A Study on the Characteristics of Refrigeration System Installed with Precooler, and Liquid-Vapor Separator after Expansion Device (과냉각기와 팽창장치 후 액기분리기를 적용한 냉동시스템 성능특성 연구)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.40-45
    • /
    • 2011
  • The purpose of research is to understand the characteristics of refrigeration system having a liquid-vapor phase separator after expansion device and precooling heat exchanger. After expansion process of typical refrigerant of freezer, R134a, the cold vapor of the expanded refrigerant mixture is separated in the liquid-vapor separator and introduced in the precooling heat exchanger to enable the liquid refrigerant to be subcooled. The analysis results showed that the increasing rate of refrigeration capacity and COP can be 8.6% and 1.4%, each. The cause of these performance improvements is due to the difference of the slope of saturated vapor and saturated liquid lines in Mollier diagram of refrigerant.

A Study on the Performance Characteristics of Fin-type Heat Exchanger for the Automobile Air-Conditioners (자동차 공조용 핀형 열교환기의 성능특성에 관한 연구)

  • 홍경한;전상신;이승재;박찬수;권일욱;김재열;김병철;하옥남
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.100-105
    • /
    • 2004
  • Fin-tube type(Fin-type) heat exchanger has been tested in order to replace the heat exchanger of parallel flow type(P.F -type) which is now widly used in automobile air conditioning system The following conclusions are drawn by the comparison of the characteristics of the heat exchangers. Evaporator and condenser capacities and COP(Coefficience of performance) were varied as with the compressor speed, outdoor air temperature and air flow rate changed, which much influenced on the characteristics of the air conditioning system Evaporator and condenser capacities were increased with increasing compressor speed and outdoor air temperature. Evaporator and condenser pressures of Fin-type were decreased by 7% and 5% respectively compared with those of P.F-type. The COP of Fin-type was decreased with increasing outdoor air temperature and compressor speed. The COP of P.F-type was decreased by 14% compared with that of Fin-type.

Computer Simulation of an Absorption Heat Pump for Recovering Low Grade Waste Heat (저온 폐열 회수를 위한 제1종 흡수식 열펌프의 컴퓨터 시뮬레이션)

  • Karng, S.W.;Kang, B.H.;Jeong, S.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.187-197
    • /
    • 1996
  • A computer program for thermal design analysis has been developed to predict the operating characteristics and performance of an absorption heat pump to recover $30{\sim}40^{\circ}C$ of waste hot water. The effects of heat transfer area of the system components, temperature and mass flow rate of heat transfer medium, and solution circulation rate on the system performance are investigated in detail. The results obtained indicate that the COP is increased with a decrease in the temperature of driving steam and with an increase in the temperature of waste hot water while the COP is little affected by the variation of a hot water temperature. It is also found that the heating output is increased with an increase in the temperature of waste hot water and driving steam as well as with a decrease in the temperature of hot water. The simulation results are also compared with the experimental results for a periodic operation of the system and obtained a satisfactory agreement.

  • PDF

Cycle Simulation of the Air-Conditioner Using Alternatives to R22 (R22의 대체냉매를 사용한 공기조화기의 성능 시뮬레이션)

  • Chang, S.D.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.1
    • /
    • pp.47-53
    • /
    • 1994
  • Cycle simulation of the air-conditioner was carried out using a number of candidate alternatives to R22;R32/R125/R134a(30/10/60, by mass percent), R32/R125/R134a(10/70/20), R32/R134a(25/75), R32/R134a(30/70), R32/R125(60/40), R290(propane) and R134a. In this study, we considered only the basic parts of the air-conditioner such as the compressor, the evaporator, the condenser and the capillary tube, for the purpose of analysis. The performance characteristics of alternatives considered here were examined by comparing with the case using R22 at the constant volumetric flow rate condition. The results of our analysis revealed that the use of refrigerant mixtures, R32/R134a(30/70) and R32/R125/R134a(30/10/60), was appropriate for the alternatives to R22 in view of the cooling capacity and the COP. For the case of using R134a and R290, the COP was observed to increase under the same volumetric flow rate condition, but the cooling capacity was substantially decreased. Therefore the use of R134a and R290 should be accompanied with increasing considerably the size of compressor in order to maintain the same cooling capacity of R22.

  • PDF

A Study on Cooling Characteristics of Ground Source Heat Pump with Variation of Water Switching and Refrigerant Switching Methods (수절환 및 냉매절환방식에 따른 지열히트펌프의 냉방특성에 관한 연구)

  • Cha, Dong-An;Kwon, Oh-Kyung;Park, Cha-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.605-611
    • /
    • 2012
  • The objective of this study is to investigate the influence of the cooling performance for a water-to-water 10 RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The cooling capacity and refrigerant mass flow rate of the heat pump increased with increasing ground heat source temperature. But COP of the heat pump decreased with increasing ground heat source temperature. As a result, the water switching method with counter flow, compared to a refrigerant switching method, improves the cooling capacity and COP by approximately 6~9% in average, respectively.

