• Title/Summary/Keyword: corrected of axis

Search Result 82, Processing Time 0.02 seconds

Model Parameter Correction Algorithm for Predictive Current Control of SMPMSM

  • Li, Yonggui;Wang, Shuang;Ji, Hua;Shi, Jian;Huang, Surong
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1004-1011
    • /
    • 2016
  • The inaccurate model parameters in the predictive current control of surface-mounted permanent magnet synchronous motor (SMPMSM) affect the current dynamic response and steady-state error. This paper presents a model parameter correction algorithm based on the relationship between the errors of model parameters and the static errors of dq-axis current. In this correction algorithm, the errors of inductance and flux are corrected in two steps. Resistance is ignored. First, the proportional relations between inductance and d-axis static current errors are utilized to correct the error of model inductance. Second, the flux is corrected by utilizing the proportional relations between flux and q-axis static current errors under the condition that inductance is corrected. An experimental study with a 100 W SMPMSM is performed to validate the proposed algorithm.

Effect of Visual acuity for Change of Astigmatism axis in Myopic astigmatism (근시성 난시안에서 난시축 변화가 시력에 미치는 영향)

  • Choi, Jun-Gyu;Kim, Bo-Yun;Lee, Eun-Hee
    • Journal of Digital Convergence
    • /
    • v.13 no.12
    • /
    • pp.285-290
    • /
    • 2015
  • The purpose of this study is to compare the status of eyesight according to the change of astigmatism axis in myopic astigmatism and to minimize errors in making astigmatic glasses based on accurate optometry and prescription. The subjects were 93 males and females(186 eyes) who have myopic astigmatism without any ocular disease or systemic disease. We performed comparative analysis on the status of visual acuity according to the change of astigmatism axis to 5, 10 and 15 degree in corrected eyesight 1.0. The direct astigmatism was the most common astigmatism type among the 186 eyes. After all subjects were perfectly corrected into 1.0, the change of astigmatism axis affected eyesight; The results suggested that the more change was made in astigmatism axis, the worse their eyesight would become. The main astigmatism type was changed from direct astigmatism to inverse astigmatism as age increased. The change of the astigmatism axis resulted in failing of corrected eyesight. Therefore, the convergence of examination and correction for astigmatism strength and axis is necessary when conducting refraction inspection for astigmatism.

Optical System Design for a Head-up Display Using Aberration Analysis of an Off-axis Two-mirror System

  • Kim, Byung-Hyun;Park, Sung-Chan
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.481-487
    • /
    • 2016
  • This study presents a new optical system for a combiner-type head-up display (HUD) with a cylindrical lens as an asymmetrical aberration corrector, instead of a freeform mirror. In the initial design process based on off-axial aberration analysis, we obtain an off-axis two-mirror system corrected for linear astigmatism and spherical aberration by adding a conic secondary mirror to an off-axis paraboloidal mirror. Thus, since the starting optical system for an HUD is corrected for dominant aberrations, it enables us to balance the residual asymmetrical aberrations with a simple optical surface such as a cylinder, not a complex freeform surface. From this design process, an optical system for an HUD having good performance is finally obtained. The size of the virtual image is 10 inches at 2 meters away from a combiner, and the area of the eye box is 130×50 mm2.

A Study on the Relationship Between the Off-Axis Cylinder and Corrected Vision of Astigmatism (난시안의 교정축 이탈과 교정시력과의 관계 연구)

