Film Cooling from Two Rows of Holes with Opposite Orientation Angles: Blowing Ratio Effects

반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성 : 분사비의 영향

  • 안준 (서울대학교 대학원) ;
  • 정인성 (서울대학교 터보.동력기계 연구소) ;
  • 이준식 (서울대학교 기계항공공학부)
  • Published : 2000.04.20

Abstract

Experimental results describing the effects of blowing ratio on film cooling from two rows of holes with opposite orientation angles are presented. The inclination angle was fixed at $35^{\circ}$ and the orientation angles were set to be $45^{\circ}$ for downstream row. and $-45^{\circ}$ for upsream row. The studied blowing ratios were 0.5, 1.0 and 2.0. The boundary layer temperature distributions were measured using thermocouple at two downstream loundary layer temperature distributions were measured using thermocouple at two downstream locations. Detailed adiabatic film cooling effectiveness and heat transfer coefficient distributions were measured with TLC(Thermochromic Liquid Crystal). The adiabatic film cooling effectiveness and heat transfer coefficient distributions are discussed in connection with the injectant behaviors inferred from the boundary layer temperature distributions. Film cooling performance, represented by heat flux was calculated with the adiabatic film cooling effectiveness and heat transfer coefficient data.

Keywords