• Title/Summary/Keyword: convergence technology

Search Result 15,550, Processing Time 0.042 seconds

A Study on the Analysis of Difference between IT and Non-IT Companies on the Smart Work Environment Continuous Use Intention - Focusing on Korean Small and Medium Enterprises (스마트워크 환경에서 지속사용의도에 대하여 IT기업과 비IT기업 간의 차이분석에 관한 연구 -한국 중소기업을 중심으로)

  • Jung, Soo-Yong;Shin, Yong-tae
    • Journal of Digital Convergence
    • /
    • v.16 no.3
    • /
    • pp.249-259
    • /
    • 2018
  • This research had intended to find out regarding the present influences of the Smart Work on the intention to use continuously with the staff members working in the small- and medium-sized enterprises as the subject. And, finally, it had intended to find out about the Smart Work environments of the IT corporations and the non-IT corporations. For this research, the questionnaire survey data were collected from the staff members working at the small- and medium-sized enterprises. Through the questionnaire survey data that were collected, an empirical analysis was carried out. And, through the reliability analysis, the feasibility analysis, the discriminatory feasibility analysis, and the inspection of the degree of suitableness of the structural equation model, finally, the research model was verified and, finally, a difference analysis of the IT corporations and the non-IT corporations was carried out. Regarding the results of the analysis of the research, it appeared that the factors of the job efficiency and the job autonomy of the special characteristics of the job had the positive influences on the usefulness and the job satisfaction, which were the parameters and which were perceived. And it appeared that the time flexibility of the job form could not have any influences on the usefulness and the job satisfaction, which were the parameters and which were perceived. And it appeared that the spatial flexibility had the influences on the job satisfaction only. The perceived usefulness, which was a parameter, had the positive influences on the job satisfaction and the intention to use continuously. And, finally, the job satisfaction had the positive influences on the intention to use continuously. And it appeared that there were the differences, too, between the IT corporations and the non-IT corporations. It is thought that, through the results of this research and through the Smart Work environment, the positive influences on the workers and the organizations could be induced and that a better working environment than previously can be provided to the workers to fit the special characteristics of the corporations.

Comparison of In Vitro Lipid Deposition and Change of Optical Characteristics on Daily Disposable Lenses (1-day) and 3-days Lenses Over 3 days (3-days lenses와 daily disposable lenses(1-day)의 착용 시간 별 지방 침착량 및 광학적 특성 변화의 비교)

  • Song, Sun Jung;Lee, Su Yeon;Kim, Ki Hong;Chu, Byoung Sun
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.2
    • /
    • pp.67-73
    • /
    • 2020
  • The study aimed to investigate in vitro lipid deposition of oleic acid, oleic acid methyl ester and cholesterol on a daily disposable (1-day lenses) and 3-days lenses over 3 days and changes of optical characteristics is also investigated. Artificial tear solutions were prepared to simulate actual tear compositions. Two types of contact lenses (1-day lenses (Senofilcon A) and 3-days lenses (silicone tripolymer)) were soaked in the artificial tear solutions within an incubator at 37 ℃ with 150 rpm for 8, 16, 24 hours. Lipid deposition (oleic acid, oleic acid methyl ester and cholesterol) were measured using high performance liquid chromatography (HPLC) instrument. In addition, measurements of oxygen transmissibility, light transmittance and observation of lens surface were conducted. The amount of lipid deposition on the 1-day lenses were 127.55 ㎍/lens for Day 1, 302.96 ㎍/lens, for Day 2, and 353.30 ㎍/lens for Day 3. The 3-days lenses were 46.22 ㎍/lens for Day 1, 66.07 ㎍/lens for Day 2, and 67.45 ㎍/lens for Day 3. Oxygen transmissibility were 81×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 48×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 1-day lenses, it were 13.23×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 9.6×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 3-days lenses. Transmittance of each lenses were 97.21% (Baseline) and 94.25% (Day 3) for the 1-day lenses, 97.65% (Baseline) and 95.15% (Day 3) for the 3-days lenses. Observation of surface deposition indicated greatest deposition for the 3-days lenses type on Day 3. Lipid deposition for both lens types increased by day and was greater for the 1-day lenses type. Surface deposition appeared to differ as it was greatest for the 3 days lens type, which may suggest other deposits such as protein may be present.

