• Title/Summary/Keyword: cooling temperature

Search Result 4,657, Processing Time 0.036 seconds

Changes in the External Heat Environment of Building Evaporative Cooling Systems in Response to Climate Change (기후변화 대응 건축물 기화냉각시스템 적용에 따른 외부 열환경 변화 연구)

  • Yoon, Yong-Han;Kwon, Ki-Uk
    • Journal of Environmental Science International
    • /
    • v.27 no.12
    • /
    • pp.1261-1269
    • /
    • 2018
  • The purpose of this study was to investigate changes in the external thermal environment, following the application of evaporative cooling systems in buildings, in response to climate change. In order to verify changes in the external thermal environment, a T-test was performed on the microclimate, Thermal Comfort Index (TCI), and building surface temperature. Differences in microclimate, following the application of the evaporative cooling system in the building, were significant in terms of temperature and relative humidity. In particular, temperature decreased by more than 7% when the evaporative cooling system was applied. According to the results of the Thermal Comfort Index analysis, the Wet-Bulb Globe Temperature (WBGT) was below the limit of outdoor activities, indicating that outdoor activities were possible. The Universal Thermal Climate Index (UTCI) values were within the very strong heat stress range when the evaporative cooling system was not applied, When the system was applied, the UTCI values were within the strong heat stress range, indicating that they were lowered by one level. The building surface temperature decreased by ~10% or more when the evaporative cooling system was applied, compared to when it was not applied. Finally, the outside surface temperature of the building decreased by ~12% or more when the system was applied, compared to when it was not applied. We conclude that the energy saving effect of the building was significant.

Performance Test of Cooling System for the KEPCO HTS Power Cable (한전 초전도전력케이블 냉각시스템 성능시험)

  • Yang, H.S.;Kim, D.L.;Sohn, S.H.;Lim, J.H.;Choi, H.O.;Lee, B.S.;Choi, Y.S.;Ryoo, H.S.;Hwang, S.D.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2206-2210
    • /
    • 2007
  • As a power transmission line supplying power to a densely populated city, the high temperature superconducting (HTS) cable is expected to one of the most effective cables with a compact size because of its high current density. The verification of HTS power cable system have been progressed by KEPRI. A cooling system for a 3-phase 100m HTS power cable with 22.9kV/1.25kA was installed and tested at KEPCO's Gochang power testing center in Korea. The system consists of a liquid nitrogen decompression cooling system with a cooling capacity of 3kW and a closed circulation system of subcooled liquid nitrogen. Several performance tests of the cable system with respect to the cooling such as cooling capacity, heat load and temperature stability, were performed at several temperatures. Thermal cycle test, cool-down to liquid nitrogen temperature and warm-up to room temperature, was also performed to investigate thermal cycle influences. The outline of the installed cooling system and performance test results are presented in this paper.

  • PDF

Local Cooling of the Limbs in $37^{\circ}C$ Ambient Temperature (사지부의 냉각효율성에 관한 연구)

  • Hwang, Kyoung-Sook;Choi, Jeong-Wha;Lee, Kyung-Suk
    • The Korean Journal of Community Living Science
    • /
    • v.18 no.1
    • /
    • pp.87-95
    • /
    • 2007
  • This study was to determine the effect of cooling parts of the limbs without harm to health. The results provide basic data for the development of clothing which could increase work efficiency and reduce body strain in hot environments. Five male adults took part in the study, conducted in a climate chamber with an ambient temperature of $37^{\circ}C$ and a relative humidity of 50%. The limbs were divided into six areas to be cooled: upper arm, forearm, thigh, calf, hand, and foot. According to preceding studies, permissible cooling safety limits of skin temperature for each part of the body for one-hour were $20^{\circ}C$ on the upper arm, forearm, thigh, and calf, and $23^{\circ}C$ on the hand and foot. For this reason, cooling the skin of each region was carried out at the above mentioned temperatures. In conclusion, cooling the hand and foot reduced perspiration, rectal temperature and heart rate. Therefore, the heat stress of workers exposed to hot environments would be reduced by decreased subjective sensations of heat and increased comfort. The effectiveness of cooling was better on the arm than on the leg.

  • PDF

Numerical Simulation of Temperature and Stress Distribution in Mass Concrete with pipe cooling and Comparision with Experimental Measurements (매스콘크리트 시험체의 수화열 해석 및 실험)

  • 주영춘;김은겸;신치범;조규영;박용남
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.269-274
    • /
    • 1999
  • Various method have been developed for mass concrete structures to reduce the temperature increase of concrete mass due to exothermic hydration reactions of concrete compounds and thereby to avoid thermal cracks. One of the methods widely acceptable for practical use is pipe cooling, in which cooling is achieved by circulating cold water through thin-wall steel pipes embedded in the concrete. A numerical simulation was performed to investigate the effectiveness of pipe cooling. A three-dimensional finite element method was proposed to analyse the transient three-dimensional heat transfer between the hardening concrete and the cooling water in pipe and to predict the stress development during the curing process. The effects of the cement type and content and the environment were taken into consideration by the heat generation rate and the boundary conditions, respectively. In order to test the validity of the numerical simulation, a model RC structure with pipe cooling was constructed and the time-dependent temperature and stress distributions within the structure as well as the variation of the temperature of cooling water along the pipe were measured. The results of the simulation agreed well the experimental measurements. The results of this study have important implications for the optimal design of the cooling pipe layout and for the estimation of thermal stress in order to eliminate thermal cracks.

