• 제목/요약/키워드: cooling loads

검색결과 282건 처리시간 0.027초

TAC를 반영한 BIN 데이터 기반의 냉난방 부하 변화에 관한 연구 (Heating and Cooling Load Evaluation Study with TAC Based BIN Data)

  • 이광섭;김유진;민경천;이의준;강은철
    • 설비공학논문집
    • /
    • 제29권9호
    • /
    • pp.463-471
    • /
    • 2017
  • According to the Korea industrial standard of air conditioning systems (KS C 9306), cooling and heating loads for buildings can be calculated by using maximum and minimum temperature in BIN data. Cooling and heating loads can be determined by building set temperature and ambient temperature. Cooling and heating system capacity of buildings can be normally designed according to determined heating and cooling loads. Cooling and heating system capacity can be reduced by updated BIN data, applying TAC (Technical Advisory Committee) values. In this study, updated BIN data have been analyzed using ambient temperature of 19 areas in Korea for the last 10 years (2005~2014) provided by KMA (Korea Meteorological Administration). Building cooling and heating loads have been calculated following TAC based BIN data. As a result, designed system capacity decreased depending on applying TAC. Those were reduced as 7.1% ($100m^2$ building), 8.7% ($1,000m^2$ building) in cooling capacity, 11.7% in heating capacity when TAC 2.5% applied. And also, it is expected system initial and operating cost by decreasing system capacity.

에너지절약형 주택에서의 단열차양 적용과 제어방법에 따른 냉난방부하 분석 (An Analysis of Heating and Cooling Loads by Insulated Shades and Control Method in an Energy Saving Apartment)

  • 박선효;권경우;손장열
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.392-397
    • /
    • 2010
  • Energy loss from windows accounts for large scores of heating and cooling loads also in energy saving apartments that is reduced over 30% of total energy consumption. Movable reflective insulations, insulation shutters, blinds, insulated shades are used to reduce energy loads from windows. In this study, energy saving performance of insulated shades was simulated by control methods. According to installation of insulated shades, heating loads were decreased about 10.5~11.3%, and cooling loads are decreased about 29.1~38.3% on an energy saving apartment. The heating peak load was reduced about 9.5% by insulated shades and the cooling peak load was reduced about 25.7~31.5%. In the case of insulated shades with automatic control system, simple time schedule control system would be more efficient than outdoor detection control system that should use several sensors.

수정빈법을 이용한 냉난방부하 예측 프로그램 개발 (Developing The Prediction Program of Heat and Cooling Loads by Modified Bin Methods)

  • 이면극;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제21권4호
    • /
    • pp.21-28
    • /
    • 2001
  • It is a time since sustainable architecture become a main issue of design concept in 21C. However, it is necessary to develope the tool estimating energy loads and uses in our architectural conditions for energy saving design. This study aims to develope the E-Load program to predict heat and cooling loads of houses. The program is developed by modified bin methods derived from ASHRAE TC 4.7. It consists of 4 divisions such as files, data inputs, energy load estimations and output options. The main processes of energy load estimations are based on ASHRAE fundamentals. The developed E-Load program is a easy and valid tool to predict heat and cooling loads of buildings.

  • PDF

시험공간에 대한 냉방부하 실증실험 및 계산 (Verification Experiment and Calculation of Cooling Load for a Test Space)

  • 유호선;현석균;김용식;홍희기
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.641-651
    • /
    • 2003
  • In order to assess the reliability of a building energy simulation program (TRNSYS) from the standpoint of user, a set of verification experiment and calculation of cooling load for a test space is carried out. This work is a complement of the previous study that dealt with heating load for the same space. The test space is kept airtight to eliminate the source of uncertainties in modeling. A window-mounted, on/off controlled air-conditioner is used for cooling, whose performance has been established a priori. The calculation encompasses two models for evaluating cooling load in TRNSYS: energy rate control and temperature level control. Comparison of the total cooling loads obtained from different sets of experimental data enables to validate the measurements. The experimental result shows that the latent load is fairly large even in the absence of apparent air change in the space, which needs to be clarified. Each of hourly and daily accumulated sensible loads is compared between the experiment and two calculation models. Despite an inconsistency associated with solar irradiation, both of the models agree favorably with the experiment within a tolerance, illustrating their capability of properly predicting space thermal loads.

