• Title/Summary/Keyword: copper amount

Search Result 486, Processing Time 0.03 seconds

Role of Proline Accumulation in Response to Toxic Copper in Microcystis aeruginosa

  • Park, So-Hyun;Hong, Jung-Hee
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_4
    • /
    • pp.189-196
    • /
    • 2001
  • The blue green alga, Microcystis aeruginosa, was found to accumulate proline under the stressful concentration of cupric ions. The changes of proline level in Microcystis aeruginosa in response to copper(Cu) have been monitored and the function of the accumulated proline was studied with respect to its effect on Cu uptake. Exposure of Microcystis aeruginosa elevated concentrations of Cu led to accumulation of fee proline depending on the concentrations of the metal in the external medium. The greater the toxicity or accumulation of the metal, the higher the amount of proline in algal cells were found. When proline was exogenously supplied prior to Cu treatment, the absorption of Cu was markedly reduced. When exogenous proline was supplied after Cu treatment, it resulted in a remarkable desorption of the adsorbed Cu immediately after the addition of proline. Pretreatment of Microcystis aeruginosa with proline counteracted with metal-induced lipid peroxidation. The results of the present study showed a protective elect of proline on metal toxicity through inhibition of lipid peroxidation and suggested that the accumulation of proline may be related to the tolerance mechanism for dealing with Cu stress.

  • PDF

Fabrication of $Bi_{2}Sr_{2}CaCu_{2}O_{8}$ Superconducting Films by the LiReac-PreCu Method (급속반응공정에 의한 동 테이프 $Bi_{2}Sr_{2}CaCu_{2}O_{8}$)

  • 성현태;한상철;한영희;이준성;최희락
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.1
    • /
    • pp.7-14
    • /
    • 1999
  • Wekk oriented $Bi_{2} Sr_{2} CaCu_{2} O_{8}$ suppercondcting thick films were fabricared on copper tape by LiReac-PreCu (liquid reaction between a Cu-free precousor and Cu tape) method. Cu-free precursor power which is composed of $Bi_{2}Sr_{2}Ca_{5}$ was printed on a copper tape by screen printing and was heat-treated. The speciment were partially in a molten state at the heat treatment temperature (85$0^{\circ}C$~87$0^{\circ}C$). The heat heat treatments for the reaction were performed in air or low oxygen pressure in several stages. XRD analyses of the resulting Bi2Sr2CaCu2O8 superconducting tapes show that the $Bi_{2} Sr_{2} CaCu_{2} O_{8}$ phase is dominant and a small amount of $Bi_{2} Sr_{2} Cu_{2} O_{6}$ phase is detected. Both phases are aligned in the c-axis direction.

  • PDF

Preparation of Fe(III)-Coated Starfish and Evaluation of the Removal Capacity of Copper (3가철 코팅 불가사리 흡착제 제조 및 구리 제거 특성 평가)

  • Yang, Jae-Kyu;Yu, Mok-Ryun;Lee, Seung-Mok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.172-176
    • /
    • 2006
  • Fe(III)-Coated Star Fish (ICSF) was prepared by reaction of calcined Star Fish (SF) with Fe(III) solution at an elevated temperature. To investigate the stability of ICSF at acidic condition, dissolution of Fe was studied at pH 2 as a function of time. Extracted iron was negligible over the entire reaction time. This stability test suggests the applicability of ICSF in the treatment of wastewater even at low pH. Adsorption capacity of Cu(II) onto SF and ICSF was investigated in a batch and a column test. In the pH-edge adsorption, adsorption of copper onto SF and ICSF was quite similar over the entire pH range due to the presence of an important amount of Fe in SF itself. From the adsorption isotherm obtained with variation of the concentration of Cu(II), ICSF showed 1.6 times greater adsorption capacity than SF. Also, ICSF showed a greater removal capacity of Cu(II) in the column test.

