficient. which was to figure out a method which had a bigger correlation with the volume of breast between the method to set up brassiere cups using the existing method and the method using the circumference of breast. The results analyzed showed that the coefficient of correlation between the existing method and the volume of breast was .12 and the significance level was .45. They didn't have any correlation. On the other hand. the coefficient of correlation between the circumference of breast and the volume of breast was .82. which was very high values and the significance level was very high .0001. Therefore. it turned out that it was difficult to set up brassiere cups by using the existing method and it was easier and more reliable to set up the cups by using the circumference of breast.

Sound Source Detection Technique Considering the Effects of Source Bandwidth and Measurement Noise Correlation (소음원 대역폭과 측정잡음의 상관관계를 고려한 소음원 탐지기법)

  • 윤종락
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.86-92
    • /
    • 2001
  • Various array processing techniques to identify the noise source position or bearing have been developed. Typical array processing techniques which are based on time delay between received signals at two sensors, are classified as conventional beamforming, correlation function and NAH (Near-Field Acoustic Holography) techniques which have their own characteristics with respect to application field and signal processing method. In this study, correlation function technique which could be applied for broadband noise source detection, is adopted and the effective detection technique is proposed considering the effects of source bandwidth and measurement noise correlation of noise sources. The validity of the Proposed technique is evaluated using the 3-dimensional nonlinear any which does not give 3-dimensional Position or bearing ambiguity

  • PDF

A Study on Body Measurement for Slacks Construction (Mainly with women's College Student in Seoul City Area) (Slacks 구성을 위한 인체계측 -서울특별시의 여대생을 중심으로-)

  • 김경자
    • Journal of the Korean Home Economics Association
    • /
    • v.17 no.2
    • /
    • pp.1-8
    • /
    • 1979
  • Recently, the Korean women has been steadily growing in number of wearing slacks , therefore the measurement data on lower part of body for slacks pattern construction have become needed. Thus, in order to obtain the measurement data, 304 of sophomore and junior classes form universities and colleges in Seoul city area were selected on purposed and , set to the object of study. In the course of measurement , thirteen items on lower part of body which is the basis of slacks pattern construction were measured, and then average balue, standard deviation and the mutual correlation were obtained.

  • PDF

Measurement of Varying Stimulus Evoked Otoacoustic Emission Latency Using cross Correlation (상호상관법을 이용한 가변 자극 유발이음향 방사파 잠시의 측정)

  • 최진영;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.19-22
    • /
    • 1991
  • Cross correlation method was newly applied for the calculation of latency of evoked otoacoustic emission. The latency was calculated froth the main peak of cross correlation function, which is one of Possible definition of latency. The output was also compared with those of conventional autocorrelation method. The results show that cross correlation method has better Performance than that of conventional method.

  • PDF