베네시안 블라인드가 적용된 오피스 건물의 외피 투과체 계획을 위한 열·빛 환경 평가에 대한 연구 (Evaluation of Thermal and Visual Environment for the Glazing and Shading Device in an Office Building with Installed of Venetian Blind)

  • 김철호;김강수
    • KIEAE Journal
    • /
    • 제15권6호
    • /
    • pp.101-109
    • /
    • 2015
  • Purpose: Glazing and shading devices influence a lot on the thermal and visual environment in office buildings. Solar heat and daylight are contrary concept, therefore proper arrangement of thermal and optical performance is needed when designing a glazing and shading devices. The purpose of this study is to examine the conditions of the glazing and shading devices available for promoting the reduction of cooling loads + lighting loads and the improvement in thermal comfort and visual comfort for the summer season in an office building installed with venetian blind. Method: This study established 12 simulation cases which have different glazings and the positions of venetian blind for evaluating different thermal and optical performance. And by using EnergyPlus v8.1 and Window v7.2 program, we quantitatively analyzed cooling loads + lighting loads, thermal comfort and visual comfort in an office building installed with the glazing and shading devices. Result: Consequently, Case 9(Double Low-E+Exterior Blind) is the best arrangement of solar heat gain and daylight influx, thereby becomes the most excellent case of reducing cooling+lighting loads(46.8%) and simultaneously becomes the enhancement case in thermal comfort. Also, DGI(Daylight glare index) under clear sky conditions in summer was evaluated to be 19.6, and thereby satisfied the recommendation level of allowing visual comfort.

열량법을 이용한 초전도 케이블 냉각시스템의 열침입량 측정 (Measurement of Superconduct Cable Cooling System Heat Invasion by Calorimetry)

  • 김도형;김익생;김춘동;고득용;염한길
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.313-315
    • /
    • 2003
  • The heat loads invaded from the environment to several parts of superconduct cable cooling system were measured by liquid boiloff calorimetry. The measuring system was verified by the measurement to a uniform heat loads. The heat loads by the tubes for relief and pressure gauges were greater than the estimated.

  • PDF

RC 대형 냉각탑 셀의 손상추정에 관한 연구 (A Study on Damage-Assessment of RC Large Cooling Tower Shells)

  • 노삼영
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 한국공간정보시스템학회 2004년도 춘계 학술발표회 논문집 제1권1호(통권1호)
    • /
    • pp.279-286
    • /
    • 2004
  • An accumulated crack damage which propagates progressively with time was frequently observed on several engineering structures, This paper numerically demonstrates this damage process on large cooling tower shells under thermal and wind loads. Damage states under varying loads are investigated and the influence of this progressive damage process on the life-cycle of cooling towers discussed. The paper presents briefly some fundamentals of the geometrically and physically non-linear numerical analysis employed for reinforced concrete, especially concerning the models used for concrete, steel reinforcement and the bond between them. As a numerical example an existing cooling tower with noticeable meridian crack damage is analysed. The existing damage state of the cooling tower is determined by quasi-static analyses for temperature, hygric and cyclic wind leading. The change in the dynamical behaviour of the structure as mirrored in its natural frequencies and mode shapes is presented and discussed. Finally, the example shows that such damage processes develop progressively over the life-time of the structures.

  • PDF

연 최대 냉방부하의 간접추정 방법론에 관한 연구 (A Study on Indirect Estimating Methods for Yearly Maximum Cooling Load)

  • 양문희
    • 산업공학
    • /
    • 제16권1호
    • /
    • pp.16-26
    • /
    • 2003
  • In Korea, cooling power load, which occupies about 20% of peak load in 2000 and fluctuates depending on the popular usage of air conditioning systems, has been recently the focus of the load management. The first work of KEPCO (Korea Electric Power Corporation) to regulate cooling load as low as possible was to estimate its approximate scale and to develop the indirect methods to estimate it from the available time series data for the average hourly loads. However, KEPCO would like to have their methods improved both theoretically and practically. In this paper, we analyze their current indirect methods and detect their faults to design better indirect estimation methods. Under one of the assumptions of "no cooling load in April or May", the linear relationship between basic loads and GDP's, and the normalized seasonal factors of the Winters' multiplicative seasonal model, we provide ten indirect estimation methods in total and suggest the estimated cooling load(1988-1999) based on our various indirect methods.

