• Title/Summary/Keyword: cop

Search Result 1,225, Processing Time 0.02 seconds

Experimental Study on the Performance of Refrigeration Cycle for various RPM of Inverter Scroll Compressor (전동 스크롤압축기의 운전rpm에 따른 냉동사이클의 성능에 대한 실험적 연구)

  • Lee, K.S.;Lee, K.A.;Lee, H.Y.;Lee, Y.S.;Kim, Jeongbae
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.42-48
    • /
    • 2014
  • An experimental study was performed estimating COP(Coefficient of Performance) of air-conditioning cycle with inverter scroll compressor. All experiments were done for various compressor speeds from 1000~4000 rpm and used the inverter controller called CANDy to change the compressor rpm. The air-conditioning cycle components in the apparatus were used as same with components of YF hybrid car. To estimate the COP, this study measured the temperature and pressure at inlets and outlets of compressor, condenser, and evaporator. And also measured the compressor input power using Powermeter. Through the experiments, the maximum error to estimate COP was shown about ${\pm}6.09%$ at 3500rpm. This study revealed that the condenser temperature and pressure were increased and the evaporator temperature and pressure were decreased with the increased compressor speed. And also, the COP was decreased with increased compressor speed. Those results can be used the basic and fundamental data to design the air-conditioning cycle with inverter scroll compressor.

Effects of Robotic Gait Training with Lower Extremity Restraint on Static Balance, Lower Extremity Function, Gait Ability in Subacute Stroke Patients

  • Kang, Yun-Su;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.3
    • /
    • pp.270-277
    • /
    • 2021
  • Objective: The purpose of this study is to compare the effect of static balance, lower extremity function, and gait ability between a lower extremity restrain robot gait training and a general robot gait training in subacute stroke subjects. Design: Two-group pretest-posttest design. Methods: A total of 12 subacute stroke patients were randomly divided into an Experimental group (n=6) and a control group (n=6). Both groups were performed for four weeks, three times a week, for 20 minutes. To compare the Static balance function, the center of pressure (COP) path-length and COP velocity were measured. The Fugl-Meyer assessment lower extremity (FMA-LE) were evaluated to compare the Lower Extremity function. 2D Dartfish Program and 10 Meter Walking Test (10 MWT) on Gait ability were evaluated to compare the gait function. Results: In the intra-group comparison, Experimental groups showed significant improvement in COP path-length, velocity, Lower Extremity Function, 10 MWT, Cadence, by comparing the parameters before and after the intervention (p<0.05). Comparison of the amount of change between groups revealed significant improvement for parameters in the COP path-length, velocity, Lower extremity function, 10 MWT by comparing the parameters before and after the intervention (p<0.01). Conclusions: The Experimental group showed enhanced efficacy for variables such as COP path-length, velocity, Lower extremity function, 10 MWT as compared to the control group.

Effects of Ankle and Hip Strategy Training on Improving the Center of Pressure Movements and Limits of Stability in Stroke Patients

  • Park, Shinjun;Park, Sunghyun;Kim, Yongyoun
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.3
    • /
    • pp.1823-1829
    • /
    • 2019
  • Background: Stroke patients have leg muscle weakness and impaired balance resulting in compensatory changes. To restore balance in these patients, functional training using postural strategy is needed. Objective: To examine the effects of ankle and hip strategy training on the center of pressure (COP) movement and limits of stability (LOS) in standing posture in stroke patients. Design: The study was an assessor-blinded and randomized-controlled clinical trial. Methods: Thirty patients were randomly assigned to an ankle strategy training group and a ankle/ hip strategy training group. Patients in the ankle strategy training group underwent ankle strategy exercise for 30 min, and those in the ankle/ hip strategy training group underwent 15 min of ankle strategy exercise and 15 min of hip strategy exercise. Both groups underwent training thrice a week for four weeks. Forward, backward, paretic side, and non-paretic side COP movements and LOS were measured using BioRescue. Results: After the intervention, except for the backward area in the ankle strategy training group, the COP movement area and the LOS were significantly improved in both the groups. In addition, these improvements were significantly higher in ankle/ hip strategy training group than that in the ankle strategy training group. Conclusions: Ankle strategy training in addition to hip strategy training improves COP movement (forward-backward, paretic side area, and non-paretic side area) and LOS in stroke patients.

SMOOTHING APPROXIMATION TO l1 EXACT PENALTY FUNCTION FOR CONSTRAINED OPTIMIZATION PROBLEMS

  • BINH, NGUYEN THANH
    • Journal of applied mathematics & informatics
    • /
    • v.33 no.3_4
    • /
    • pp.387-399
    • /
    • 2015
  • In this paper, a new smoothing approximation to the l1 exact penalty function for constrained optimization problems (COP) is presented. It is shown that an optimal solution to the smoothing penalty optimization problem is an approximate optimal solution to the original optimization problem. Based on the smoothing penalty function, an algorithm is presented to solve COP, with its convergence under some conditions proved. Numerical examples illustrate that this algorithm is efficient in solving COP.

The Performance Investigation of 1/4 Wavelength Thermoacoustic Refrigerator with Helium Refrigerant (헬륨을 냉매로 사용한 1/4파장 열음향 냉동기의 성능 평가)

  • 송규조;박종호;이성노
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.52-57
    • /
    • 2002
  • In this study, a thermoacoustic refrigerator, using a resonant standing acoustic wave. has been built. The refrigerant is helium gas. The description of thermoacoustic refrigerator was Presented. The temperature ratio (cold part temperature over hot part temperature) and the COP (Coefficient of Performance) that normalized by carnot's COP are plotted versus the thermal load applied to the cold end, for- various speaker power.

