• Title/Summary/Keyword: cooling system

Search Result 4,064, Processing Time 0.032 seconds

Development of the Wearable Personal Cooling System (착용형 개인 냉방시스템 개발)

  • Jang, Jun-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.2872-2877
    • /
    • 2012
  • This paper discusses the development of the wearable personal cooling system for reducing thermal stress in hot environment. The personal cooling system is operated with the compact refrigeration system by compressing refrigerant. The compact refrigeration system is applied with the miniaturization and weight reduction for portable and wearable cooling system. The body heat is reduced by heat conduction with evaporator in direct cooling type. The cooling capacity of the wearable personal cooling system is approximately 100W and, the system could maintain the inside temperature of approximately 12-$13^{\circ}C$ lower than the ambient temperature. The weight of the wearable cooling system is about 3kg including vest, case, battery and all parts.

A Study on the cooling system design for electric propulsion system in submarine (수중체 전기추진시스템용 냉각체계 설계에 관한 연구)

  • Oh, Jin-Seok;Jung, Sung-Young
    • Journal of Navigation and Port Research
    • /
    • v.36 no.1
    • /
    • pp.35-41
    • /
    • 2012
  • In this paper, we analyze the current submarine cooling system and study control algorithms for cooling system. Cooling system are installed in the submarine propulsion motor to protect the motor from high-temperature by iron loss and copper loss. The cooling system control the sea water and fresh water pump RPM to keep the motor temperature stable by external environment and motor RPM holding time. The cooling system simulation program is made for checking the cooling performance, and simulation is performed with various control strategy. The results with proposed cooling algorithm is shown to improve the thermal stability and efficiency of cooling system.

Development of simulation program for automotive engine cooling system (엔진 냉각 시스템의 이론적 시뮬레이션 프로그램 개발)

  • Lee, Seung-Hee;Sin, Chang-Hoon;Park, Won-Gyu;Yang, Jang-Sik;Kim, Eun-Pil;Seo, Jeong-Sik
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.341-346
    • /
    • 2000
  • A numerical simulation has been carried out for the engine cooling system. It is the important element to analysis of heat transfer process in cooling system for an automotive engine. Thus, the purpose of this simulator is to present useful information at the early stages of the design of the cooling system by enabling the development engineer to predict performance trends. This program has useful window interface for analysis of the cooling system and it is convenient for user to control data with relational database. The system was simulated and compared with experimental data. As a result, the inlet, outlet temperature of the radiator by the simulator agrees well with it. It is concluded that this simulation program is available in developing the cooling system for a new car.

  • PDF

Hydartion Heat Control with Closed Loop Pipe Cooling System (냉각수 순환 형태의 파이프 쿨링 공법을 이용한 매스콘크리트 수화열 제어)

  • 박찬규;손상현;이승훈;장기욱;정재홍;김명식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.403-408
    • /
    • 2001
  • In order to control hydration heat in mass concrete, pipe cooling method has been widely used. However, open pipe cooling system cannot be applied to the mass concrete structures when cooling water supply is difficult. To control hydration heat of high strength mass foundation, closed loop pipe cooling system was developed to solve the cooling water supply. This paper reports the performance result of hydration heat control with closed loop pipe cooling system.

  • PDF

Development of Rapid Cooling System for Injection Mold (사출금형의 급속냉각시스템 개발)

  • Moon, Young-Bae;Choi, Youn-Sik;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.8 no.1
    • /
    • pp.31-34
    • /
    • 2014
  • The Injection molding is used more than 70% of total production in plastic products. The injection molding process has 4 processes such as filling, packing, cooling and ejecting. It spends most of times in the cooling process. Therefore, it is important to control the mold temperature in producing plastic products. The cooling system and time affect the product's quality and productivity. Especially, cooling time has about 60% of total injection cycle time. Therefore, we can improve a productivity by shortening cooling time. In this study, the rapid cooling system was developed and performed a efficiency test. This system could refrigerate coolant to $1^{\circ}C$ and had to need 10 minutes for normal operating. However, if response time of temperature controller and sensor will be increased, the performance of this system will increase.

