• Title/Summary/Keyword: conversion loss

Search Result 732, Processing Time 0.031 seconds

A Study of the Operation Characteristics of the Resonant Dual Converters (공진형 듀얼컨버터의 동작특성에 관한 고찰)

  • 양승학
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.4
    • /
    • pp.1-10
    • /
    • 1997
  • Resonant dual converters are remarkable as circuit topologies that can realize a power conversion on the high switching frequency with low switching loss. In this paper, bi-directional resonant power conversion system is established, which makes the powering and the regeneration possible, by loading an induction motor. For its practical use, the operation characteristics of the system are to be examined through a series of experiments. The characteristics are : (l)input/output, (2)resonants. (3)tum-off and zero voltage in the main devices and clamp device. By examining the measured waveforms, this study will investigate some problems in the system, and also give some suggestions for a further study.

  • PDF

Theoretical and experimental analysis of a venting clip to reduce stray inductance in high-power conversion applications

  • Jang, Hyun Gyu;Jung, Dong Yun;Kwon, Sungkyu;Cho, Doohyung;Park, Kun Sik;Lim, Jong-Wong
    • ETRI Journal
    • /
    • v.43 no.6
    • /
    • pp.1103-1112
    • /
    • 2021
  • In this study, we present a venting clip for high-power applications that is intended to reduce stray inductance. To reduce the stray inductance of packages in high-power applications, the proposed venting clip features slots are inserted onto a conventional clip. A conventional clip and the proposed venting clip were designed and fabricated to compare the respective stray inductance. The inductance of the proposed venting clip was approximately 15.8% than that of the conventional clip at a frequency of 100 kHz. Through a comparison between the conventional and venting clips, it is confirmed that the proposed venting clip is superior for high-power applications in terms of decreasing inductance. With reduced inductance, the switching-loss for such applications is also expected to decrease. Moreover, the impedance of the venting clip decreased by approximately 15.5% compared with that of the conventional clip at a frequency of 100 kHz. The venting clip, which has reduced resistive component, is also expected to decrease conduction loss in highpower applications.

Design of Double-Conversion Down Mixer Using Single Half-LO Frequency at 2.3 GHz (2.3 GHz 대역에서 단일 Half-LO 주파수를 이용한 Double-Conversion Down Mixer 설계)

  • Kim Min-Seok;Moon Ju-Young;Yun Sang-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.8 s.111
    • /
    • pp.719-724
    • /
    • 2006
  • In this paper, we designed the double conversion down mixer by using Half-LO frequency in 2.3 GHz band. The IF frequency is obtained by supplying two LO frequencies to HEMT in both gate type and resistive type. The proposed mixer uses Half-LO frequency the same way as conventional sub-harmonic mixers. However the proposed one uses fundamental component of Half-LO frequency in first stage instead of using second harmonic components of Half-LO frequency, and the IF frequency is obtained by resistive type mixer in second stage, thereby the proposed mixer can improve linearity in comparison with conventional active mixer. We can verify that the proposed mixer has an conversion loss of 5dBm and IIP3 of 16.25dBm by using 10 dBm Power.

Design and fabrication of power detector for multi-band six-port direct conversion method (다중대역 6단자 직접변환 방식을 위한 전력 검파기 설계 및 제작)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2194-2200
    • /
    • 2010
  • In this paper, the power detectors using metamaterials were designed and fabricated for multi-band six-port direct conversion method. The RF short-stubs for power detector were designed by using metamaterials which provide multi-band characteristics. The power detectors with metamaterial RF short-stub were analyzed and fabricated by using lumped and distributed element. The measured results of metamaterial power detectors show the good agreement with the simulation results. The performance of lumped-metamaterial RF short-stub shows the insertion loss below 1 dB and the good frequency response characteristics. Also, the distributed-metamaterial RF short-stub shows the good frequency response characteristics and the insertion loss under that of lumped-metamaterial RF short-stub. The multi-band power detectors with metamaterial RF short-stub detect the input RF signal in the designed dual frequency bands very well.

Single-Power-Conversion Series-Resonant AC-DC Converter with High Efficiency (고효율을 갖는 단일 전력변환 직렬 공진형 AC-DC 컨버터)

  • Jeong, Seo-Gwang;Cha, Woo-Jun;Lee, Sung-Ho;Kwon, Bong-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.224-230
    • /
    • 2016
  • In this study, a single-power-conversion series-resonant ac-dc converter with high efficiency and high power factor is proposed. The proposed ac-dc converter consists of single-ended primary-inductor converter with an active-clamp circuit and a voltage doubler with series-resonant circuit. The active-clamp circuit clamps the surge voltage and provides zero-voltage switching of the main switch. The series-resonant circuit consists of leakage inductance $L_{lk}$ of the transformer and resonant capacitors $ C_{r1}$ and $ C_{r2}$. This circuit also provides zero-current switching of output diodes $D_1$ and $D_2$. Thus, the switching loss of switches and reverse-recovery loss of output diodes are considerably reduced. The proposed ac-dc converter also achieves high power factor using the proposed control algorithm without the addition of a power factor correction circuit and a dc-link electrolytic capacitor. A detailed theoretical analysis and the experimental results for a 1kW prototype are discussed.