  • PDF

A Study on the Combined Equipment for the Pre-cooling and the Thawing using the Low Temperature Vacuum System (저온진공기술을 이용한 예냉 및 해동 겸용장치에 관한 연구)

  • 김성규;박영승;최현규;이정혜;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.280-288
    • /
    • 2003
  • We need refrigeration system which can maintain the freshness of agricultural products, because of being distance from a tiller to a consumer. Vacuum Pre-cooling system has an advantage in quality maintenance through vapid cooling down by using latent heat of evaporation of stored products. A number or thawing methods in current use have also several disadvantages in thawing time. discoloration mass loss caused by drying, capital costs and running cost. These damages are, it is claimed, either eliminated or improved by the vacuum thawing system. An experimental study on the pre-cooling for the bean sprouts and cabbage, and thawing for hairtail and croaker by the low temperature vacuum system were carried out. The cabbage cooling time with this Pre-cooling vacuum system took about 60 minutes to reach from $23.2^{circ}C to 4.5^{\circ}C$ at 5 mmHg abs. ($6.66\times10^{-4}$ MPa). The croaker thawing time with this low temperature vacuum thawing system took about 170 minutes to reach from $-10.3^{circ}C to -0.8^{\circ}C$ at 20 mmHg abs ($2.67\tiems10^{-3}$MPa). The vacuum Pre-cooling and thawing system have merits compared with present systems in their short intervals to cool down and to thaw without any quality losses.

Improving the power of PV module by a surface cooling system (표면냉각을 통한 PV 모듈의 출력 향상에 관한 연구)

  • Kim, Dae-Hyun;Kim, Dong-Jun
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.88-93
    • /
    • 2009
  • This study was conducted to improve the power of PV module using a surface cooling system One of the unique characteristics of PV module is power drop as a module surface temperature increases due to the characteristics of crystalline silicon used in a solar cell. To overcome the output power reduction by temperature effect, module surface cooling using water circulation was performed. By cooling effect, module surface temperature drops maximally $20.3^{\circ}C$ predicting more than 10% power enhancement. Maximum deviation of voltage and current between a control and cooled module differed by 5.1 V and O.9A respectively. The maximum power enhancement by cooling system was 12.4% compared with a control module. In addition, cooling system can wash the module surface by water circulation so that extra power up of PV module can be achieved by removing particles on the surface which interfere solar radiation on the cells. Cooling system, besides, can reduce the maintenance cost and prevent accidents as a safety precaution while cleaning works. This system can be applied to the existing photovoltaic power generation facilities without any difficulties as well.

Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor (인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

Film Cooling from Two Rows of Holes with Opposite Orientation Angles: Blowing Ratio Effects (반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성 : 분사비의 영향)

  • Ahn, J.;Jung, I.S.;Lee, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.113-118
    • /
    • 2000
  • Experimental results describing the effects of blowing ratio on film cooling from two rows of holes with opposite orientation angles are presented. The inclination angle was fixed at $35^{\circ}$ and the orientation angles were set to be $45^{\circ}$ for downstream row. and $-45^{\circ}$ for upsream row. The studied blowing ratios were 0.5, 1.0 and 2.0. The boundary layer temperature distributions were measured using thermocouple at two downstream loundary layer temperature distributions were measured using thermocouple at two downstream locations. Detailed adiabatic film cooling effectiveness and heat transfer coefficient distributions were measured with TLC(Thermochromic Liquid Crystal). The adiabatic film cooling effectiveness and heat transfer coefficient distributions are discussed in connection with the injectant behaviors inferred from the boundary layer temperature distributions. Film cooling performance, represented by heat flux was calculated with the adiabatic film cooling effectiveness and heat transfer coefficient data.

  • PDF

Developing Optimal Pre-Cooling Model Based on Statistical Analysis of BEMS Data in Air Handling Unit (BEMS 데이터의 통계적 분석에 기반한 공조기 최적 예냉운전 모델 개발)

  • Choi, Sun-Kyu;Kwak, Ro-Yeul;Goo, Sang-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.467-473
    • /
    • 2014
  • Since the operating conditions of HVAC systems are different from those for which they are designed, on-going commissioning is required to optimize the energy consumed and the environment in the building. This study presents a methodology to analyze operational data and its applications. A predicted operation model is to be produced through a statistical data analysis using multiple regressions in SPSS. In this model, the dependent variable is the pre-cooling time, and the independent variables include the power output of the supply air inverter during pre-cooling, the supply air set temperature during pre-cooling, the indoor temperature-indoor set temperature just before pre-cooling, supply heat capacity, and the lowest outdoor air temperature during non-cooling/non-heating hours. The correlation coefficient R2 of the multiple regression model between the pre-cooling hour and the internal/external factors is of 0.612, and this could be used to provide information related to energy conservation and operating guidance.

Improving the power of PV module by a surface cooling system (표면냉각시스템을 이용한 PV 모듈의 출력 향상)

  • Lee, Jong-Hwan;Lee, Jae-Ung;Kim, Dong-Jun;Kim, Dae-Hyun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.309-313
    • /
    • 2009
  • This study was conducted to improve the power of PV module using a surface cooling system. One of the unique characteristics of PV module is power drop as a module surface temperature increases due to the characteristics of crystalline silicon used in a solar cell. To overcome the output power reduction by temperature effect, module surface cooling using water circulation was performed. By cooling effect, module surface temperature drops maximally $20.3^{\circ}C$ predicting more than 10% power enhancement. Maximum deviation of voltage and current between a control and cooled module differed by 5.1V and 0.9A respectively. The maximum power enhancement by cooling system was 12.4% compared with a control module. In addition, cooling system can wash the module surface by water circulation so that extra power up of PV module can be achieved by removing particles on the surface which interfere solar radiation on the cells. Cooling system, besides, can reduce the maintenance cost and prevent accidents as a safety precaution while cleaning works. This system can be applied to the existing photovoltaic power generation facilities without any difficulties as well.

  • PDF