• 제목/요약/키워드: cooling power load

검색결과 235건 처리시간 0.029초

실시간 일정압력 제어기술을 적용한 냉난방장치의 피크부하 저감과 에너지 효율 향상을 위한 시스템 개발 (Development of Heating and Cooling System with New Heat Exchange Cycle for High Efficiency and Peak Power Reduction Using Real time Constant Refrigerant Pressure Control)

  • 최선영;이영국;최명광;최태원
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.53-58
    • /
    • 2015
  • Systemic heating and cooling air conditioning systems are popular in various industrial fields and even home. Recently, the rate of supply of this kind of multi-heat pump has been increased under ESCO financing supporting system. Generally the heat pumping system has a structural simplicity and easy installation benefits. and has good running efficiency under normal designed condition. But under extreme climate condition (over $+30^{\circ}C$, under $-10^{\circ}C$), this system exposes abnormal power consumption. It causes high progressive electric power rates and resultant peak power capacity of power plant. In this paper, a novel system concept of buffering refrigerant accumulator and constant pressure control system to relieve peak power load is proposed and this system's utility is verified with an prototype experimental system.

EnergyPlus 해석용 수랭식 VRF 히트펌프의 냉·난방 능력 및 소비전력 예측식 산출 기법 (Capacity and Power Input Performance Curves Creation of Water-cooled VRF Heat Pump for EnergyPlus)

  • 김민지;권혁주;이광호
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권3호
    • /
    • pp.1-8
    • /
    • 2017
  • Variable refrigerant flow (VRF) systems have recently attracted attention in many countries due to a variety of advantages over conventional system. Especially, the water-cooled VRF heat pump, including geothermal heat pump, is a system that accurately controls the flow rate of refrigerant for the improved efficiency under part load operation. This paper describe the process of generating the cooling and heating energy performance curve coefficients and performance expressions for modeling water cooled VRF system using EnergyPlus. Through this study, the process for generating performance curves can be implemented into EnergyPlus or other comparable building energy analysis tools for the long-term evaluation of heat pump under dynamic conditions.

${\cdot}$난방 시스템의 부하관리 프로그램 적용 타당성 검토 (feasibility Study in Application on Load Management of Cooling or Heating Systems)

  • 손학식;김회철;김형중;허동렬;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.686-688
    • /
    • 2004
  • We suggest that the core factor which can be established successfully pushing ahead with domestic load management program is finding and keeping management of controllable load resources. We know that load management is mostly the maximum demand power management and participation of DLC program. This paper suggests the way coping with load management suggesting model which air conditioning and heating load facilities are applied to DU program.

  • PDF

전자장비 냉각을 위한 2상 순환형 써모사이폰 시스템의 성능에 대한 실험적 연구 (The Experimental Study on the Performance of Two-Phase Loop Thermosyphone System for Electronic Equipment Cooling)

  • 강인석;최동규;김택영
    • 대한기계학회논문집B
    • /
    • 제28권4호
    • /
    • pp.415-424
    • /
    • 2004
  • Cooling the electronic equipment is one of the major focal points of the design process and the key to successful product launch. The two-phase loop thermosyphone which is a good candidate among many available options was investigated fur cooling of the high power amplifiers. The system is composed of evaporator which contains 6 parallel cold plates, fan cooled condenser, gas-liquid separator, and interconnecting tubes. Experiments were performed for several refrigerant charging values, hs and as a experiment result, the optimum charging value fur this system was proposed. In order to optimize the system design, the operating cycle pressure and inlet/outlet temperatures of evaporator and condenser are measured and analyzed. The effect of the three parameters such as flow rate and temperature of condenser cooling air, and thermal load on the evaporator are investigated. The lower the operating pressure and the cycle temperatures are also better to prevent the leakage of the system. The system invesigated in this paper can be directly used for cooling of a real unmanned wireless communication station.

소형 오존발생장치의 전력제어와 냉각효과에 관한 연구 (A Study on Cooling Effect and Power Control of a Mini Ozonizer)

  • 우성훈;박승조;윤성윤;박지호;우정인
    • 대한환경공학회지
    • /
    • 제28권1호
    • /
    • pp.97-103
    • /
    • 2006
  • 본 논문은 미세 오존 출력을 얻을 수 있는 자동제어형 오존발생장치의 제어기법을 제시하고, 또한 무성방전에 의한 오존발생장치의 유입공기를 공극에서 저온인 $2^{\circ}C$까지 냉각 하여 포화 확산도가 높은 고밀도 탈취용 오존을 발생시킬 수 있는 기법을 제시한다. 고주파수의 오존방전 노이즈에 의한 전원파형의 불량화를 보상하기 위해서 디지털 궤환 제어시스템을 구성하고, 방전관의 등가 커패시터의 전압과 전류를 검출하여 2중의 제어루프를 설계한다. 부하변동에 따르는 과도상태 응답특성을 개선하고 제어기의 연산 지연시간을 보상하기 위하여 연산시간을 전원장치 플랜트의 고유한 파라미터로 가정하여 플랜트모델에 포함시켜 모델링한다. 제안된 오존 발생기는 고농도 고효율의 오존방전 시스템의 입력전원에서 고주파방전노이즈가 제거되어 정현적으로 되며 2배 이상의 안정된 오존출력을 얻는 것을 실험적으로 입증한다.