Study on the Catalytic Properties of Copper Oxide Nanoparticles Synthesized by Levitational Gas Condensation (LGC) Method (부양가스증발응축법에 의해 제조된 구리산화물 나노분말의 촉매 특성 연구)

  • Uhm, Y.-R.;Kim, W.-W.;Oh, J.-S.;Rhee, C.-K.
    • Journal of Powder Materials
    • /
    • v.12 no.1
    • /
    • pp.64-69
    • /
    • 2005
  • The copper oxide nano powders were synthesized by levitational gas condensation(LGC) method, and their high heterogeneous catalytic effects of oxidation of 2,3,5-trimethyl-1,4- hydroquinone (TMHQ) and catalase activity were studied. The observation of transmission electron microscopy (TEM) shows that most of these nano powders are uniform in size, with the average particle size of 35 nm. The nano powder consists of mainly $Cu_2O$, but it is aged to CuO phase. The catalytic effect which was clarified by oxidation of TMHQ and catalase depends on the amount of cuprite phase and the particle size.

Development of a New Copper(II) Ion-selective Poly(vinyl chloride) Membrane Electrode Based on 2-Mercaptobenzoxazole

  • Akhond, Morteza;Ghaedi, Mehrorang;Tashkhourian, Javad
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.882-886
    • /
    • 2005
  • Copper(II) ion-selective PVC membrane electrode based on 2-mercaptobenzoxazole as a new ionophore and o-nitrophenyl octyl ether (o-NPOE) as plasticizer is proposed. This electrode revealed good selectivity for $Cu^{2+}$ over a wide variety of other metal ions. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, and concentration of internal solution on the potential response of $Cu^{2+}$ sensor were investigated. The electrode exhibits good response for $Cu^{2+}$ in a wide linear range of 5.0 ${\times}$ 10−.6-1.6 ${\times}$ $10^{-2}$ mol/L with a slope of 29.2 ${\pm}$ 2.0 mV/decade. The response time of the sensor is less than 10 s, and the detection limit is 2.0 ${\times}$ $10^{-6}$ mol/L. The electrode response was stable in pH range of 4-6. The lifetime of the electrode was about 2 months. The electrode revealed comparatively good selectivities with respect to many alkali, alkaline earth, and transition metal ions.

Effect of Chilgitang Extract for Herb-Acupuncture on ROS, RNS, Lipid Peroxidation and LDL oxidation (칠기탕(七氣湯) 약침액(藥鍼液)이 활성산소종, 활성질소종, 지질과산화 및 LDL의 산화에 미치는 영향)

  • Shin, Jung-Soo;Moon, Jin-Young
    • Korean Journal of Acupuncture
    • /
    • v.25 no.4
    • /
    • pp.89-104
    • /
    • 2008
  • Objectives : This study was undertaken to determine the in vitro antioxidant activity of the extract of Chilgitang herb-acupuncture solution (CHAS). Methods : The radical scavenging capacity was tested by 2,2-diphenyl-1-picryl-hydrazyl (DPPH), hypoxanthine-xanthine oxidase system, DCFH-DA assay, nitric oxide and peroxynitrite generating system. In addition, antioxidant activity on copper and AAPH mediated human low-density lipoprotein (LDL) oxidation was measured by using TBARS assay and relative electrophoretic mobility assay. The amount of total phenolic compounds was assayed by the Folin-Ciocalteu method. Results : CHAS revealed a potent scavenging activity on DPPH radical(82%), superoxide anions(73%), hydroxyl radical(63%), nitric oxide (99%) and peroxynitrite (99%). Moreover, CHAS showed a strong inhibitory effect (59%) on $FeCl_2$-ascorbic acid induced lipid peroxidation of rat liver homogenate. CHAS also markedly inhibited copper(81%) and AAPH(56%)-mediated LDL oxidation, and effectively suppressed the electrophoretic mobility during exposure of human LDL to copper ions. CHAS (82 mg/g) contained higher concentration of total phenolic compounds than that of water extract (45 mg/g) obtained from Chilgitang. Conclusions : These results indicate that CHAS may protect against ROS- or RNS involved diseases, including cardiovascular diseases.

