• Title/Summary/Keyword: correlation measure

Search Result 2,644, Processing Time 0.032 seconds

Two Noise Parameter Measurement Methods Using Spectrum Analyzer and Comparison (스펙트럼 분석기를 이용한 2가지 잡음 파라미터 측정방법과 비교)

  • Lee, Dong-Hyun;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.12
    • /
    • pp.1072-1082
    • /
    • 2015
  • In this paper, we propose two noise parameter measurement methods using spectrum analyzer. First method, we measure a noise correlation matrix using the 6-port network, and we calculate noise parameters using measured a noise correlation matrix. Second method, we directly measure noise figures of the DUT for source impedance changes, and then noise parameters are extracted from the measured noise figures. In order to measure a noise figure, we present a method of measuring a noise figure of the DUT that have arbitrary source impedances using spectrum analyzer and a method of eliminating a noise effect of a impedance tuner. Finally, the noise parameters of a passive and active DUT using proposed two methods are compared. The comparison shows that the two results obtained from for the two methods give almost identical noise parameters. The noise parameters measured by 6-port network accurately predict measured noise figures of the DUT for source impedance changes, and noise parameters measured by 6-port network is verified from the comparison.

Diagnostic values of abdominal muscles thickness and sterno-costal angle for young adults with rounded shoulders

  • Lee, Chan-hee;Hwang, Sujin
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.1
    • /
    • pp.49-54
    • /
    • 2020
  • Objective: The purposes of this study was to evaluate the diagnostic values of abdominal muscles thickness and sterno-costal angle as the quantitative diagnostic indicators for young adults with rounded shoulders. Design: A observational, cross-sectional study. Methods: This study included thirty-three male participants in order to examine the relationship among thoracic kyphosis, sternocostal angle, and abdominal muscle thickness. We used ultrasound imaging to measure the muscle thickness, two gravity-dependent inclinometers to measure the kyphosis angle, and Image J to measure the sterno-costal angle. Results: There was a significant positive correlation between the amount of thoracic kyphosis angle and muscle thickness of the external oblique (EO) on the right side (r=0.931), and on the left side (r=0.432), and the transverse abdominis (TrA) (r=0.649). There was also a significant negative correlation between the thoracic kyphosis angle and the sterno-costal angle at the right side (r=-0.942) and at the left side (r=-0.860). There was a significant positive relationship with muscle thickness of the EO and TrA on the right side with the thoracic kyphosis angle, and was significant negative relationship with the sterno-costal angle on both sides. Conclusions: The results of the study suggest that the thoracic kyphosis angle is related to muscle thickness of the EO and TrA on the dominant side and the sterno-costal angle. We also suggest that future studies are needed to determine how strengthening the abdominal muscles may contribute to preventing excessive thoracic kyphosis in young adults.

Reliability and Validity of Measurement Using Smart Phone-Based Goniometer on Pelvic Tilting Angle in Standing and Sitting Position

  • Ha, Sung-Min;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.1
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose: The purpose of this study was to assess the intra-rater and inter-rater reliability and validity of pelvic tilting angle measurements using a smart phone-based inclinometer (Clino) compared to a palpation meter (PALM) in the standing and sitting position. This study used an interchangeable method with Clino to measure the pelvic tilting angle in the standing and sitting positions. Methods: Twenty healthy subjects were recruited. Measurements of the pelvic tilting angle in the standing and sitting positions were obtained by two examiners using the Clino and PALM. A resting session was conducted 10 minutes later to assess the intra and inter rater reliability. To assess validity of the measurement using Clino, a PALM was used as the gold standard. The intra-class correlation coefficient (ICC) was used to determine the intra and inter rater reliability of Clino and a PALM. To assess the validity, the Pearson correlation coefficients were used for two measurement techniques to measure the pelvic tilting angle in the standing and sitting positions. The statistical significance was set to ${\alpha}=0.05$. Results: Measurements of the pelvic tilt had high inter-rater reliability in the standing (ICC=0.82) and sitting (ICC=0.88) positions using Clino and intra-rater reliability in the standing (ICC=0.87) and sitting (ICC=0.91) positions using Clino. Measurements of the pelvic tilt had high validity by a comparison of PALM and Clino in the standing (r=0.83) and sitting (r=0.89) positions (p<0.05). Conclusion: The use of Clino can be recommended as a tool to replace the PALM and measure the pelvic tilt angle in the standing and sitting positions while maintaining the clinical reliability and validity.