Evaluation of Attenuation Rate Error on Skin Dosimeter using Monte Carlo Simulation in Photon and Electron Beam Therapy (광자선 및 전자선 치료에서 피부선량계의 측정과 시뮬레이션을 이용한 감약률 오차 평가)

  • Han, Moo-Jae;Yang, Seung-Woo;Heo, Seung-Uk;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.841-848
    • /
    • 2020
  • In the field of radiation therapy using photon beams and electron beams, since each patient has a different sensitivity to radiation, skin side effects may occur even at the same dose. Therefore, if there is a risk of excessive dose to the skin, a dosimeter is attached to verify whether the correct dose is being investigated. However, since the skin dosimeter checks the attachment site visually by measuring a point dose, it is difficult to confirm an accurate dose distribution. As a result, the measurement and simulation errors of the material HgI2 in the 6 MV photon beam were 3.73% and 5.24%, respectively, at the minimum thickness of 25 ㎛, and the material PbI2 was 4.73% and 5.65%, respectively. On the other hand, as a result of the 6 MeV electron beam, the measurement and simulation errors of the material HgI2 were 1.35% and 1.12%, respectively, at a minimum thickness of 25 ㎛, and the material PbI2 showed relatively low attenuation error, 1.67% and 1.20%, respectively. Therefore, it was evaluated that the thickness of the photon beam within 25 ㎛ and the electron beam within 100 ㎛ is suitable to have a reduction rate error within 5%. This study presents a new research direction for a flexible dosimeter attached to the human body that is required in clinical practice and the construction conditions of a future skin dosimeter.

Bioequivalence Evaluation of Two Cefquinome 2.5% Injectable Products in Piglets (돼지에서 두 가지 Cefquinome 2.5% 제제의 생물학적 동등성 평가)

  • Song, In-Bae;Kim, Tae-Won;Lee, Hong-Gee;Kim, Myoung-Seok;Hwang, Youn-Hwan;Park, Byung-Kwon;Lim, Jong-Hwan;Yun, Hyo-In
    • Journal of Veterinary Clinics
    • /
    • v.29 no.3
    • /
    • pp.233-236
    • /
    • 2012
  • Cefquinome, a fourth generation cephalosporin, has been solely used for veterinary medicine and has a broad antibacterial spectrum against gram-negatives and gram-positives being very stable to ${\beta}$-lactamases. This study was conducted to evaluate the bioequivalence of two cefquinome 2.5% products in piglets. Plasma cefquinome concentrations were analyzed by liquid chromatography-mass spectrometry (LC/MS). Mean maximum concentration ($C_{max}$) of test product ($Cequus^{(R)}$) and reference product ($Cobactan^{(R)}$) were $4.34{\pm}0.58$ and $4.22{\pm}0.47{\mu}g/mL$, and mean area under the concentration time curve ($AUC_{0{\rightarrow}{\infty}}$) values were $10.43{\pm}1.96$ and $10.25{\pm}2.98{\mu}g{\cdot}h/mL$, respectively. The 90% confidence intervals for the ratio of $C_{max}$ (0.941-1.115), and $AUC_{0{\rightarrow}{\infty}}$ (0.927-1.172) values for the test and reference products were within the acceptable bioequivalence limit of 0.80-1.25. It is concluded that two commercial cefquinome injectable solutions are bioequivalent in their extent of drug absorption in piglets.