  • PDF

Study on tin immersion plating on printed circuit boads (무전해 주석도금시의 문제점과 그 대책에 대한 연구)

  • 김동필;염희택
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.3-3
    • /
    • 2001
  • Two companies plating baths were selected for plating on phenol and epoxy resin boards as well as on flexible p polyimide boards. After plating, deposited i&IIk&.ness al1d physical properties, as well as solder wettabilities by aging with $150^{\circ}C$ heating and 100% humidity were compared. After plating and aged with two different tin baths, deposited thickness and physical properties were not so great differences, but solder wettabilities were superior used polymer catalyst than the other. Furthermore depend upon the compactness and fineness of metallic sturctures of the base copper, the amounts of the plated copper were big differel1lces. These differences seems to be inherited from the kind and amount of additives. as well as current densities, which are influences upon structures of Copper layers. Generally the tin thickness are hetween 0.5 to $1.0\mu\textrm{m}$ and thicker the solder wettabilities are the better, and also me compact structures of deposits showed gooo soidierabiiities. In this study, with our own deveiotaedl plating equipment could get more than $0.5\mu\textrm{m}$ of till thickness and piating speed was $0.1\mu\textrm{m}$ per minutes.

  • PDF

PHASE TRANSITIONS AND ELECTROCHEMICAL CORROSION BEHAVIORS OF Ti50Ni50-xCux SHAPE MEMORY ALLOYS FOR METALLIC BIOMATERIALS

  • KWANGMIN LEE;SANGHYUN RHO
    • Archives of Metallurgy and Materials
    • /
    • v.65 no.4
    • /
    • pp.1303-1306
    • /
    • 2020
  • TiNi alloys have excellent shape memory properties and corrosion resistance as well as high biocompatibility. This study investigated the effects of copper addition on the phase transitions and electrochemical corrosion behaviors of Ti50Ni50-xCux alloys. TiNi, Ti50Ni47Cu3, Ti50Ni44Cu6, and Ti50Ni41Cu9 alloys were prepared using vacuum arc remelting followed by 4 h homogenization at 950℃. Differential scanning calorimetry and X-ray diffraction analyses were conducted. The corrosion behaviors of the alloys were evaluated using potentiodynamic polarization test in Hank's balanced salt solution at a temperature of 36.5 ± 1℃. The TiNi alloy showed phase transitions from the cubic B2 phase to the monoclinic B19' phase when the alloy was thermally cycled. The addition of copper to the TiNi alloy played a major role in stabilizing the orthorhombic B19 phases during the phase transitions of Ti50Ni50-xCux alloys. The shifts in the corrosion potential toward the positive zone and the low corrosion current density were affected by the amount of Cu added. The corrosion resistance of the TiNi alloy increased with increasing copper content.

Tribology of Cu-based Electrical Contacts in Slipring-Brush Assembly (구리 기지 복합재료의 전기적 접촉에 의한 마찰 마모 특성에 관한 연구)

  • Park, Hyung-Kyu;Jang, Ho
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.06a
    • /
    • pp.187-193
    • /
    • 2000
  • Friction characteristics and electrical resistance of sliding contacts in slipring-brush assembly were investigated. Four brush materials containing relative amounts of copper and graphite were studied. The result showed that a copper-graphite brush at a particular graphite content exhibited the most stable frictional and electrical behaviour suggesting an optimum amount of solid lubricant in metal-graphite brush system. Microscopic observation and the surface analysis showed good agreement with this phenomena.

  • PDF

Experimental Study of Emissivity with the Variation of Temperature and Shape Factor Using the Radiation Apparatus (복사 장치를 이용한 온도와 형상계수의 변화에 따른 방사율에 관한 실험적 연구)

  • Kim, Chung-Rae;Jeong, Byung-Cheol;Kang, Hyung-Suk
    • Journal of Industrial Technology
    • /
    • v.25 no.B
    • /
    • pp.135-140
    • /
    • 2005
  • Voltage of radiometer is measured experimentally using the radiation apparatus in each case of iron- and copper-plates as specimen heating device. The length between radiometer and conical shield and the temperature of specimen heating device are considered as variables. The length between radiometer and conical shield controls the amount of radiation from the specimen heating device. Emissivity for both iron-and copper-plates are calculated by using Stefan-Boltzmann equation. One of results shows that emissivity for both materials increases as the length between radiometer and conical shield increases.

  • PDF