  • Kim, Jung Hee;Kang, Sue Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.83-87
    • /
    • 2007
  • This study was classified and compared astigmatism's refractional abnormal degrees with visual acuity state of full correction which turned on axises of only 5 degree, 10 degree, and 15 degree. Subjects of this study were 57 college students (114 eyes) who had neither eye diseases nor binocular abnormality, were from their twenties to fifties, with myopia. It appeared that 30.8% of subjects who had astigmatism wore glasses with wrong axis of astigmatism. After accurate correction of the visual acuity and degrees of astigmatism, when we moved to corrected axises at 5 degree, 10 degree, 15 degree, failure of visual acuity with one line or more were 56.1%, 84.2%, 93.8%, respectively. When we comapre the completely-corrected visual acuity with the visual acuity with dricted axes, the bigger the width of visual acuity's weakness was the bigger the drifted angle. The change of normal visual acuity according to drifting angle of corrected axises of astigmatism, when we compared with full correction, appeared 0.94 in 5 degree, 0.87 in 10 degree, and 0.79 in 15 degree. Drift of 5 degree from fully corrected axis, corresponded to difference of visual acuity about one line, drift of 10 degree to 1.8 line difference of visual acuity, and drift of 15 degree about to 2.6 line difference. Through this study, we were sure that, in the case of drifting away from the right axis of astigmatism, it lead to visual weakness and asthenopia. Therefore we darely advise that optometrists should make mistake of axis least by confirming accucacy of corrected axis after despensing of spectacles of astigmatism.

  • PDF

Development of Online Realtime Positioning Error Compensation System for CNC Machine Tools (CNC 공작기계용 온라인 실시간 위치오차 보정시스템의 개발)

  • Chung, Chae-Il;Kim, Jong-Won;Nam, Weon-Woo;Lee, Sang-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.10
    • /
    • pp.45-52
    • /
    • 1999
  • The online realtime positioning error compensation system 'SKY-PACS' is developed to correct geometric errors, thermal errors and tool deflection errors induced by cutting forces on the vertical machining center. 'SKY-PACS' communicates position commands and position compensation signals with the CNC controller at 100Hz, which is CNC control frequency. So the compensation procedure can be applied during axis movement. Using 'SKY-PACS', Maximum 1 axis positioning accuracy was corrected from 5{\mu}m$ to 2{\mu}m$and the squareness error of X-Y table was corrected from 51{\mu}m$/m to below 4{\mu}m$/m. The error compensation under the cutting condition is carried out by ISO10791-7. And the measurement of test-pieces shows that the roundness is corrected rom 8{\mu}m$ to below 5{\mu}m$.

  • PDF

Lens Design of the Eyepiece Combined with the Accommodation-dependent Navarro Eye at an On-axis Point

  • Choi, Ka-Ul;Song, Seok-Ho;Kim, Sang-Gee
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.55-62
    • /
    • 2010
  • We introduce a new method for lens design that combines an eyepiece with the finite model eye, to make a corrected version of the accommodation-dependent Navarro eye. The optical system that we designed, which includes a human eye, takes into account the aberration of the eye and increases the performance of the image in the retina. In the design results, for the optimized eyepiece combined with the corrected Navarro eye, visual acuity is 1.40. Compared with the existing method of eyepiece design using inverse ray tracing with the corrected Navarro eye, MTF value was recorded as 0.079 to 0.283 at 160 lp/mm and visual performance was improved.

Optical System Design and Evaluation for an Augmented Reality Head-up Display Using Aberration and Parallax Analysis

  • Kim, Kum-Ho;Park, Sung-Chan
    • Current Optics and Photonics
    • /
    • v.5 no.6
    • /
    • pp.660-671
    • /
    • 2021
  • We present a novel optical system for an augmented reality head-up display (AR HUD) with two virtual images at different conjugates by employing a confocal off-axis two-mirror and introducing the horopter circle. For a far virtual image with large asymmetrical aberrations, we initially obtain an off-axis two-mirror system corrected for these aberrations and compensated for the down angle by configuring its parameters to satisfy the confocal and Scheimpflug conditions, respectively. In addition, this system is designed to reduce the biocular parallax by matching Petzval surface into the longitudinal horopter circle in a near virtual image. This design approach enables us to easily balance the residual aberrations and biocular parallax when configuring the optical system with two different conjugates, which results in an AR HUD available for near and far virtual images together.