Pressure Drop Predictions Using Multiple Regression Model in Pulse Jet Type Bag Filter Without Venturi (다중회귀모형을 이용한 벤츄리가 없는 충격기류식 여과집진장치 압력손실 예측)

  • Suh, Jeong-Min;Park, Jeong-Ho;Cho, Jae-Hwan;Jin, Kyung-Ho;Jung, Moon-Sub;Yi, Pyong-In;Hong, Sung-Chul;Sivakumar, S.;Choi, Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.2045-2056
    • /
    • 2014
  • In this study, pressure drop was measured in the pulse jet bag filter without venturi on which 16 numbers of filter bags (Ø$140{\times}850{\ell}$) are installed according to operation condition(filtration velocity, inlet dust concentration, pulse pressure, and pulse interval) using coke dust from steel mill. The obtained 180 pressure drop test data were used to predict pressure drop with multiple regression model so that pressure drop data can be used for effective operation condition and as basic data for economical design. The prediction results showed that when filtration velocity was increased by 1%, pressure drop was increased by 2.2% which indicated that filtration velocity among operation condition was attributed on the pressure drop the most. Pressure was dropped by 1.53% when pulse pressure was increased by 1% which also confirmed that pulse pressure was the major factor affecting on the pressure drop next to filtration velocity. Meanwhile, pressure drops were found increased by 0.3% and 0.37%, respectively when inlet dust concentration and pulse interval were increased by 1% implying that the effects of inlet dust concentration and pulse interval were less as compared with those changes of filtration velocity and pulse pressure. Therefore, the larger effect on the pressure drop the pulse jet bag filter was found in the order of filtration velocity($V_f$), pulse pressure($P_p$), inlet dust concentration($C_i$), pulse interval($P_i$). Also, the prediction result of filtration velocity, inlet dust concentration, pulse pressure, and pulse interval which showed the largest effect on the pressure drop indicated that stable operation can be executed with filtration velocity less than 1.5 m/min and inlet dust concentration less than $4g/m^3$. However, it was regarded that pulse pressure and pulse interval need to be adjusted when inlet dust concentration is higher than $4g/m^3$. When filtration velocity and pulse pressure were examined, operation was possible regardless of changes in pulse pressure if filtration velocity was at 1.5 m/min. If filtration velocity was increased to 2 m/min. operation would be possible only when pulse pressure was set at higher than $5.8kgf/cm^2$. Also, the prediction result of pressure drop with filtration velocity and pulse interval showed that operation with pulse interval less than 50 sec. should be carried out under filtration velocity at 1.5 m/min. While, pulse interval should be set at lower than 11 sec. if filtration velocity was set at 2 m/min. Under the conditions of filtration velocity lower than 1 m/min and high pulse pressure higher than $7kgf/cm^2$, though pressure drop would be less, in this case, economic feasibility would be low due to increased in installation and operation cost since scale of dust collection equipment becomes larger and life of filtration bag becomes shortened due to high pulse pressure.

Physicochemical Composition of Buckwheat Microgreens Grown under Different Light Conditions (다른 광조건 하에서 재배된 메밀 새싹채소의 이화학적 특성)

  • Choi, Mi-Kyeong;Chang, Moon-Sik;Eom, Seok-Hyun;Min, Kwan-Sik;Kang, Myung-Hwa
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.5
    • /
    • pp.709-715
    • /
    • 2015
  • As consumers interest in microgreens is increasing worldwide, the production of leafy microgreens uisng different LED lights was investigated in this study. The experiment was carried out to evaluate the effects of different LED lights on the composition and vitamin C contents of buckwheat microgreens. Physicochemical properties of buckwheat microgreens grown under different lights (red, blue, and white) and control exposed to a dark room were investigated. Moisture contents of buckwheat microgreens were 95.65% under white light (WL), 95.75% under blue light (BL), 90.77% under red light (RL), and 89.71% under dark room (DR). Crude ash contents of buckwheat microgreens grown under WL, DR, RL, and BL were 0.39%, 0.39%, 0.31%, and 0.37%, respectively. Crude protein contents of buckwheat microgreens grown under DR, RL, WL, and BL were 7.12%, 7.81%, 1.60%, and 2.40%, respectively. Crude fat contents of buckwheat microgreens grown under DR, BL, RL, and WL were 1.12%, 0.54%, 0.35%, and 0.22%, respectively. $^{\circ}Brix$ was the highest in microgreens grown under BL and RL and the lowest in buds grown under DR. Vitamin C content was the highest in buds grown under WL and the lowest in buds grown under BL. Total chlorophyll content was the highest in microgreens grown under RL and the lowest in buds grown under WL. For mineral content measurement of buckwheat microgreens, Ca, K, Mg, and P contents were high whereas B, Cu, and Zn contents were not detected. The mineral contents of buckwheat microgreens according to each color of light showed significant differences. These results demonstrated that treatment of different colored LED lights during cultivation was able to increase vitamin C content up to affecting the nutritional value of buckwheat microgreens.

