• Title/Summary/Keyword: correlation measurement

Search Result 3,277, Processing Time 0.031 seconds

Evaporation of a Water Droplet in High-Temperature Steam

  • Ban, Chang-Hwan;Kim, Yoo
    • Nuclear Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.521-529
    • /
    • 2000
  • A modified interfacial heat transfer correlation between a dispersed water droplet and ambient superheated steam is proposed and compared with available experimental data and other correlations. Modified one overcomes the inherent deficiencies of Lee and Ryley's interfacial heat transfer correlation that ignored the effects of steam superheating which can not be neglected especially in the reflood situation of a loss-of-coolant accident. Modified one is represented by (equation omitted) In the present correlation the effect of possible subcooling of a water droplet is not taken into consideration. Comparison of the above correlation with currently available measurement data for a water droplet in high temperature gas flow shows that the proposed one correlates well with the measurement data where the degree of superheating is negligible and considerable.

  • PDF

Measurement of Flow Field in a Ginseng Cleaner Model Using PIV (PIV에 의한 인삼세척기 모델 내부의 유동계측)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.139-145
    • /
    • 2001
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry) to high_speed flow characteristics within ginseng cleaner model. Three different kinds of flow rate(15. 20, 27l/min) are selected as experimental condition. Optimized cross correlation identification to obtain velocity distribution, time-mean velocity distribution, velocity, profile, kinetic energy and turbulence intensity are represented quantitatively for the deeped understanding of the flow characteristics in a ginseng cleaner model.

  • PDF

PIV Measurement and Flow Characteristics of Internal Flow Field within Ginseng Washing Machine (인삼세척기 내부유동장의 PIV계측 및 유동특성)

  • Na, Eun-Su;Song, Chi-Seong
    • 연구논문집
    • /
    • s.30
    • /
    • pp.59-65
    • /
    • 2000
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry)to high_speed flow characteristics within Ginseng washing machine. Three different kinds of flow rate(15,20,27 $\ell$/min)are selected as experimental conditions. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. Instantaneous velocity distribution, time-mean velocity distribution and velocity profiles are represented quantitatively at the full-scale region for the deeper understanding of the flow characteristics in Ginseng washing machine.

  • PDF

MLS for Building Acoustics Measurement (건축음향을 위한 MLS 측정방법)

  • Borjabad, Roberto
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.386-393
    • /
    • 1996
  • The paper describes how a Maximum Length Sequence(MLS) and correlation technique in the form of Hadamard transformation may be applied for the measurement of airborne sound reduction. It is shown that in most cases, the values obtained by the MLS technique will be equal to the expected values obtained by the classical method. However, due to the correlation process involved, the MLS method will be much less sensitive to disturbances from extraneous noise. The described method has been implemented in an RTA acoustic analyser.

  • PDF

The correlation of bone probing, radiographic and histometric measurements (골탐침과 방사선학적 및 조직학적 계측의 상관관계)

  • Hwang, Sung-Joon;Kim, Chang-Sung;Lee, Doug-Youn;Lee, Yong-Keun;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.4
    • /
    • pp.615-624
    • /
    • 2003
  • The most accurate method to assess bone level is the histometric measurement. However it causes discomfort in patients and damage to the regenerated tissues. in the present study, we used 4 type regenerative therapies, The present study evaluated the clinical reliability and accuracy of bone probing measurements and radiographic bone level in the assessment of bone level by comparing those results with histometric confirmed bone level. Twentyfour(24) intrabony defects(4${\times}$4mm 1-wall intrabony defects) were surgically created in the mandibular second and fourth premolars of 6 beagle dogs. The control group underwent a conventional flap operation. Experimental group I was treated with calcium phosphate glass only, and while experimental group 2 was treated with GTR and experimental group 3 was treated with calcium phosphate glass and GTR. The subjects were sacrificed 8 weeks after the operation and a bone probing measurements, radiographic measurement and histometric measurement was performed. The correlation between bone probing measurements(BP) and histometric measurement(HL), and radiographic measurement(RL) and histometric measurement(HL) were analyzed with Spearman's rank correlation analysis and the statistical significance with respect to the type of regenerative therapies was analyzed with the Kruskal Wallis test. The coefficient of correlation to HL was 0.73 for RL and 0.90 for BP. The type of regenerative therapies had no significant effect on the difference between HL and other measurements. The results of this study suggests that bone probing measurements most closely represents actual bone level. So bone probing measurements may be a good clinical method for assessing the hone level following any type of periodontal regenerative therapies.