Overview of Project on COP Increase of Refrigeration Cycle using nano-fluids (나노유체를 이용한 냉동사이클 효율 향상 과제의 소개)

  • Kim, Jeongbae;Lee, Kyu Sun;Lee, Geun An
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.2
    • /
    • pp.29-32
    • /
    • 2011
  • In this paper, we will introduce the overview of new project dealing how to increase of refrigeration cycle COP using nano-fluids, CuO, TiO2, Al2O3, that are used on similar previous studies. Recently many studies were performed to show the effect of nano-fluids at refrigeration cycle. But, the reason was not cleared yet. In general, the flow phenomena at the evaporator were guessed to be mixed with the partial pool boiling condition and the flow boiling condition from the previous results not published yet. So, we hope that the COP increase of refrigeration cycle will be verified and showed through this project.

  • PDF

Performance Analysis of Simultaneous Heating & Cooling Water Making System(I)-Simulation (냉.온열 동시 제조시스템의 성능분석(I)-Simulation)

  • Park, Seong-Ryong;Park, Jun-Tack;An, Young-Hun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.266-271
    • /
    • 2001
  • In this study, the performance of the simultaneous heating & cooling water making system using R134a was investigated by simulation. The most important effect upon heating COP was intermediate pressure depending on input water temperature. With the input water temperature of $10^{\circ}C\;and\;20^{\circ}C$, optimum intermediate pressure were 923 and 1040kPa, respectively. At that optimum intermediate pressure, the maximum heating COP of the system operated between $0^{\circ}C$ evaporating temperature and $70^{\circ}C$ condensing temperature were 4.15 and 3.83. With installation of the subcoolers in high or low pressure section, the system COP was increased by reducing the refrigerant mass flow rate. Under the optimum pressure and $10^{\circ}C$ input water temperature, it was found that heating COP was maximized when the low-subcooler and high-subcooler capacity rate were taken by 14% and 13%, respectively.

  • PDF

ON THE MINIMUM ORDER OF 4-LAZY COPS-WIN GRAPHS

  • Sim, Kai An;Tan, Ta Sheng;Wong, Kok Bin
    • Bulletin of the Korean Mathematical Society
    • /
    • v.55 no.6
    • /
    • pp.1667-1690
    • /
    • 2018
  • We consider the minimum order of a graph G with a given lazy cop number $c_L(G)$. Sullivan, Townsend and Werzanski [7] showed that the minimum order of a connected graph with lazy cop number 3 is 9 and $k_3{\square}k_3$ is the unique graph on nine vertices which requires three lazy cops. They conjectured that for a graph G on n vertices with ${\Delta}(G){\geq}n-k^2$, $c_L(G){\leq}k$. We proved that the conjecture is true for k = 4. Furthermore, we showed that the Petersen graph is the unique connected graph G on 10 vertices with ${\Delta}(G){\leq}3$ having lazy cop number 3 and the minimum order of a connected graph with lazy cop number 4 is 16.

흡수식 고효율화 방안

  • 문인식
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.3
    • /
    • pp.29-32
    • /
    • 2004
  • 이중효용 흡수냉동기의 고효율화 방안과 당사(한국 캐리어)에서 개발한 흡수식 냉동기를 소개 하고자 한다. 흡수냉동기는 1777년 영국의 NAIRNE에 의해 흡수냉동기 이론을 발표한 이후 1945년 미국 CARRIER사가 냉매로서 물, 흡수제로서 리튬브로마이드(LiBr)를 이용한 일중 효용 흡수냉동기가 세계 최초로 상용화되면서 공조용 및 산업용 냉방기기로서 보급되기 시작하였다. 이러한 흡수식 기술은 일본에서 이중효용 흡수냉동기 및 냉온수기를 개발하면서 공조용 및 산업용 냉. 난방기기로서 널리 보급되기 시작하였으며, 최근에는 고 효율 이중효용 흡수냉동기 및 냉온수기(COP 1.2-l.3)를 개발하여 제작. 판매하고 있으며 또한 삼중효용 흡수냉온수기(COP 1.6)를 개발하고 있다. 그리고 세계 흡수냉동기 시장은 일본 및 중국을 중심으로 고 효율 흡수냉동기 시장으로 재편되고 있다. 그러나, 우리나라에는 아직 일본기술에 의존한 표준 COP 이중효용 흡수냉동기 및 냉온수기(COP 1.01)를 제작 판매하고 있는 실정이다. 따라서 본 고에서는 이중효용 흡수냉동기의 고효율화 방안과 당사(한국 캐리어)에서 개발한 흡수식 냉동기를 소개하고자 한다.

  • PDF

Effects of Individual Components on the System Performance in a Desiccant Cooling System (제습냉방시스템에서 요소성능이 시스템성능에 미치는 영향)

  • Chang, Young-Soo;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.10
    • /
    • pp.687-694
    • /
    • 2007
  • Cycle simulation is peformed for two types of the desiccant cooling system incorporating a regenerative evaporative cooler. The cooling capacity and COP are evaluated at various effectiveness values of the regenerative evaporative cooler, the desiccant rotor and the sensible heat exchanger. As either of the effectiveness of the regenerative evaporative cooler or the humidity effectiveness of the desiccant rotor increases, both the cooling capacity and COP increase, but the enthalpy leak ratio gives the opposite effect on the system performance. It is found that COP of cycle A mainly depends on the humidity effectiveness of the desiccant rotor, while for cycle B enthalpy leak ratio of desiccant rotor has the major impact on COP. The effect of the sensible heat exchanger on the cooling capacity is small about 1/10 compared with those of other components.