• Title/Summary/Keyword: cop

Search Result 1,228, Processing Time 0.035 seconds

Changes of Center of Pressure and Cadence Analysis According to the Carrying Type and Weight of a Bag in College Students (일부 대학생들의 가방 휴대 방법과 무게에 따른 압력중심점 변화와 보행률 분석)

  • Kim, Chang-Yong;Jeong, Hye-Won;Kim, Hyeong-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2012-2019
    • /
    • 2015
  • This study examined the changes in the center of pressure (COP) and cadence according to three types of bags carried and three different bag weights. The experimental period was from June 3, 2013 to January 20, 2014, and thirty eight healthy adults (mean age: $26.10{\pm}5.32$ years, age range: 22-30 years) volunteered under three conditions. In the first condition, the subjects wore a bag over one shoulder and they walked. In the second condition, they carried a bag across the shoulder and walked. With the third condition, they carried a backpack using both shoulders and walked. 3-Dimentional motion analysis system and a force plate were used to measure the kinematic parameters of gait and COP displacement during gait. Each subject walked 6 meters carrying a 3kg, 5kg and 7kg bag under all three conditions. The COP of the antero-posterior and medio-lateral, and cadence variable were significantly different according to the bag weight of 3kg, 5kg and 7kg. These findings suggest that walking while carrying a backpack using both shoulders is more effective on the changes in COP and gait of adults than the other conditions.

Evaluation of the Elderly Gait Stability Using the Center of Mass and Center of Pressure Inclination Angles (전, 후방 기울기각을 이용한 노인의 보행안정성 평가)

  • Yoon, Suk-Hoon;Kim, Tae-Sam;Lee, Jae-Hun;Ryu, Ji-Seon;Kwon, Young-Hoo
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.99-106
    • /
    • 2007
  • The gait instability in the elderly has been associated with age-related deterioration in physical strength and reducing the potential for elderly falls requires regular exercise. In 2005, National Center for Injury Prevention and Control(NCIPC) reported that most elderly falls occur during activities in daily living(ADL). To better reveal biomechanic mechanisms underlying age-related degeneration in gait stability, and to enhance the assessment of falls risk, an accurate quantification of a person's balance maintenance during locomotion is needed. Instantaneous orientation of the line connecting COP and COM can characterize whole body position with respect to the supporting foot during gait and the angle between this line and the vertical line passing through the COP known as a good assessment to detect the elderly gait instability. Therefore the purpose of this study was to investigate a 6-month walking exercise effects in reducing elderly fall risk factors by using COP-COM inclination angles. Twenty-two community-dwelling elderly participated this study. The participants performed a walking exercise(3 times/week, 1 hour/visit) for 6 months. Laboratory kinematics during walking was assessed at months 0, 3 and 6. Significant increased in gait velocity was found among periods(p=.011, $1.25{\pm}.03$, $1.32{\pm}.03$, and $1.39{\pm}.04\;m/s$ in 0-, 3-, and 6-month, respectively). Also, significant differences in anterior and posteriror inclination angles were found among the periods(p<.05; posterior inclination angles: $12.8{\pm}2.2$, $11.0{\pm}2.9$, & $10.9{\pm}1.9$; anterior inclination angles: $13.7{\pm}1.7$, $14.6{\pm}3.2$, & $1.46{\pm}.21$ in 0month, 3month, & 6month, respectively). These findings provide evidence of significant reduced fall risk factors of community-living older adults associated with a systematic walking program.

Effects of Large Display Curvature on Postural Control During Car Racing Computer Game Play (자동차 경주 컴퓨터 게임 시 대형 디스플레이 곡률이 자세 제어에 미치는 영향)