Measuring Level of Difficulty of Fingerprint Database based on Sample Quality (영상 품질 기반의 지문 데이터베이스의 난이도 정량화)

  • Ryu, Ji-Eun;Jang, Ji-Hyeon;Kim, Hak-Il
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.18 no.5
    • /
    • pp.59-69
    • /
    • 2008
  • The purpose of this paper is to measure the level of difficulty of fingerprint database based on sample quality. This paper proposes distribution of a sample quality analyzer and a difference of sample quality analyzer to measure the level of difficulty. Experimental results demonstrate that there are stronger correlation between matching performance and level of difficulty based on difference of sample quality than other measure. Especially, level of difficulty based on OQ Block of MPQ co-occurrence matrix shows highest correlation with matching performance, and moreover it can predict the matching performance of unknown databases.

The Relationship between Neurocognitive Functioning and Emotional Recognition in Chronic Schizophrenic Patients (만성 정신분열병 환자들의 인지 기능과 정서 인식 능력의 관련성)

  • Hwang, Hye-Li;Hwang, Tae-Yeon;Lee, Woo-Kyung;Han, Eun-Sun
    • Korean Journal of Biological Psychiatry
    • /
    • v.11 no.2
    • /
    • pp.155-164
    • /
    • 2004
  • Objective:The present study examined the association between basic neurocognitive functions and emotional recognition in chronic schizophrenia. Furthermore, to Investigate cognitive variable related to emotion recognition in Schizophrenia. Methods:Forty eight patients from the Yongin Psychiatric Rehabilitation Center were evaluated for neurocognitive function, and Emotional Recognition Test which has four subscales finding emotional clue, discriminating emotions, understanding emotional context and emotional capacity. Measures of neurocognitive functioning were selected based on hypothesized relationships to perception of emotion. These measures included:1) Letter Number Sequencing Test, a measure of working memory;2) Word Fluency and Block Design, a measure of executive function;3) Hopkins Verbal Learning Test-Korean version, a measure of verbal memory;4) Digit Span, a measure of immediate memory;5) Span of Apprehension Task, a measure of early visual processing, visual scanning;6) Continuous Performance Test, a measure of sustained attention functioning. Correlation analyses between specific neurocognitive measures and emotional recognition test were made. To examine the degree to which neurocognitive performance predicting emotional recognition, hierarchical regression analyses were also made. Results:Working memory, and verbal memory were closely related with emotional discrimination. Working memory, Span of Apprehension and Digit Span were closely related with contextual recognition. Among cognitive measures, Span of Apprehension, Working memory, Digit Span were most important variables in predicting emotional capacity. Conclusion:These results are relevant considering that emotional information processing depends, in part, on the abilities to scan the context and to use immediate working memory. These results indicated that mul- tifaceted cognitive training program added with Emotional Recognition Task(Cognitive Behavioral Rehabilitation Therapy added with Emotional Management Program) are promising.

  • PDF

An Objective Speech Quality Measure using Masking Effect under Digital Mobile Telephone Network Environment (디지털 이동통신망 환경 하에서 마스킹 효과를 이용한 객관적 음질 평가 척도)

  • 김광수;김민정;석수영;정호열;정현일
    • Journal of Korea Multimedia Society
    • /
    • v.5 no.4
    • /
    • pp.405-414
    • /
    • 2002
  • In this paper, we propose a new objective speech quality measure using noise masking threshold for speech quality assessment of mobile telephone network environments, and verify the effectiveness of the proposed method through the experiments. For such a purpose, well known objective speech quality measures such as BSD and PSQM are first evaluated for digital mobile telephone network environments. However, these conventional methods does not have good performance under mobile networks environments compared to literary results. To be mote effective objective speech quality measure under mobile telephone environments, the proposed method employs human psychoacoustic masking effect. The DMOS, instead of MOS, is used as a subjective speech quality measure for performance evaluation. The performance comparison are carried out with speech data collected from digital mobile telephone environments. As results, the proposed measure have and average 4% higher performance, in terms of correlation, than existing objective speech quality measures such as BSD and PSQM.

  • PDF

A Study for Testing Validity of Korean Pain Measurement Tool (국어통증척도의 타당도 연구)