Dosimetric Characteristics of Dual Photon Energy Using Independent Collimator Jaws (고에너지 선형가속기의 Independent Collimator를 이용한 비대칭 방사선 조사시 방사선량 결정에 미치는 요인에 관한 연구)

  • Kim Jeung-kee;Choi Young-Min;Lee Hyung-Sik;Hur Won-Joo
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.237-244
    • /
    • 1996
  • Purpose : The accurate dosimetry of independent collimator equipped for 6MV and 15MV X-ray beam was investigated to search for the optimal correction factor. Materials and Methods : The field size factors, beam quality and dose distribution were measured by using 6MV, 15MV X-ray Field size factors were measured from $3{\times}3cm^2$ to $35{\times}35cm^2$ by using 0.6cc ion chamber (NE 2571) at Dmax. Beam qualities were measured at different field sizes, off-axis distances and depths. Isodose distributions at different off-axis distance using $10\times10cm^2$ field were also investigated and compared with symmetric field. Result: 1) Relative field size factors was different along lateral distance with maximum changes in $3.1\%$ for 6MV and $5\%$ for 15MV. But the field size factors of asymmetric fields were identical to the modified central-axis values in symmetric field, which corrected by off-axis ratio at Dmax. 2) The HVL and PDD was decreased by increasing off-axis distance. PDD was also decreased by increasing depth For field size more than $5{\times}cm^2$ and depth less than 15cm, PDD of asymmetric field differs from that of symmetric one ($0.5\~2\%$ for 6MV and $0.4\~1.4\%$ for 15MV). 3) The measured isodose curves demonstrate divergence effects and reduced doses adjacent to the edge close to the flattening filter center was also observed. Conclusion . When asymmetric collimator is used, calculation of MU must be corrected with off-axis and PDD with a caution of underdose in central axis.

  • PDF

An Analysis of Optical Performance of the Finite Schematic Eye According to Iris Eccentricity and Visual Axis change (시축 변화와 홍채 편심에 따른 정밀모형안의 광학적 성능 분석)

  • Kim, Bong-Hwan;Han, Sun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.151-154
    • /
    • 2010
  • Purpose: We investigated how the movement of iris and visual axis affects the finite schematic eye Methods: Using the schematic eye with the crystalline lens in the existing forms of the radial GRIN and the spherical GRIN, the iris centre was moved 0.5 mm in nasal direction and visual axis was tilted $5^{\circ}$ in same direction, with the additional degree of 2.5 down to locate the focal point in fovea. This study analyzed performance change of the optical system, designing it same as the real eye. Results: The whole aberration distribution showed a considerable difference in performance in comparison with the real eye; the biggest difference shown at the central field of optical system. The spherical aberration showed the biggest difference, and a peripheral power error and field curvature leaned toward (+) direction in aberration distribution. Conclusions: When designing the schematic eye with the performance similar with that of the real eye by taking into consideration the iris centre and visual axis, the aberration at the center field of optical system in particular should be corrected. Spherical aberration which showed the biggest difference should be corrected in the first place. In addition, a peripheral power error and field curvature that leaned toward (+) direction should be moved toward (-) direction.

A study on the diagonal error compensation and squareness measurement of linear motor (리니어 모터의 직각도 측정과 대각선 오차 보정에 관한 연구)

  • Kim J.H.;Lee C.W.;Song J.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.287-288
    • /
    • 2006
  • This paper introduces an approach of method to compensate accuracy error of diagonal direction. The measurement of squareness error is an important parameter in performance test of two axis Linear Motor and this exerts influence on accuracy error of diagonal test. However, previous knowledge management approaches are limited in deviation measurement of optical axis or restrictive elements of diagonal measurements using laser interferometer. But this proposed method calculated diagonal accuracy error which was occurred by squareness error and compensated squareness error using orthogonal correction method of PMAC. From this result, diagonal accuracy error is significantly reduced. This experimental results show that geometric error of squareness error is easily corrected by dynamic coordinate correction.

  • PDF