• Title/Summary/Keyword: cooperation and circulation

Search Result 91, Processing Time 0.024 seconds

Preliminary Design of a Urban Transit Passenger Guidance System Using Congestion Management Model (혼잡관리 모형을 이용한 도시철도 이용객 동선유도시스템 기본설계)

  • Kim, Kwang-Mo;Park, Hee-Won;Kim, Jin-Ho;Park, Yong-Gul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3610-3618
    • /
    • 2015
  • The congestion of railway vehicle and station shows up to 220%. Especially, transfer resistance of passenger increase rapidly by the collision of circulation. So increment of travel time, occurrence of safety accidents act as a factor that inhibits the utilization of urban railway station. In this paper, to improve traveling speed and comfort of urban rail passengers, urban transit passenger guidance system using congestion management model is proposed. The congestion management model that can mitigate a recurring/non-recurring congestion is constructed and the preliminary design of the system (middleware system, control system, guidance drive system) is carried out. Passenger Guidance System is configured by step for changing the external data into a form usable by the algorithm, step to perform the congestion management algorithm using the real-time data and historical data, step to control device based on the value that is calculated by congestion management algorithm, step to drive the device based on the information in the control system and circulation guidance devices. In the future, detail design will be performed based on the preliminary design. A prototype of the various devices according to the station structures and locations will be made. The control module of guidance device will be developed.

Study for Flow Phenomenon in the Circulation Water Pump Chamber using the Flow-3D Model (Flow-3D 모형을 이용한 순환수취수펌프장 내 흐름현상 연구)

  • Ha, Sung-Won;Kim, Tae-Won;Choi, Joo-Hwan;Park, Young-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.580-589
    • /
    • 2019
  • Indonesia has a very short supply of electricity. As a solution to this problem, plans for construction of thermal power plants are increasing. Thermal power plant require the cooling water system to cool the overheated engine and equipment that accompany power generation, and the circulation water pump chamber among the cooling water system are generally designed according to the ANSI (1998) standard. In this study, the design criterion $20^{\circ}$ for the spreading angle of the ANSI (1998) of the layout of the circulating water pump chamber can not be satisfied on the K-coal thermal power plant site condition in Indonesia. Therefore, 3-D numerical model experiment was carried out to obtain a hydraulically stable flow and stable structure. The Flow-3D model was used as numerical model. In order to examine the applicability of the Flow-3D model, the flow study results around the rectangular structure of Rodi (1997) and the numerical analysis results were compared around the rectangular structures. The longitudinal velocity distribution derived from numerical analysis show good agreement. In order to satisfy the design velocity in the circulating water pump chamber, a rectangular baffle favoring velocity reduction was applied. When the approach velocity into the circulating water pump chamber was occurred 1.5 m/s ~ 2.5 m/s, the angle of the separation flow on the baffle was occurred about $15^{\circ}{\sim}20^{\circ}$. By placing the baffle below the separation flow angle downstream, the design velocity of less than 0.5 m/s was satisfied at inlet bay.

A Numerical Study on the Performance Analysis of a Solar Air Heating System with Forced Circulation Method (강제순환 방식의 공기가열식 태양열 집열기의 성능분석에 관한 수치해석 연구)

  • Park, Hyeong-Su;Kim, Chul-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.122-126
    • /
    • 2017
  • The aim of this study was to develop a device for solving the heating problem of living space using heated air, utilizing a simple air heater type collector for solar energy. At the present time, this study assessed the possibility of a development system through theoretical calculations for the amount of available energy according to the size change of the air-heated solar energy collector. To produce and supply hot water using the heat energy of the sun, hot water at $100^{\circ}C$ or less was produced using a flat or vacuum tube type collector. The purpose of this study was to research the air heating type solar collector that utilizes heating energy with heating air above $75^{\circ}C$, by designing and manufacturing an air piping type solar collector that is a simpler type than a conventional solar collector system. The analysis results were obtained for the generated air temperature ($^{\circ}C$) and the production of air (kg/h) to determine the performance of air heating by an air-heated solar collector according to the heat transfer characteristics in the collector of the model when a specified amount of heat flux was dropped into a solar collector of a certain size using PHOENICS, which is a heat flow analysis program applying the Finite Volume Method. From the analysis result, the temperature of the air obtained was approximately $40.5^{\circ}C$, which could be heated using an air heating tube with an inner diameter of 0.1m made of aluminum in a collector with a size of $1.2m{\times}1.1m{\times}0.19m$. The production of air was approximately 161 m3/h. This device can be applied to maintain a suitable environment for human activity using the heat energy of the sun.

An Analysis of the Thermal Flow Characteristics in Engine-Room and VTRU in accordance with Application of Thermoelectric Device Cooling System to Prevent Overheating of the Korean Navy Ship VRTU (해군 함정 VRTU의 과열방지를 위한 열전소자 냉각장치의 적용에 따른 기관실 및 VRTU 내부 열 유동특성 분석)

  • Jung, Young In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.610-616
    • /
    • 2020
  • This study conducted joint research with the Navy logistics command ship technology research institute to resolve the occurrence of naval vessel's high-temperature warning and equipment shutdown caused by VRTU overheating during summer operation and the dispatch of troops to equatorial regions. The cooling effect was checked according to the installation of a thermoelectric device cooling system, and heat flow and heat transfer characteristics inside VRTU was analyzed using Computational Fluid Dynamics. In addition, the temperature distribution inside the engine room was assessed through interpretation, and the optimal installation location to prevent VRTU overheating was identified. As a result, the average volume temperature inside the VRTU decreased by approximately 10 ℃ with the installation of the cooling system, and the fan installed in the cooling system made the heat circulation smooth, enhancing the cooling effect. The inside of the engine room showed a high-temperature distribution at the top of the engine room, and the end of the HVAC duct diffuser showed the lowest temperature distribution.