  • Yi, Jihhyeon;Park, Sungryul;Choi, Donghee;Kyung, Gyouhyung
    • Journal of the HCI Society of Korea
    • /
    • v.10 no.2
    • /
    • pp.13-19
    • /
    • 2015
  • Display technology has recently made enormous progress. In particular, display companies are competing each other to develop flexible display. Curved display, as a precursor of flexible display, are now used for smart phones and TVs. Curved monitors have been just introduced in the market, and are used for office work or entertainment. The aim of the current study was to investigate whether the curvature of a 42" multi-monitor affects postural control when it is used for entertainment purpose. The current study used two curvature levels (flat and 600mm). Ten college students [mean(SD) age = 20.9 (1.5)] with at least 20/25 visual acuity, and without color blindness and musculoskeletal disorders participated in this study. In a typical VDT environment, each participant played a car racing video game using a steering wheel and pedals for 30 minutes at each curvature level. During the video game, a pressure mat on the seat pan measured the participant's COP (Center of Pressure), and from which four measures (Mean Velocity, Median Power Frequency, Root-Mean-Square Distance, and 95% Confidence Ellipse Area) were derived. A larger AP (Anterior-Posterior) RMS distance was observed in the flat condition, indicating more forward-backward upper body movements. It can be partly due to more variability in visual distance across display, and hence longer ocular accommodation time in the case of the flat display. In addition, a different level of presence or attention between two curvature conditions can lead to such a difference. Any potential effect of such a behavioral change by display curvature on musculoskeletal disorders should be further investigated.

Performance comparison of cascade refrigerator and two-stage compression refrigerator (캐스케이드 냉동시스템과 2단 압축 1단 팽창식 냉동 시스템의 성능 비교)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.625-631
    • /
    • 2014
  • In order to obtain a low evaporation temperature ranging from $-30^{\circ}C{\sim}-50^{\circ}C$, a cascade refrigeration system and two-stage compression one-stage expansion refrigeration system is required. However, the research results of performance comparison of these refrigeration system are very scarce. This paper were compared the performance characteristics of R744-R404A cascade refrigeration system and R404A two-stage compression refrigeration system. The COP of R404A two-stage compression refrigeration system is about 36~57% greater than that of R744-R404A cascade refrigeration system in the range of evaporation temperature of $-30^{\circ}C{\sim}-50^{\circ}C$. But R404A two-stage compression refrigeration system is unstable because COP is significantly changed when evaporating temperature and compressor efficiency decreased. In particular, when compressor efficiency decreased, COP is significantly decreased. In this case, not efficient for long-term use. Whereas R744-R404A cascade refrigeration system using natural refrigerants. Therefore, it is environmentally friendly. And this system is high-efficiency refrigeration system. The reason it can be configured by selecting the suitable refrigerant at high-temperature side and low-temperature side. From the above results, select the appropriate low temperature refrigeration system by considering the environmental and performance aspects.

The Reliability and Validity of Smart Insole for Balance and Gait Analysis (균형과 보행분석을 위한 스마트 인솔의 신뢰도와 타당도 분석)

  • Lee, Byoung-Kwon;Han, Dong-Wook;Kim, Chang-Young;Kim, Gi-Young;Park, Dae-Sung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.4
    • /
    • pp.291-298
    • /
    • 2021
  • Purpose: The Pedisole is a newly developed shoe-mounted wearable assessment system for analyzing balance and gait. This study aimed to determine the reliability and validity of the parameters provided by the system for static balance and gait analysis of healthy adults. Methods: This study included 38 healthy adults (22.4±1.9 years) with no history of injury in the lower limbs. All participants were asked to perform balance and gait tasks for undertaking measurements. For analysis of balance, both the smart Pedisole and Pedoscan systems were concurrently used to analyze the path length of the center of pressure (COP) and the weight ratio of the left and right for 10 s. Gait was measured using the smart Pedisole and GaitRite walkway systems simultaneously. The participants walked at a self-selected preferred gait speed. The cadence, stance time, swing time, and step time were used to analyze gait characteristics. Using the paired t-test, the intra-class coefficient correlation (ICC) was calculated for reliability. The Spearman correlation was used to assess the validity of the measurements. In total, data for balance from 36 participants and the gait profiles of 37 participants were evaluated. Results: There were significant differences between the COP path lengths (p<.050) derived from the two systems, and a significant correlation was found for COP path length (r=.382~.523) for static balance. The ICC for COP path length and weight ratio was found to be greater than .687, indicating moderate agreement in balance parameters. The ICC of gait parameters was found to be greater than .697 except for stance time, and there was significant correlation (r=.678~.922) with the GaitRite system. Conclusion: The newly developed smart insole-type Pedisole system and the related application are useful, reliable, and valid tools for balance and gait analysis compared to the gold standard Pedoscan and the GaitRite systems in healthy individuals.