온도, 습도 및 냉방부하 예측에 관한 연구 (A Study on the Estimation of Temperature, Humidity and Cooling Load)

  • 유성연;한승호;이제묘;한규현;노관종
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.80-85
    • /
    • 2006
  • The peak demand of electricity in summer season mainly comes from the day time cooling loads. Ice thermal Storage System (ITSS) uses off-peak electricity at night time to make ice for the day time cooling. In order to maximize the use of cold storage in ITSS, the estimation of day time cooling load for the building is necessary. In this study, we present a method of cooling load estimation using 5 years of normalized outdoor temperature, relative humidity, and the building construction data. We applied the hourly-based estimation to a general hospital building with relatively less sudden heat exchange and the results are compared with the measured cooling load of the building. The results show that the cooling loads estimation depends on the indoor cooling design temperature of the building.

  • PDF

화순화력발전소 주변해역의 온배수 환경용량 산정 (The Estimation of Marine Environmental Capacity for the Reception of Cooling Water from HTPP in Southern Waters of Cheju Island using a 3-D Hydrodynamic Model)

  • 김광수;최영찬;이문진
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제3권3호
    • /
    • pp.3-12
    • /
    • 2000
  • 제주도 남부해역을 대상으로 1997년부터 1999년까지 매달 현장 조사시 수온을 측정하였으며, 3차원 유체역학 수치모델을 이용한 시뮬레이션을 통하여 수온 분포를 재현하였다. 대상해역내에서 화순화력발전소로부터 배출되는 온배수의 열부하를 수용하기 위한 해양환경용량을 산정하기 위하여, 3차원 유체역학 수치모델을 이용하여 화력발전소 온배수의 열부하를 정량적으로 조절함으로써 해양생물에게 부적합한 수온 변화가 나타나는 환경 악화 현상을 예측하는 시뮬레이션을 실행하였다. 화순화력발전소가 하계에 35.9℃의 온배수를 112,800m³/day의 배출량으로 바다에 방류하고 있는 현재의 상태를 기준으로 하여 예측한 시뮬레이션 결과, 발전소 온배수의 열부하가 증가할수록 발전소 주변해역의 수온은 더욱 상승하는 것으로 나타났다. 발전소 온배수의 열부하가 현재 부하의 약 5배로 증가하는 경우, 발전소 주변 연안해역에서의 수온은 하계의 현재 수온보다 0.5℃만큼 상승하는 것으로 계산되었다. 화순화력발전소로부터 배출되는 온배수의 열부하를 수용하기 위한 제주도 남부연안해역의 해양환경용량은 현재 열부하의 약 5배에 해당하는 약 530×10/sup 6/kcal/day로 산정되었다. 이러한 해양환경용량은 발전소 온배수의 배출량이 112,800m³/day로 일정하게 유지되면서 온배수의 온도가 현재의 35.9℃로부터 그의 2배가 되는 71.8℃로 증가하는 경우에 해당하거나 또는 발전소 온배수의 온도가 35.9℃로 일정하게 유지되면서 온배수의 배출량이 현재의 112,800m³/day로부터 그의 4.6배가 되는 521,800m³/day로 증가하는 경우에 해당한다. 530×10/sup 6/kcal/day의 동일한 열부하를 기준으로 하여, 단지 온배수 배출량만 증가하는 경우와 단지 온배수 온도만 증가하는 경우를 비교하면, 온배수 배출량만 증가하는 경우가 온배수 온도만 증가하는 경우보다 방류해역의 수온을 좀더 상승시키고, 열부하의 영향을 받는 해역 범위를 좀더 확장시키는 것으로 예측되었다.

  • PDF