Thermal analysis and optimization of the new ICRH antenna Faraday Screen in EAST

  • Q.C. Liang ;L.N. Liu ;W. Zhang ;X.J. Zhang ;S. Yuan ;Y.Z. Mao ;C.M. Qin;Y.S. Wang ;H. Yang
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2621-2627
    • /
    • 2023
  • In Experimental Advanced Superconducting Tokamak (EAST) experiments, to achieve long pulse and high-power ICRH system operation, a new kind of ICRH antenna has been designed. One of the most critical factors in limiting the operation of long pulse and high power is the intense heat load in the front face of the ICRH antenna, especially the Faraday Screen (FS). Therefore, the cooling channels of FS need to be designed. According to thermal-hydraulic analysis, the FS tubes are divided into several groups to achieve more excellent water cooling capability. The number of series and parallel tubes in one group is chosen as six. This antenna went into service in the spring of 2021, and it is delightful that the temperature distribution of the FS tube is below 400 ℃ in 14.5 s and 1.8 MW ICRH system operation. However, the active water-cooling design was not carried out on the upper and lower plates of FS, which led to severe ablations on that region under long pulse and high power operation, and the temperature is up to 800. Therefore, the upper and lower side plates of the FS were designed with water cooling based on thermal-hydraulic analysis. During the 2022 winter experiments, the temperature of ICRH antenna FS was lower than 400 in the pulse of 200s and the power of 1 MW operation.

직접 분사식 소형 과급 디젤엔진의 운전조건이 배기 배출물에 미치는 영향 (An Effect of Operating Conditions on Exhaust Emissions in a Small Turbocharged D.I. Engine)

  • 장세호;고대권;안수길
    • 동력기계공학회지
    • /
    • 제6권2호
    • /
    • pp.12-17
    • /
    • 2002
  • Recently, the world is faced with very serious problems related to the air pollution due to the exhaust emissions of the diesel engine. So, many of researchers have studied to reduce the exhaust emissions of diesel engine. This study was investigated for various exhaust emissions according to operating conditions in a turbocharged D.I. diesel engine. As a result of experiments in a test engine, the $CO_2\;and\;NO_x$ increased with increasing load, the $CO_2$ and CO decreased with increasing charge air pressure in manifold, the CO decreased with increasing cooling fresh water temperature, and the $NO_x$ decreased with worming cooling fresh water before engine start.

  • PDF

직접 분사식 디젤엔진에서 EGR이 배기배출물에 미치는 영향에 관한 연구 (The Effect of EGR on Exhaust Emissions in a Direct Injection Diesel Engine)

  • 장세호
    • 동력기계공학회지
    • /
    • 제8권1호
    • /
    • pp.18-23
    • /
    • 2004
  • The direct injection diesel engine is one of the most efficient thermal engines. For this reason DI diesel engines are widely used for heavy-duty applications. But the world is faced with very serious problems related to the air pollution due to the exhaust emissions of diesel engine. So, that is air pollution related to exhaust gas resulted from explosive combustion should be improved. Exhaust Gas Recirculation(EGR) is a proven method to reduce NOx emissions. In this study, the experiments-were performed at various engine loads while the EGR rates were set from 0% to 20%. The emissions trade-off and combustion of diesel engine are investigated. Hot and cooled EGR are achieved without cooling and with cooling respectively. It was found that the exhaust emissions with the EGR system resulted in a very large reduction in oxides of nitrogen at the expense of higher smoke emissions. Also, the reduction rates of NOx emissions for hot and cooled EGR are similar at load 20%.

  • PDF

실내온도조절을 위한 인버터 열펌프의 주파수 제어에 관한 연구 (A study of frequency control of an inverter heat pump for indoor air temperature adjustment)

  • 박윤철;민만기
    • 대한기계학회논문집B
    • /
    • 제21권10호
    • /
    • pp.1262-1272
    • /
    • 1997
  • An experimental study on the frequency control of an inverter heat pump to get the desired indoor room temperature has been conducted for the performance characteristics during the steady, 4, 8, and 16 step frequency operations. The heat pump model used in this study was operated to meet the experimental conditions of ASHRAE standard. The performance of the system was tested by measuring the temperature and pressure of the refrigerant, and cooling capacity, power consumption, etc. of the system. As the controlling frequency steps increased, the running time of the compressor increased as well as the electric consumption of the system and the cooling energy due to the wall heating load. However, the average cooling COP was improved.