  • PDF

Development of Rapid Cooling System for Injection Mold (사출금형의 급속냉각시스템 개발)

  • Moon, Young-Bae;Choi, Youn-Sik;Jeong, Yeong-Deug
    • 한국금형공학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.111-114
    • /
    • 2008
  • The Injection molding is used more than 70% of total production in plastic products. The injection molding process has 4 processes such as filling, packing, cooling and ejecting. It spends most of times in the cooling process. Therefore, it is important to control the mold temperature in producing plastic products. The cooling system and time affect the product's quality and productivity. Especially, cooling time has about 60% of total injection cycle time. Therefore, we can improve a productivity by shortening cooling time. In this study, the rapid cooling system was developed and performed a efficiency test. This system could refrigerate coolant to $1^{\circ}C$ and had to need 10 minutes for normal operating. However, if response time of temperature controller and sensor will be increased, the performance of this system will increase.

  • PDF

The Study of Comparison of Cooling System for H2 Discharge Station (수소충전용 직접 및 간접 냉각시스템 비교 평가 연구)

  • LEE, HYENCHAN;YI, JONGYEOL;BAE, CHANHYO;HEO, JEONGHO;JEON, JAEYOUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.2
    • /
    • pp.163-169
    • /
    • 2019
  • This study is a research to compare efficiency of new cooling system (chiller, pre-cooler) to that of the conventional system at the hydrogen refueling station (HRS). This study includes contents for thermodynamic comparison of cooling system for HRS and comparison of pros and cons of its components. So It is to establish design concept of cooling system of HRS supplying with fuel cell electric vehicle (FCEV). HRS is charging high pressure H2 (700 bar) to FCEV. However cooling system is need to prevent temperature rise in tank. This cooling system consists of pre-cooler and chiller system.

A Study on the Performance of Thermoelectric Cooling System for Design Parameters of the Cooling Jacket (냉각재킷의 설계인자에 따른 열전냉각장치의 성능에 관한 연구)

  • Park, Sang-Hee;Lee, Jeong-Eun;Kim, Kyoung-Jin;Kim, Dong-Joo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.149-156
    • /
    • 2009
  • A small-scale thermoelectric cooling system was built in an effort to enhance the performance of the refrigeration system by utilizing the water-cooled jacket which was attached to the hot side of the thermoelectric module. Considered design parameters for the water-cooled jacket were the geometry of the flow passage inside the jacket and the flow rate of cooling water. The higher flow rate of cooling water in the jacket resulted in a better performance of the refrigeration system. The increase in the number of channels for water flow passage inside the cooling jacket also showed significant improvement on the performance of the thermoelectric cooling system such as the cooling capacity and the COP of the refrigeration system.

A Study on the Operation Strategy of Radiant Floor Cooling in Apartment Buildings (공동주택에서 바닥복사냉방의 적정 운영방안에 관한 연구)

  • 조영흠;석호태;여명석;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.574-583
    • /
    • 2004
  • In this study, the operation strategy of the radiant floor cooling is evaluated in terms of indoor environmental conditions and energy consumption through simulations using the TRNSYS comparing the existing cooling operation. The operation strategy during continuously operated for cooling is proposed that a representative room had additional equipments and other rooms were operated with only a radiant floor cooling system and that system and control method for cooling are varied with period while intermittently operated for cooling. Specifically, when there are no people in the room, rooms were operated by only radiant floor cooling system using cooling storage and when people are occupied, rooms were operated by dehumidification and supplementary cooling device with radiant floor cooling system. The results of this study show that proposed operation strategy can stably maintain the set room air temperature and can reduce the energy consumption compared to the existing cooling method during continuously operated for cooling. While intermittently operated for cooling, the difference of set room air temperature by proposed operation strategy does not happen, satisfying comfort standards and the radiant floor cooling can expect to supply stable electric power because of decreasing demand for peak electric power of energy consumption.

Prediction of Tool Life on Cooling System in Warm Forging (온간 단조에서의 냉각방법에 따른 금형 수명 예측)

  • 이현석
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.04a
    • /
    • pp.67-70
    • /
    • 2000
  • The tool life is not long enough under sever forming condition in warm forging. The tool life is affected by wear heat fatigue plastic deformation and so on. Especially wear is one of the most serious factors for tool life. To increase tool life we should consider various factors like processing design die design die materials lubrication and cooling system This study design to obtain the steady state temperature of die by FEM analysis under several conditions of cooling. There are four cooling conditions in this study no cooling internal cooling external cooling and both internal and external cooling. With above obtained temperatures tool life is predicted using Archard's model that is considered softening of die. The effect of internal cooling system is better than that of externally cooled die. To predict the die life the steady state temperature is calculated by using mean temperature of die. Considering only wear the die life much longer as the cooling effect is bigger. The more accurate die life will be predicted if we consider heat crack as well as wear.

  • PDF