A Study on the Fire Drill Behavior Characteristics in Rehabilitation Center for Visually Impaired Persons (시각장애인 복지관의 화재 피난행태 특성분석 연구)

  • Lee, Jeong-Soo;Kwon, Heung-Soon;Kim, Eung Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5646-5653
    • /
    • 2015
  • This study focused on the architectural, interior and management guidelines in rehabilitation center for visually impaired persons. For these purposes, we reviewed the movement behaviors and the characteristics of fire drill in rehabilitation center for visually impaired persons. The results are as follows. : First, the liner circulation paths and interior landmarks are recommended, and dwelling units and program rooms should be located in ground floor for barrier free evacuation. Second, It is important to establish continuous handrail, variations of paving patterns and materials, good color definition, tactile informations and directional sound. Third, it is necessary to serve more specified architectural, interior, and management guidelines according to impaired prototypes.

Study of apartment plan technology adopting structural element of Hanok (공동주택에 적용 가능한 한옥 평면기술에 관한 연구)

  • Park, Kyung Hyun;Roh, Young-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.6366-6371
    • /
    • 2014
  • This study examined the structural elements of Korean-style houses (Hanok) and proposed formula accounting for their similar patterns and regular behavior. The design of modern apartment buildings adopts many aesthetic elements from Hanok but those are only for interior decoration. In this study, the projected Hanok eaves were examined in terms of the length of solar insolation. Leaning pillars toward the inside of the building were analyzed in detail not only for the front and back pillar, side pillar, but also the corner pillar. This study also suggested a design element from the Hanok structure, such as the elevated balcony, porch flooring, and inner garden in porch area. In addition, the new apartment plan improved air circulation, ventilation and natural lighting.

The Study of Development Skin Improvement Cosmetic By Spring Water of Onyang (온양온천수를 이용한 피부개선 화장품의 개발)

  • Shim, Seung-Bo;Oh, Seong-Geun;Chun, Yong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4257-4260
    • /
    • 2011
  • Hot spring water is underground water which naturally flows out to the earth's surface or is drilled for artificially and the water temperature should be higher than the region's average temperature for the year or underground water temperature of the earth's shallow strata of the region. Our nation stipulates that hot spring can be called if it is over $25^{\circ}C$. Generally, it is widely know that hot spring water has an effect on blood circulation, pain alleviation, soothing, and skin care and that its efficacy is mainly due to water temperature and a variety of minerals contained in water. The Onyang springs are the oldest spring district in our country and one of the most typical hot springs in this country. The current study found that there's no skin irritation through the skin irritation test applying hot spring water to cosmetic formulas, and that products using Onyang hot spring water showed an increase of 8.56% in epidermal water rate and a decrease of -67.74% in relative transepidermal water loss(TEWL), which indicates that cosmetics using Onyang hot spring water has an effecton skin improvement.

Quality Evaluations of Induction Motor Rotors during Die Casting Process II (유도전동기 회전자 금형주조 시 품질평가 II)

  • Park, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.347-352
    • /
    • 2019
  • This study focused on improving the cast quality of small-sized induction motor rotors during the die casting process. A new rotor core cast model was proposed based on previous research results and parametric studies. Numerical analyses using 3-dimensional half models were performed to evaluate the filling patterns of aluminum molten metals into a mold and on-site experiment performed to verify the newly proposed cast model. The following were obtained from numerical filling analyses and experimental results. First, molten metals started to fill the lower end ring, then moved on to fill the core slot and upper end ring and finally stopped to fill at the rotor core slot. Second, significant circulation of molten metals was not observed on the lower end ring, resulting in fewer defects at the section of the lower end ring from the experimental results. Third, the new shape of a rotor core cast was effective in producing rotors with sound cast quality, and reducing the end ring cast defect area by approximately 70 %.

A comparative study on the simulation of single-stage and multi-stage refrigeration cycle using propane as a refrigerant (프로판 냉매를 활용한 단일 및 다단 냉동 사이클의 전산모사 비교 연구)

  • Noh, Sanggyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3327-3335
    • /
    • 2014
  • In this study, comparison works have been performed for single-stage and multi-stage refrigeration cycle using propane as a refrigerant in order to cool down the natural gas stream. A comparative analysis has been performed for a single, two, three and four stage refrigeration cycle using propane as a refrigerant for cooling the natural gas stream. For the simulation, natural gas feedstock properties supplied by KOGAS were utilized and Peng-Robinson equation of state model was used. As the number of compression stages increase, the condenser heat duty is decreased. The refrigeration heat duty for a four-stage refrigeration cycle is decreased by 20.36% compared to that for a single-stage refrigeration cycle. Moreover, the total refrigerant circulation rate for a four-stage refrigeration system is was reduced by 14.53% compared to the single stage refrigeration cycle. The total compression power for a four-stage compression was reduced by 41.61% compared to the single stage compression.

Quality Evaluations of Induction Motor Rotors during Die Casting Process (유도전동기 회전자 금형주조 시 품질평가)

  • Park, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.115-120
    • /
    • 2018
  • This study examined the cast quality of small-sized induction motor rotors during the die casting process. Numerical analyses with 3-dimensional half models were performed to investigate the filling patterns of aluminum molten metals into a mold after high-speed injections. The following were obtained from numerical analyses and experimental results. First, molten metals started to fill the lower end ring, then moved horizontally to fill the core slot and upper end ring, and finally stopped to fill the rotor core slot. Second, circulation of molten metals occurred at the lower end ring, resulting considerable porosity at the section of lower end ring from the experimental results. Third, further work for obtaining sound quality of rotor core cast is required to develop a new shape of the rotor core cast or improve the die casting conditions.