Objective: To determine the correlation among three functional tests: single leg vertical jump (SLVJ), single leg hop for distance (SLHD), and single leg squat (SLSQ). Design: Cross sectional study. Methods: Twenty healthy men (n=10) and women (n=10) with no history of lower extremity dysfucntion participated in this study and performed in university research laboratory. The procedures consisted of a general warm-up, a task-specific warm-up, actual testing, and a cool down. All participants performed the three tests in random order. Each test was performed three times for the dominant and non-dominant lower extremity (LE). SLVJ, SLHD, SLSQ were measured using a standard tape measure. Results: Statistically significant difference was presented between dominant LE and non-dominant LE in each function test (p<0.05). The strongest correlation was between SLVJ and SLSQ, 0.939 and 0.883 for dominant and non-dominant LE, respectively (p<0.05). The weakest correlation was between SLVJ and SLHD, 0.713 for dominant (p<0.05) and between SLSQ and SLHD, 0.739 for non-dominant (p<0.05). Conclusions: There is a strong correlation between SLVJ and SLSQ, suggesting that each test measures similar constructs of function and can be substitutive, while weak correlation between SLSQ and SLHD suggest these two tests do not measure the same functional components and could be paired as outcome measures for the clinical assessment of LE function. It will provide physical therapist with scientific evidence for effective test combination of LE function assessment in clinical practice.
We study the transformed measures with respect to the real parameters of a self-similar measure on a self-similar Cantor set to give a simple proof for some result of its multifractal spectrum. A transformed measure with respect to a real parameter of a self-similar measure on a self-similar Cantor set is also a selfsimilar measure on the self-similar Cantor set and it gives a better information for multifractals than the original self-similar measure. A transformed measure with respect to an optimal parameter determines Hausdorff and packing dimensions of a set of the points which has same local dimension for a self-similar measure. We compute the values of the transformed measures with respect to the real parameters for a set of the points which has same local dimension for a self-similar measure. Finally we investigate the magnitude of the local dimensions of a self-similar measure and give some correlation between the local dimensions.
This paper propose a target tracker using phase correlation. The tracker consist of a pre-processing module, a translation estimation module based on phase correlation, a fine motion estimation module applied when confidence rate could not fulfill a threshold value and a reference image update module. The fine motion estimation module measure the shift, rotation and scale of input image compared to reference using Fourier-Mellin transform. Proposed tracker was tested its accuracy and robustness using some real indoor and outdoor image sequences.
Kim, Min-Seok;Jung, Seung-Hyun;Shin, Gil-Cho;Lee, Won-Chul
The Journal of Internal Korean Medicine
/
v.19
no.1
/
pp.97-113
/
1998
BACKGROUND The purpose of this study was to investigate disability of the patients after stroke, clinical applicability and usefulness of the FIM in evaluating the functional abilities and to assess the characteristics of the patients after stroke. And this study examined difference by predictive factors on the treatment outcome. METHOD The study was composed of 31 stroke patients who were within 1 week after stroke and had been treated in hospital more than 4 weeks. Improving rate was measured by using the Functional Independence Measure(FIM), and the correlation was analyzed between Motor FIM and Cognitive FIM. We analyzed significant meaning statistically in the mean value of FIM. RESULT 1. There was no significant meaning statistically in the mean value of FIM that was between both at admission and after 2 weeks. But there was proportional correlation between both at admission and after 4 weeks, and significant meaning statistically. 2. There was proportional correlation between both FIM and Motor FIM, and significant meaning statistically. But there was no significant meaning statistically between both FIM and Cognitive FIM. 3. There was no significant meaning statistically between both FIM and sex, age, side of weakness, stroke subtype, hypertension, hypercholesterolemia, diabetes mellitus, heart disease, starting point of rehabilitation therapy and past history of cerebral vascular accident. While dysarthria affected functional recovery in stroke patients, and significant meaning statistically. CONCLUSION 1. FIM appeared to be a valid and reliable method to measure the functional abilities of the patients after stroke. 2. Only one thing between Motor FIM and score didn't influence FIM score. 3. Dysarthria affected functional recovery in stroke patients, and it is the statistically significant factor.