Effect of Endoscopic Forceps on the Quality of Duodenal Mucosal Biopsy in Healthy Cats (고양이 십이지장 점막 생검 시 내시경 생검 겸자가 조직의 질에 미치는 영향에 관한 연구)

  • Won, Jin-Hee;Hong, Il-Hwa;Jang, Hyo-Mi;Eom, Na-Young;Jee, Cho-Hee;Jung, Hae-Won;Kang, Byeong-Teck;Jeong, Dong Wook;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.32 no.2
    • /
    • pp.141-147
    • /
    • 2015
  • Based on the results of previous studies, endoscopic biopsy sample's quality has a major impact on its adequacy for histopathology, and that the nature of the biopsy forceps can influence the specimen quality. The present study compared the effects of three different types of endoscopic biopsy forceps and two different operators on sample quality and adequacy for histopathology in three healthy cats. Every biopsy was performed between the major papilla and caudal duodenal flexure, and each operator performed five biopsies with each type of forceps on each cat, for a total of 90 biopsies. One pathologist evaluated the quality and adequacy of the obtained samples. Biopsies performed with large-cup forceps provided heavier and longer samples than the standard round forceps. With the same size forceps, the presence of alligator teeth had no effect on sample quality or adequacy for histopathological examination and assessment. Based on the results of the present study, although the standard round forceps could be used to obtain adequate samples for histopathology, large-cup forceps such as the standard oval and alligator jaw type have the advantage of obtaining high quality endoscopic samples.

Family Caregivers' Quality of Life, Depression and Anxiety according to Symptom Control in Hospice Patients (호스피스 환자의 증상조절에 따른 가족간병인의 삶의 질과 우울, 불안)

  • Kim, Yun Hee;Lee, Seung Hun;Lim, Ho Seop;Choi, Young Jin;Kim, Yun Jin;Lee, Sang Yeoup;Lee, Jeong Gyu;Jeong, Dong Wook;Yu, Kyoung Hwa
    • Journal of Hospice and Palliative Care
    • /
    • v.18 no.4
    • /
    • pp.314-321
    • /
    • 2015
  • Purpose: It is well known that a terminal cancer condition affects not only patient themselves but their family members because the patients experience a variety of symptoms. This study was aimed to investigate modifiable factors that influence family caregivers' quality of life, depression, and anxiety. Methods: From January 2015 through May 2015, a survey was conducted with 61 family caregivers of hospice patients who were hospitalized in two university hospitals and one municipal hospital in Busan. The questionnaire was consisted of characteristics of family caregivers and patients, the Korean version of the Caregiver Quality of Life Index-Cancer (CQOLC-K), Beck's Depression Inventory II (BDI-II), Beck's Anxiety Inventory (BAI), and patient's symptom controlling scores rated by family caregivers. Results: Family caregivers' depression was associated with religion. Quality of life and depression of family caregivers were also influenced by monthly household income. Patient age was inversely related to family caregiver's quality of life ($r_s=-0.259$, P=0.043). Family caregivers' quality of life was associated with patient's anxiety (r=0.443, P=0.001). Family caregivers' depression was affected by patient's constipation (r=0.276, P=0.046), anxiety (r=0.508, P<0.001), and daytime drowsiness (r=0.377, P=0.005). And family caregivers' anxiety was influenced by patients' sleep disturbance (r=0.276, P=0.046), depression (r=0.297, P=0.031), and anxiety (r=0.357, P=0.009). Conclusion: According to our findings, family caregivers had higher quality of life and less depression and anxiety when symptoms in hospice patients were well controlled.