Heating Performance of a Ground Source Multi-Heat Pump for a Greenhouse (지열원 멀티 열펌프 시스템의 시설원예 적용 난방성능 특성 실증 연구)

  • Kang, Shin-Hyung;Choi, Jong-Min;Moon, Je-Myung;Kwon, Hyung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.337-344
    • /
    • 2010
  • Good plant-growth conditions can be achieved by means of using greenhouses. One of the main issues in greenhouse cultivation is energy savings through the development of high efficient heating and cooling system. GSHPs are one of the recommended systems to cope with this pending need. The aim of this study is to investigate the heating performance of ground source multi-heat pump system installed in a greenhouse under part load conditions. Daily average heating COP of the heat pump unit was very high by at least 7.4, because of relatively large condenser, evaporator, and mass flow rate through ground loop heat exchanger. However, the system COP, overall heating coefficient of the performance of the system with heat pump unit and GLHX, decreased drastically due to relatively large power consumption of circulating pump under part load condition. It is suggested that the technology to enhance the performance of the ground source multi-heat pump system for a greenhouse under part load conditions should be developed.

Heating Performance Analysis of Building Integrated Geothermal System With Radiant Floor Heating (복사패널이 적용된 건물일체형 지열원 시스템의 난방성능 분석)

  • Jin, Shangzhen;Lee, Jin-Uk;Kim, Taeyeon;Leigh, Seung-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.25-30
    • /
    • 2012
  • Ground source heat pumps(GSHPs) are among the most efficient and comfortable heating and cooling technologies currently available, because they use the earth's natural heat to provide heating, cooling, and often, water heating. And Building Integrated Geothermal System(BIGS) is one of GSHPs which install ground heat exchanger(GHE) in energy pile without borehole to save the investment cost. Therefore, the experiment is to evaluate the heating performance of BIGS in Korea. The experimental results indicate that the average heat pump COP and overall system's COP values are approximately 4.4 and 3.0 in one week. This study shows that the BIGS could be used for heating in Korea.

Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System Using H2O/LiBr+HO(CH2)3OH (H2O/LiBr+HO(CH2)3OH계 공냉형 이중효용 흡수식 냉방시스템의 사이클 해석)

  • Kwon, Oh-Kyung;Moon, Choon-Geun;Yoon, Jung-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.272-280
    • /
    • 1999
  • A cycle analysis was achieved to predict the characteristics by comprehensive modeling and simulation of an air-cooled, double-effect absorption system using a new $H_2O/LiBr+HO(CH_2)_3OH$ solution. The simulation results showed that the new working fluid may provide the crystallization limit 8% higher than the conventional $H_2O/LiBr$ solution. With a crystallization margin of 3wt%(weight%), the optimal solution distribution ratio was found in the range of 36 to 40%. Variation of cooling air Inlet temperature has a sensitive effect on the cooling COP and corrosion problem. The simulation of heat exchangers with UA value revealed that the absorber and the evaporator are relatively important for an air-cooled system compared with the condenser and the low temperature generator. The effect of cooling air flow rate, circulation weak solution flow rate and chilled water inlet temperature were also examined. The new working fluid may provide the COP approximately 5% higher than the conventional $H_2O/LiBr$ solution.

Effects of Lumbar Stabilization on the Trunk and Lower Limb Muscle Activity and Velocity of the Center of Pressure During Single Leg Standing

  • Cynn, Heon-Seock
    • Physical Therapy Korea
    • /
    • v.17 no.4
    • /
    • pp.1-7
    • /
    • 2010
  • The aim of this study was to investigate the effects of lumbar stabilization on both trunk and lower limb muscle activity and center of pressure (COP) in single leg standing. Surface electromyography (EMG) was used to collect muscle activity data, the mean velocity of COP was measured using a force plate, and a pressure biofeedback unit was used for lumbar stabilization training. The findings of this study are summarized as follows: 1) The EMG activity of the erector spinae decreased significantly and the activity of the rectus abdominis, internal oblique, external oblique, gluteus maximus, and gluteus medius increased significantly with lumbar stabilization single leg standing. 2) No differences in activity in the tibialis anterior, medial gastrocnemius, rectus femoris, and medial hamstrings were found with single leg standing. 3) The mean velocity of COP in the antero-posterior and medio-lateral directions in the lumbar stabilization single leg standing decreased significantly compared with the preferred single leg standing. The findings of this study therefore indicate that lumbar stabilization can facilitate the co-activation of deep stabilization and global muscles that improve postural control capability during single leg standing.

Experimental study on the performance of heat pump system using $CO_2$ (이산화탄소용 열펌프시스템의 성능특성에 관한 실험적 연구)

  • Jang, Seong-Il;Jeon, Min-Ju;Yu, Tae-Guen;Son, Chang-Hyo;Oh, Hoo-Kyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.55-56
    • /
    • 2006
  • 냉매 충전량과 이차유체의 입구조건은 $CO_2$용 열펌프시스템의 성능실험에서 중요한 제어변수이다. 따라서, 열펌프사이클의 적용과 난방성능 향상을 위해 제어변수의 특성을 조사하는 것이 필요하다. 본 논문에서, $CO_2$용 열펌프 사이클의 성능 실험은 여러 가지 냉매 충전량에서 이차유체 입구조건에 변화를 주어 수행 되었다. 실험결과, 난방COP는 냉매 충전량이 증가함에 따라 1158g의 냉매 충전량에서 최대가 되었다가 감소하는 경향이 나타나며, 이는 COP가 최대가 되는 냉매충전량이 존재함을 나타낸다. 또한, 난방성능은 가스쿨러내 이차유체의 질량유량의 증가에 따라 증가하였다. 가스냉각기내 2차유체의 입구은도가 $10^{\circ}C$에서 $40^{\circ}C$로 증가하면, 난방용량, 압축일량, 토출압력은 각각 -8.57%, -35.89%, 32.78%로 변화했으며, 증발기 2차유체의 입구 온도가 감소하였을 때 난방COP는 감소하는 경향을 보였다.

  • PDF