Optimum Conditions for Glycoside Conversion to Aglycone by ${\gamma}-Galactosidase$ (유당분해효소에 의한 Glycoside의 Aglycone으로 전환을 위한 최적 조건 확립)

  • Kim, Nam-Chul;Jeon, Byung-Ju;Ahn, Joung-Jwa;Kwak, Hae-Soo
    • Food Science of Animal Resources
    • /
    • v.27 no.3
    • /
    • pp.329-336
    • /
    • 2007
  • This study was designed to find the optimum conditions for converting isoflavone glycoside to aglycone by ${\beta}-galactosidase$. Three different forms of the enzyme were tested and the optimum enzyme concentration, incubation temperature, pH, and incubation time were determined. Before treatment with enzyme, isoflavone contained 89.4% glycoside including daidzin, glycitin and genistin, and only 10.6% aglycone including daidzein, glycitein and genistein. Among the enzymes tested, the highest rate of isoflavone hydrolysis to aglycone, 35%, was observed when 3 unit/g Fungal Lactase (Amano Enzyme) was used. Higher incubation temperatures resulted in a higher rate of hydrolysis along with a greater loss of isoflavone mass. Therefore, body temperature $(37^{\circ}C)$ may be adequate for isoflavone conversion, with 44.9% hydrolysis and less than 10% loss of mass. As expected, a higher amount of aglycone was produced at pH 7 compared with other pH values. During 5hr of incubation, the conversion of glycoside to aglycone increased dramatically from 0 to 1hr, and plateaued thereafter. In addition, commercial soy-based milk was hydrolyzed more effectively with ${\beta}-galactosidase$ when incubated for 5hr. Based on the above results, the optimum conditions for isoflavone hydrolysis by ${\beta}-galactosidase$ were for 3 hr at $37^{\circ}C$, pH 7 with 3 unit/g Fungal Lactase (Amano Lactase), yielding an average total amount of aglycone ranging from 40 to 47%.

Analysis of conducted noise on modeling methods for loss of contact during traction of high-speed rail vehicle (고속전철 주행시 이선현상 모델링 방법에 따른 전도성 노이즈 해석)

  • Kim, Jae-Moon;Kim, Yang-Soo;Chang, Chin-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.72-75
    • /
    • 2008
  • The Electromagnetic Interference(EMI) in railway applications is largely due to doing the power conversion for traction and Auxiliary system on the Highspeed Electric Multiple Unit-400X(HEMU-400X). In order to research on EMI in railway applications, it were included how much the HEMU-400X generates it and it has an effect on the equipments of electric system which resulted from Power Line Disturbance (PLD) phenomenon by the loss of contact during its running. In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated. The analysis of the loss of contact based on Power Simulator program software is performed to develop power line disturbance model suitable for high speed operation. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system.

  • PDF

Novel Zero-Current-Switching (BCS) PWM Switch Cell Minimizing Additional Conduction Loss

  • Park, Hang-Seok;Cho, B.H.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.12B no.1
    • /
    • pp.37-43
    • /
    • 2002
  • This paper proposes a new zero-current switching (ZCS) pulse-width modulation (PWM) switch cell that has no additional conduction loss of the main switch. In this cell, the main switch and the auxiliary switch turn on and turn off under zero current condition. The diodes commutate softly and the reverse recovery problems are alleviated. The conduction loss and the current stress of the main switch are minimized, since the resonating current for the soft switching does not flow through the main switch. Based on the proposed ZCS PWM switch cell, a new family of dc to dc PWM converters is derived. The new family of ZCS PWM converters is suitable for the high power applications employing IGBTs. Among the new family of dc to dc PWM converters, a boost converter was taken as an example and has been analyzed. Design guidelines with a design example are described and verified by experimental results from the 2.5㎾ prototype boost converter operating at 40KHz.

Fabrication and Characterization of the Transmitter and Receiver Modules for Free Space Optical Interconnection (자유공간 광연결을 위한 송수신 모듈의 제작및 성능 분석)

  • 김대근;김성준
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.12
    • /
    • pp.16-22
    • /
    • 1994
  • In this paper, transmitter and receiver modules for free space optical interconnection are implemented and characterized. In the transmitter module, bias circuitry which inject current into the direct modulated laser diode is fabricated and in the receiver module, p-i-n diode is integrated with an MMIC amplifying stage. Laser diode has a direct-modulated bandwidth of 2 GHz at 1.4 Ith bias while p-i-n diode and amplifying stage has a bandwidth of 1.3 GHz and 1.5 GHz, repectively. Optical interconnection has a bandwidth of 1.3 GHz and linearly transmit modulated voltage signal up to 1.5 Vp-p. Measured loss of optical interconnection is 5dB which is composed of optoelectronic conversion loss of 15 dB, electrical impedance mismatch loss of 6.7 dB in transmitter module and gain of 18 dB in receiver module. Seperation between transmitter and receiver can be extended up to 50 cm by using a lens.

  • PDF

Undergoing Noninvasive Mechanical Ventilation (비침습적 인공호흡기 적용 환자의 불편감 연구)

  • Shin, Hyun-Ja
    • Journal of Korean Critical Care Nursing
    • /
    • v.2 no.1
    • /
    • pp.69-80
    • /
    • 2009
  • Purpose: The purpose of this preliminary study was to describe the physical and psychosocial distress of critically ill patients undergoing noninvasive ventilation(NIV). Method: Open-ended question interviews were conducted with four patients using NIV. Considering the outcomes of the interviews, literature, and experts'opinions, a survey questionnaire was developed. Twenty patients in medical and surgical intensive care units answered the questions. Results: Through open-ended question interviews and survey, the patients using NIV reported feeling heavy, impotent feeling, pain, loss in feeling, loss in communication, and lack of sleep as physical distress and a loss in sense of time, pain, anxiety, mind of desiring to die, worry about family, and a sense of burden for medical-cure expenses as psychosocial distress. Conclusion: Critically ill patients undergoing NIV experience physical and psychosocial distress to artificial respiratory ventilation treatment. Further research should be performed with a large sample for generalization of the study result.

  • PDF