History of 20 years since establishments of the Korean Geophysical Society and the Korean Society of Exploration Geophysicists and 10 years since integration as the Korean Society of Earth and Exploration Geophysicists (대한지구물리학회와 한국물리탐사학회의 설립 20 년, 한국지구물리·물리탐사학회로의 통합 10 년의 역사)

  • Lim, Mutaek;Jin, Young Keun;Lee, Joohan;Choi, Jihyang
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.4
    • /
    • pp.241-267
    • /
    • 2017
  • Since the liberation in 1945, Korean specialists in the field of geological science and mineral resources engineering have developed two disciplines through the cooperation and competition with each other. Specialists both in the geophysics and in the geophysical exploration, who share much, have developed their own fields deeper and broader. Since the late 1990s, specialists in both fields felt the need for an independent society to deal with their fields and discussed the establishment of such a society. In 1997, they discussed to establish a unified society which integrates both fields instead of separated societies. However, in 1998, the Korean Geophysical Society and the Korean Society of Exploration Geophysicists were separately established due to some practical problems. During 7 ~ 8 years since the establishment of the two societies, many members of the two societies intended that the two societies should integrate into a single comprehensive society based on the facts that many fields of each society are overlapped and naturally many members of one society are the members of the other society. The leaders of the two societies accepted these opinions also and began to discuss thoroughly the integration from 2005. Eventually, in 2007, the two societies successfully integrated and established the Korean Society of Earth and Exploration Geophysicists. The Korean Society of Earth and Exploration Geophysicists continues to cooperate and compete with other societies of geological science and mineral resources engineering in Korea and in circumpacific area including Asia, Oceania and Americas, contributing to the development of geophysics and geophysical exploration.

Evaluation of free radical scavenging and pancreatic lipase inhibitory effects of Aquilaria agallocha extracts (침향 추출물의 라디칼 및 췌장 지방분해 효소저해 활성 평가)

  • Lee, Ha Yeong;Lee, In-Chul;Kwak, Jae Hoon;Kim, Tae Hoon
    • Food Science and Preservation
    • /
    • v.22 no.3
    • /
    • pp.437-442
    • /
    • 2015
  • In a continuing screening of selected medicinal plants native to South Korea, the antioxidant and pancreatic lipase inhibitory activities of an aqueous methanolic extract from the heartwood of Aquilaria agallocha were investigated. Eighty percent of the methanolic extract of A. agallocha was further divided into $CH_2Cl_2$, EtOAc and n-BuOH in order to yield four solvent-soluble portions, namely $CH_2Cl_2$-soluble, EtOAc-soluble, n-BuOH-soluble and $H_2O$ residue. The antioxidant properties were evaluated by employing radical scavenging assays using 1,1-diphenyl-2-picrylhydrazyl (DPPH) and 2,2'-azino-bis (3-ethylbenzothiazoline-6-sulphonic acid) ($ABTS^+$) radicals, while the anti-obesity efficacy of A. agallocha extracts and solvent-soluble portions were tested by porcine pancreatic lipase assay. All tested samples showed dose-dependent radical scavenging and pancreatic lipase inhibitory activities. Among the tested extracts and solvent-soluble portions, the $CH_2Cl_2$-soluble portion showed much higher radical scavenging activity and pancreatic lipase inhibitory properties when compared with other solvent-soluble portions. This result suggested that there was a significant relationship between the total phenolic content and biological efficacies, and A. agallocha extract might be considered as a new potential source of natural antioxidants and as a pancreatic lipase inhibitory source. A more systematic investigation of this biomass will be performed for further investigation of activity against antioxidative and anti-obesity effects.