Multi-point Dynamic Displacement Measurements of Structures Using Digital Image Correlation Technique (Digital Image Correlation기법을 이용한 구조물의 다중 동적변위응답 측정)

  • Kim, Sung-Wan;Kim, Nam-Sik
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.11-19
    • /
    • 2009
  • Recently, concerns relating to the maintenance of large structures have been increased. In addition, the number of large structures that need to be evaluated for their structural safety due to natural disasters and structural deterioration has been rapidly increasing. It is common for the structural characteristics of an older large structure to differ from the characteristics in the initial design stage, and changes in dynamic characteristics may result from a reduction in stiffness due to cracks on the materials. The process of deterioration of such structures enables the detection of damaged locations, as well as a quantitative evaluation. One of the typical measuring instruments used for the monitoring of bridges and buildings is the dynamic measurement system. Conventional dynamic measurement systems require considerable cabling to facilitate a direct connection between sensor and DAQ logger. For this reason, a method of measuring structural responses from a remote distance without the mounted sensors is needed. In terms of non-contact methods that are applicable to dynamic response measurement, the methods using the doppler effect of a laser or a GPS are commonly used. However, such methods could not be generally applied to bridge structures because of their costs and inaccuracies. Alternatively, a method using a visual image can be economical as well as feasible for measuring vibration signals of inaccessible bridge structures and extracting their dynamic characteristics. Many studies have been conducted using camera visual signals instead of conventional mounted sensors. However, these studies have been focused on measuring displacement response by an image processing technique after recording a position of the target mounted on the structure, in which the number of measurement targets may be limited. Therefore, in this study, a model experiment was carried out to verify the measurement algorithm for measuring multi-point displacement responses by using a DIC (Digital Image Correlation) technique.

Study about the Applicable Plan of GIS on Range of Magnetic Field Emitted from 60 Hz Powerline (60Hz 고압 송전선로의 자기장 발생범위에 대한 GIS 적용 방안에 대한 연구)

  • Hong, Seung Cheol;Choi, Seong Ho;Kim, Yoon Shin;Park, Jae Young
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.4
    • /
    • pp.271-277
    • /
    • 2006
  • In this study, we investigated the applicable plan of GIS on the environmental impact assessment of 60 Hz Powerline. So we assessed distance data based on calculations by use of 2D and 3D Geographical information systems(GIS) and distance data based on measurements on 1: 5000 maps accord with on site distance measurements to use input data for calculating magnetic field. One hundred eight of the on site measured addresses were selected from residences. The data were achieved by measuring the distance between residence and power line on maps with scales of 1: 5000. The digital map was obtained from National Geographic Information Institute with scales of 1: 5000, and we made 2D and 3D map. Correlation analyses were performed for statistical analyses. For the 3D GIS versus on site comparison of different exposure categories, 70 of 108 measurements were assigned to the correct category. Similarly for 2D GIS versus on site comparison, 71 of 108 were correctly categorized. When comparing map measurement with on site measurement, 62 of 108 were correctly categorized. When the correlation analysis was performed, best correlation was found between 3D GIS and on site measurements with r = 0.84947 (p<0.0001). The correlation between map and on site measurement yielded an r of 0.76517 (p<0.0001). Since the GIS measurements and map measurement were made from the center point in the building and the on site measurements had to be made from the closest wall on the building, this might introduce and additional error in urban areas. The difference between 2D and 3D calculations were resulted from the height of buildings.

Comparative Analysis of Anion Concentration by the Type of Roadside Buffer Green (가로변 완충녹지의 조성유형에 따른 음이온 농도 비교 분석)

  • Yoon, Yong-Han;Joo, Chang-Hun;Park, Hun;Kim, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1339-1347
    • /
    • 2014
  • This study were performed on roadside buffer green in Songpa-dong, Songpa-gu, Seoul in order to analyze the anion concentration according to the type of composition of roadside buffer green. Buffer green separating the physical structure of the measurement points and measurement locations were separated by roadside, green interior, the other side of the road. planting density and deposit of trees per each buffer green was measured in the order of mounding type> slope type> the plain type. If the measured temperature of the location-specific weather elements roadside> inside> the other side of the road in order of measurement and the temperature is lowered farther away from the road. If the relative humidity of the road on the other side> inside> the roadside in order to measure and this is the opposite of the temperature tendency. According to physical structure reduction of the temperature on the other side of the road and roadside in order of mounding type> the plain type> slope type was measured. As a result of measuring a anion therefore concentration of the anion inside of melt is in order of mounding type> the plain type> slope type, tended to match the melt characteristics. According to measured positions anion concentration is in the order of the other side of the road> inside> the roadside was measured. As a result of correlation analysis, in the case of measurement location-specific weather and anions the temperature is positive correlation, relative humidity is negative correlation and that's results of previous studies were supported.