This paper presents an overview analysis on the observed wind shear at Pohang Steel Works, focusing on diurnal patterns and the frequency of high nighttime shear at the site in case of land breeze. In addition, this paper discusses the importance of accurate shear estimates for reliable evaluation of wind energy density. In order for a long-term correlation of the site, three Measure-Correlate-Predict methods were tested with Pohang wind data and it was shown that the linear MCP gives poor estimation due to the geographic characteristics of complex terrain where the severe transformation of wind direction was accompanied.
This paper presents and overview analysis on the observed wind shear at Pohang Steel Works. focusing on diurnal patterns and the frequency of high nighttime shear at the site in case of land breeze. In addition, this paper discusses the importance of accurate shear estimation for reliable evaluation of wind energy density. In order for long-term correlation of the site, three Measure-Correlate-Predict methods were tested with Pohang wind data and it was shown that the linear MCP gives poor estimation due to the topological characteristics of complex terrain where the severe transformation of wind direction was accompanied.
Purpose : This study carried out to develop the questionnaires that can measure objectively menstrual quantity and determine quantity index. Method : First, we made questionnaires to measure menstrual quantity by six question. Then we investigated 1309 women's questionnaires who has the menses. Conclusion : 1. the questionnaires that can measure objectively menstrual quantity and determine quantity index was high a correlation coefficient therefore those were used Method of Menstrual Quantity(here after MMQ) calculation. Those were added and averaged. 2. We examined correlation of calculated MMQ and women's questionnaires who has the menses therefore we got 0.30~0.47 correlation. 3. MMQ 1~3(hypomenorrhea) was 39 persons 3.19%, MMQ 4~6(normal menorrhea) was 1050 persons 85.85% and MMQ 7~10(hypermenorrhea) was 134 persons 10.96%. MMQ 4 tended to be little and MMQ 6 tended to be much. 4. MMQ confidence was high as 82% comparatively so we thought MMQ was appropriate as the measured method of menstrual quantity.
Journal of the Korea Institute of Information and Communication Engineering
/
v.21
no.12
/
pp.2291-2297
/
2017
This paper describe to extract speech measure algorithm for evaluating a speech database, and presents generating method of a speech quality measure using DNN(Deep Neural Network). In our previous study, to produce an effective speech quality measure, we propose a combination of various speech measures which are highly correlated with WER(Word Error Rate). The new combination of various types of speech quality measures in this study is more effective to predict the speech recognition performance compared to each speech measure alone. In this paper, we describe the method of extracting measure using DNN, and we change one of the combined measure from GMM(Gaussican Mixture Model) score used in the previous study to DNN score. The combination with DNN score shows a higher correlation with WER compared to the combination with GMM score.
Correlation is a technique used to measure the strength or the degree of closeness of the linear association between two quantitative variables. Common misuses of this technique are highlighted. Linear regression is a technique used to identify a relationship between two continuous variables in mathematical equations, which could be used for comparison or estimation purposes. Specifically, regression analysis can provide answers for questions such as how much does one variable change for a given change in the other, how accurately can the value of one variable be predicted from the knowledge of the other. Regression does not give any indication of how good the association is while correlation provides a measure of how well a least-squares regression line fits the given set of data. The better the correlation, the closer the data points are to the regression line. In this tutorial article, the process of obtaining a linear regression relationship for a given set of bivariate data was described. The least square method to obtain the line which minimizes the total error between the data points and the regression line was employed and illustrated. The coefficient of determination, the ratio of the explained variation of the values of the independent variable to total variation, was described. Finally, the process of calculating confidence and prediction interval was reviewed and demonstrated.
Choi, In Young;Kang, Young June;Hong, Kyung Min;Ko, Kwang Su;Kim, Sung Jong
Journal of the Korean Society for Precision Engineering
/
v.31
no.10
/
pp.889-895
/
2014
Machine parts and structures of a change in the displacement and strain can be evaluated safety is one of the important factors. Typically the strain gauge has been employed to measure the displacement and strain. However, this contact-type measurement method has disadvantages that are not measured under condition of specific object shape, surface roughness and temperature. In particularly, 3 point bending and 4 point bending test not use strain gauge. So its test used cross head displacement and deflect meter. Digital Image Correlation measurement methods have many advantages. It is non contact-type measurement method to measure the object displacements and strain. In addition, it is possible to measure the Map of full field displacements and strain. In this paper, measured the 3 point bending deflection using the Digital Image Correlation methods. In order to secure the reliability, Digital Image Correlation method and universal test machine were compared.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.