  • 김주희
    • Journal of Korean Academy of Nursing
    • /
    • v.16 no.1
    • /
    • pp.81-88
    • /
    • 1986
  • The main purpose of this study was to clarify the validity with patient's general background of Korean Pain Measurement tool. The subjects of this study were 195 patient from the 8 Med-Surgical wards in H. University Hospital in Seoul. The study was conducted over a 40 day period from Oct. 5, 1985 to Nov. 15, 1985. All patients had pain. Korean Pain Measurement tool and simple discriptive pain scale as Graphic Rating Scale were used to measure the pain, The Pearson Correlation Coefficient test was exercised to measure the correlation between the two kinds of pain tools. To clarify the Sensitivity of Korean Pain tool was used frequency with patient's response. To compare the difference in Pain levels with patient's general background, ANOVA and t-test was employed. To compare the difference in pain levels existed due to pain area of the body used mean numbers. The outcome of the study was as follows : 1. A positive correlation did exist between two pain measurement tools. (r=.2028∼.7768, p <0.002) 2. The sensitive subclass in Korean Pain Measurement tools was 7 subclass. The 7 subclass are inflammatory repeated pain, simple stimulating, traction pressure, dull pain, cavity pain, digestion related pain, suffering. related pain. 3. The existence of levels of pain in accordance with patient's general background, the department of hospital, pain area of the body and school age was supported. Age, sex, religion, marrital status, economic status, acute or chronic status was not supported. 4. The existence of higher pain levels of the body area was anus, chest, and lower pain levels of the body area was eye, ear, nose and throat. Based on the above results, it was found that sensitive subclasses of the Korean Pain Measurement tool was 7 subclass among all of 20 subclass. Thus it can be concluded that Korean Pain Mea-surement tool when partialy used and supplemented, can be an effective tool of pain measurement for the patient in Korea.

  • PDF

Study on the Development of the Displacement and Strain Distribution Measurement Algorithm to the Open Hole Tension Test by Using the Digital Image Correlation (이미지 상관법을 이용한 원공 인장 시편 변위 및 변형율 측정을 위한 알고리즘 개발에 관한 연구)

  • Choi, In Young;Kang, Young June;Hong, Kyung Min;Lee, Hak Seong;Kim, Seong Jong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.2
    • /
    • pp.121-128
    • /
    • 2016
  • The mechanical jointing method is very important in the machine parts and structure. They are used by the bolts and rivet because it is very convenient to replace the parts and the structure. However, the mechanical jointing methods using the bolt and rivet needed the open hole. The machine parts life cycle is reduced because this open hole created the stress concentration. Therefore, the measurement methods are needed to evaluate phenomenon of the stress concentration. This paper discusses the development of the measurement algorithm using the digital image correlation methods to measure the strain distribution of the open hole. To implement the measurement algorithm using the DIC, the LabVIEW 2010 programming tool was used. To measure the strain distribution of the open hole, the tensile specimens having an open hole are made by using the aluminum 6061-T6. To secure the reliability of measurement result using the DIC, the DIC measurement results and FEM analysis results were compared.

Development and Evaluation of skin Hydration Measure System using the Suscepance Method (Susceptance를 이용한 피부수화도 측정 장비의 개발 및 평가)

  • Kim, Hong-Sig;Jang, Woo-Young;Shin, Kun-Soo;Cho, Baek-Hwan;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.6
    • /
    • pp.493-501
    • /
    • 2008
  • In this paper, a novel system is proposed to measure skin hydration using the susceptance method. This system largely consists of a low-voltage(${\pm}2.6$ V) driven circuit and minimized electrodes of size($5{\times}5mm^2$). To evaluate the accuracy of the novel system in measuring skin hydration, skin hydration values from 105 subjects are measured by the proposed system. The measurements are then compared to those obtained by the golden reference device based on the capacitance method in terms of Intraclass Correlation Coefficient(ICC) and correlation coefficient. All measurements are performed on 7 sites, which are forehead, Crow's foot, cheek, chin, volar forearm, dorsal forearm, and back of the hand, in a room where the temperature and humidity are maintained at an uniform level of $22{\pm}2^{\circ}C$ and $50{\pm}5%$, respectively. ICC values are above 0.9(p=0.001), signifying that the skin hydration values measured by the two methods show a good level of reliability. Correlation coefficient between the two methods is also 0.562(p=0.001). Based on these results, it is expected that the proposed system may be applicable in a variety of clinical or cosmetic areas.

Efficient Hardware Architecture for Fast Image Similarity Calculation (고속 영상 유사도 분석을 위한 효율적 하드웨어 구조)

  • Kwon, Soon;Lee, Chung-Hee;Lee, Jong-Hun;Moon, Byung-In;Lee, Yong-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.4
    • /
    • pp.6-13
    • /
    • 2011
  • Due to its robustness to illumination change, normalized cross-correlation based similarity measurement is widely used in many machine vision applications. However, its inefficient computation structure is not adequate for real-time embedded vision system. In this paper, we present an efficient hardware architecture based on a normalized cross correlation (NCC) for fast image similarity measure. The proposed architecture simplifies window-sum process of the NCC using the integral-image. Relieving the overhead to constructing integral image, we make it possible to process integral image construction at the same time that pixel sequences are inputted. Also the proposed segmented integral image method can reduce the buffer size for storing integral image data.